Type R632A Integral Two-Stage Regulator - 1

Type R632A Integral Two-Stage Regulator Introduction The Type R632A is an Underwriters Laboratories (UL®) listed regulator designed for Two-Stage LP-Gas systems. The unit is designed to reduce the tank pressure through an integral two-stage system to 11 inches w.c. / 27.4 mbar. The first-stage screened drip-lip vent is oriented downward and the second-stage vent is oriented over the outlet as standard. Features • 20-Year Recommended Replacement Life – The Type R632A is designed using rugged time proven design concepts with enhancements to the corrosion resistance and durability of materials, both internally and externally. With proper installation and periodic inspection and maintenance the Type R632A design has a 20-Year Recommended Replacement Life. In some environmental conditions earlier replacement may be required. • Improved Regulations – Fisher®’s large molded fabric reinforced diaphragm and spring assisted vent stabilizer deliver accurate, stable regulation. • Superior Overpressure Protection – The combination of a high capacity relief valve and large vent provide overpressure protection which exceeds UL standards. Figure 1. Type R632A Integral Two-Stage Regulator • Easy System Checks – Intermediate and outlet 1/8-inch NPT inlet and outlet gauge taps orifice to a number 54 drill size for easy gas system checks. • Corrosion-Resistant – Added corrosion resistance with an internal and external coating process for all castings prior to painting, stainless steel relief valve spring and retainer and a non-corrosive relief valve seat. • Positive Drainage – When installed properly with the spring case pointed down the Fisher Positive Drainage design allows any moisture formed in the spring case to drain out eliminating the problems with corrosion and freezing of the water in the spring case. Table 1. Selected Capacities for Type R632A Integral Two-Stage Regulators OUTLET PRESSURE SETTING, SPRING RANGE INLET PRESSURE CAPACITIES IN THOUSANDS BTU/HR PROPANE(1) 11 inches w.c. / 27.4 mbar setting, 9 to 13 inches w.c. / 22.4 to 32.4 mbar spring range 1. Capacities are based on 2 inches w.c. / 5.0 mbar droo

Open the catalog to page 1
Type R632A Integral Two-Stage Regulator - 2

1/8-27 NPT INTERMEDIATE / OUTLET GAUGE TAPS 1/4 INCH INVERTED FLARE 3.63 / 92 TAPPED FOR 1/4-20 MOUNTING SCREWS Figure 2. Type R632A Dimensions Table 2. Ordering Information TYPE NUMBER OUTLET ADJUSTMENT SETTING OUTLET PRESSURE RANGE 1/4 inch x 1/2 inch FNPT 850,000 FPOL x 1/2 inch FNPT CONNECTIONS INLET X OUTLET 1/4 inch x 3/4 inch FNPT FPOL x 3/4 inch FNPT 1. Capacities are based on 30 psig / 2.07 bar inlet pressure and 2 inches w.c. / 5.0 mbar droop. 2. First and second stage spring case vents opposite gauge taps. LP-Gas Equipment Emerson Process Management Regulator Technologies, Inc....

Open the catalog to page 2

All FISHER REGULATORS catalogs and technical brochures

  1. R Series

    2 Pages

  2. LP-31

    96 Pages

  3. 1301F, 1301G

    12 Pages

  4. 630 Regulator

    16 Pages

  5. S200 series

    32 Pages

  6. R622 series

    8 Pages

  7. cs200 series

    40 Pages

  8. CS400 Series

    60 Pages

Archived catalogs