Product catalog summary
Overview: This document outlines the specifications and guidelines for gauge valves and instrumentation manifolds, focusing on the GV, GVH, and GR series, as well as 2-valve, 3-valve, and 5-valve manifolds. It includes details on types, dimensions, materials, features, and pressure-temperature ratings.
Types and Dimensions: Manifolds are categorized into remote mount and direct mount types, with distinctions based on flange types such as coplanar, traditional, kidney, and eccentric. The document also covers bleed valves, calibration fittings, and manifold bracket supports.
Materials and Construction: Standard materials include 316 SS/A479, 304 SS/A479, and zinc-plated carbon steel, with compliance to NACE MR0175/ISO 15156 for sour gas service emphasized.
Features: Key features include non-rotating lower stem designs, safety back seating seals, rolled spindle threads, and externally adjustable glands. Valves are designed for low torque operation and offer options for different colored handles.
Pressure vs. Temperature: The GV and GR series can handle pressures up to 6000 psig, while the GVH series can handle up to 10000 psig. Temperature ranges vary based on packing and seat materials, with PTFE and graphite options available.
Testing and Standards: Each valve is leak tested with nitrogen or compressed air, and GVH series valves are tested with water at 1.1 times the maximum working pressure. Pressure-temperature graphs for different series are included.
Ordering Information: Detailed ordering information, including part numbers and descriptions, is provided to assist in selecting the appropriate valve configuration.
Additional Series Overview: The document also covers the EF Series (Eccentric) and KF Series, providing technical specifications and ordering information. It includes details on mounting manifolds, connection types, and dimensions.
Specifications: Basic ordering numbers for different series, including the EF and KF Series, are listed along with their connection types and sizes. Dimensions are provided in inches and millimeters.
Block and Bleed Valves: Several series of block and bleed valves, including BB, DB, SB, and DBB Series, are mentioned as essential for isolating and bleeding off pressure in instrumentation systems.
Calibration Fittings: Calibration fittings are highlighted for providing rapid access to cells for calibration purposes, noting that accessing the port of a DP transmitter requires the removal of the vent port tap.
Bleed Valves: The RB Series Bleed Valve is identified as a standard test/vent valve, with additional information available in the FITOK Bleed Valve RB Series catalog.
Contact Information: For further details, contact information for FITOK, including their website and email address, is provided.
See more

Catalog excerpts

Gauge Valves and Instrumentation Manifolds-1

Gauge Valves and Instrumentation Manifolds C-03 C-02 Gauge Valves and Instrumentation Manifolds Contents Gauge Valves Standard Materials of Construction Standard Materials of Construction Design Standards Manifolds Mount Application Remote Mount Manifolds Direct Mount Manifolds (transmitter with coplanar traditional flange) Direct Mount Manifolds (transmitter with normal traditional flange) Direct Mount Manifolds (transmitter without flange) Accessories Manifold Bracket Supports Kidney Flange/Eccentric Flange Bleed Valves Calibration Fittings Gauge Valves and Instrumentation Manifolds

 Open the catalog to page 1
Gauge Valves and Instrumentation Manifolds-2

Gauge Valves and Instrumentation Manifolds C-03 C-02 Gauge Valves and Instrumentation Manifolds Contents Gauge Valves Standard Materials of Construction Standard Materials of Construction Design Standards Manifolds Mount Application Remote Mount Manifolds Direct Mount Manifolds (transmitter with coplanar traditional flange) Direct Mount Manifolds (transmitter with normal traditional flange) Direct Mount Manifolds (transmitter without flange) Accessories Manifold Bracket Supports Kidney Flange/Eccentric Flange Bleed Valves Calibration Fittings Gauge Valves and Instrumentation Manifolds

 Open the catalog to page 2
Gauge Valves and Instrumentation Manifolds-3

C-04 Gauge Valves and Instrumentation Manifolds Gauge Valves and Instrumentation Manifolds C-05 Gauge Valves GV Series, GVH Series and GR Series ◎ Working pressure up to: Stainless steel: GV, GR series up to 6000 psig (414 bar) GVH series up to 10000 psig (690 bar) Pressure (psig) ◎ GV Series and GVH Series working temperature: PTFE packing: -65°F to 450°F (-54°C to 232°C) Graphite packing: -65°F to 1200°F (-54°C to 649°C) GR Series working temperature: Acetal seat: -20°F to 250°F (-28°C to 121°C) PEEK seat: -20°F to 400°F (-28°C to 204°C) ◎ Variety of materials for seat and packing ◎ Lubricant...

 Open the catalog to page 3
Gauge Valves and Instrumentation Manifolds-4

C-04 Gauge Valves and Instrumentation Manifolds Gauge Valves and Instrumentation Manifolds C-05 Gauge Valves GV Series, GVH Series and GR Series ◎ Working pressure up to: Stainless steel: GV, GR series up to 6000 psig (414 bar) GVH series up to 10000 psig (690 bar) Pressure (psig) ◎ GV Series and GVH Series working temperature: PTFE packing: -65°F to 450°F (-54°C to 232°C) Graphite packing: -65°F to 1200°F (-54°C to 649°C) GR Series working temperature: Acetal seat: -20°F to 250°F (-28°C to 121°C) PEEK seat: -20°F to 400°F (-28°C to 204°C) ◎ Variety of materials for seat and packing ◎ Lubricant...

 Open the catalog to page 4
Gauge Valves and Instrumentation Manifolds-5

Instrument Test/Vent Basic Ordering Number Inlet/Process Outlet/Instrument Vent stem Instrument Vent The dimensions shown are for GV series gauge valves. If you need the dimensions of GVH, GR series, please contact FITOK Group or our authorized distributors. Ordering Number Description Miniature Type Lagging extension body is inserted through pipe insulation. The dimensions shown are for GV series gauge valves. If you need the dimensions of GVH, GR series, please contact FITOK Group or our authorized distributors. Black Aluminum Bar Red R Aluminum Bar Plug Isolate Note: 1. Cleaning and Packaging:...

 Open the catalog to page 5
Gauge Valves and Instrumentation Manifolds-6

Instrument Test/Vent Basic Ordering Number Inlet/Process Outlet/Instrument Vent stem Instrument Vent The dimensions shown are for GV series gauge valves. If you need the dimensions of GVH, GR series, please contact FITOK Group or our authorized distributors. Ordering Number Description Miniature Type Lagging extension body is inserted through pipe insulation. The dimensions shown are for GV series gauge valves. If you need the dimensions of GVH, GR series, please contact FITOK Group or our authorized distributors. Black Aluminum Bar Red R Aluminum Bar Plug Isolate Note: 1. Cleaning and Packaging:...

 Open the catalog to page 6
Gauge Valves and Instrumentation Manifolds-7

C-08 Gauge Valves and Instrumentation Manifolds Gauge Valves and Instrumentation Manifolds C-09 Instrumentation Manifolds ◎ Working temperature: PTFE packing: -65° F to 450° F (-54° C to 232° C) Graphite packing: -65° F to 1200° F (-54° C to 649° C) ◎ Linear instead of rotary motion of the rising, non-rotating stem minimizes packing abrasion and reduces the friction between the seat and the tip ◎ Upper stem thread lubricant isolated from system media Pressure (psig) ◎ Two-piece stem design: Upper stem threads cold rolled and lower stem hardened for high strength and smooth operation ◎ Safety...

 Open the catalog to page 7
Gauge Valves and Instrumentation Manifolds-8

C-08 Gauge Valves and Instrumentation Manifolds Gauge Valves and Instrumentation Manifolds C-09 Instrumentation Manifolds ◎ Working temperature: PTFE packing: -65° F to 450° F (-54° C to 232° C) Graphite packing: -65° F to 1200° F (-54° C to 649° C) ◎ Linear instead of rotary motion of the rising, non-rotating stem minimizes packing abrasion and reduces the friction between the seat and the tip ◎ Upper stem thread lubricant isolated from system media Pressure (psig) ◎ Two-piece stem design: Upper stem threads cold rolled and lower stem hardened for high strength and smooth operation ◎ Safety...

 Open the catalog to page 8
Gauge Valves and Instrumentation Manifolds-9

C-10 Gauge Valves and Instrumentation Manifolds Gauge Valves and Instrumentation Manifolds C-11 ◎ Direct Mount Manifolds (transmitter with coplanar mounting flange) Manifolds Mounting Application ◎ Remote Mount Manifolds (with transmitter) Pressure transmitter Coplanar mounting flange Differential pressure transmitter Differential pressure transmitter Coplanar mounting flange Coplanar mounting flange Pressure transmitter Pressure transmitter Pressure transmitter ◎ Direct Mount Manifolds (transmitter with traditional flange) 2-valve manifolds Differential pressure transmitter Coplanar mounting...

 Open the catalog to page 9
Gauge Valves and Instrumentation Manifolds-10

C-10 Gauge Valves and Instrumentation Manifolds Gauge Valves and Instrumentation Manifolds C-11 ◎ Direct Mount Manifolds (transmitter with coplanar mounting flange) Manifolds Mounting Application ◎ Remote Mount Manifolds (with transmitter) Pressure transmitter Coplanar mounting flange Differential pressure transmitter Differential pressure transmitter Coplanar mounting flange Coplanar mounting flange Pressure transmitter Pressure transmitter Pressure transmitter ◎ Direct Mount Manifolds (transmitter with traditional flange) 2-valve manifolds Differential pressure transmitter Coplanar mounting...

 Open the catalog to page 10

All FITOK GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.