Introduction
The Type LR125 is a pilot-operated, pressure-reducing regulator designed for liquid industrial and commercial applications. It is suitable for water and oil applications and offers features such as smooth operation, tight shutoff, and long life. The regulator is available in full stainless steel construction for harsh environments.
Features and Benefits
  • Tight Shutoff: Utilizes a diaphragm and metal plug to resist particle erosion.
  • Debris Protection: Engineered flow path and internal inlet strainer prevent large particles from entering the regulator.
  • High Accuracy: Offers multiple control pressure ranges for precise control.
  • Long Life: Robust design with a fully supported diaphragm to prevent damage.
  • Full Usable Capacity: Laboratory tested for confidence in published flow capacity.
  • Easy In-Line Maintenance: Top-entry design allows for quick inspection and replacement of parts.
  • Versatility: Compatible with standard construction materials and end connections.
Specifications
The document details various body sizes, end connection styles, and structural design ratings. It includes maximum inlet and outlet pressures, temperature capabilities, and regulating capacities. Construction materials include options for steel and stainless steel components.
Principle of Operation
The regulator maintains outlet pressure above the set point, keeping the pilot valve plug closed. When outlet pressure decreases, the pilot plug opens, reducing loading pressure and allowing the main valve to open. As outlet pressure rises, the pilot valve closes, building up loading pressure for tight shutoff.
Tables and Figures
  • Table 1: Main valve body sizes, materials, and maximum operating pressures.
  • Table 2: Pilot maximum cold working pressures.
  • Table 3: Outlet pressure ranges for different pilot types.
  • Table 4: Diaphragm material selection based on temperature and application.
  • Figure 3: Operational schematic illustrating pressure dynamics within the regulator.
Capacity and Pressure Data
Tables provide data on the regulator's capacity in gallons per minute (GPM) and liters per minute (L/min) for different body sizes at various droop percentages and pressure settings. The tables note that the recommended maximum pressure drop ratio of 0.65 is exceeded in some cases.
Dimensions
Figure 5 and Table 13 detail the dimensions of the Type LR125 with the Type MR95H/MR95HP Pilot, including measurements for different body sizes and materials.
Ordering Information
The document provides an ordering guide specifying options for body size, material, end connection style, diaphragm material, O-ring material, travel indicator, and inlet body tap. It also includes options for pilot diaphragm material, valve plug material, and outlet pressure range. Replacement parts kits are available as optional items.
Contact Information
Contact details for Emerson Automation Solutions are provided for various regions, including the Americas, Europe, Asia Pacific, and the Middle East and Africa.
Disclaimer
The document includes a disclaimer stating that the information is for informational purposes only and does not constitute warranties or guarantees. Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use, or maintenance of any product.
See more

Catalog excerpts

Type LR125 Pressure Reducing Liquid Regulator-1

Type LR125 Pressure Reducing Liquid Regulator • Rugged design • Reliable • Thoroughly tested • Internally actuated • Compact • , 2, 3, 4 in. body sizes 1 • ecommended for water R and oil applications • ull SST construction F available for harsh environments • API 614 Compliant Figure 1. Type LR125 Pressure Reducing Liquid Regulator Introduction The Type LR125 pilot-operated, pressure reducing regulator is designed for liquid industrial/commercial applications. The Type LR125 provides smooth operation, tight shutoff and long life. Its internally actuated metal plug eliminates disadvantages associated with flexible element style regulators, and the specially engineered flow path deflects debris, protecting the seat from damage and erosion. The Type LR125 is used in conjunction with a Type MR95H/MR95HP pilot and Type 112 restrictor. An internal inlet strainer prevents large particles from entering the main valve, limiting damage to internal parts. Tight Shutoff—The Type LR125 uses a diaphragm and metal plug, eliminating the disadvantages of flexible element style regulators. When open, the metal plug deflects particles and debris away from the diaphragm. The result is enhanced resistance to particle erosion, which provides excellent shutoff over an extended life. When closed, loading pressure and the main spring push the diaphragm onto the taperededged

 Open the catalog to page 1
Type LR125 Pressure Reducing Liquid Regulator-2

Type LR125 Specifications The Specifications section lists the specifications for the Type LR125 regulator. Factory specification is stamped on the nameplate fastened on the regulator at the factory. Options •  Pre-piped Pilot Supply •  Travel Indicator Construction Materials Type LR125 Main Valve Body: WCC Steel, CF8M or CF3M Stainless Steel Bonnet: Steel or Stainless Steel Bonnet Bushing: Steel or Stainless Steel Cage: Stainless steel Spring: Stainless steel Top Plug: Stainless steel Bottom Plug: Stainless steel Internal Inlet Strainer: Stainless steel Diaphragm: Nitrile (NBR) or Fluorocarbon...

 Open the catalog to page 2
Type LR125 Pressure Reducing Liquid Regulator-3

TRIM PACKAGE TYPE LR125 PRESSURE REDUCING REGULATOR Figure 2. Type LR125 Features and Benefits style regulators. To prevent damage, the diaphragm is fully supported in both the open and closed positions. These features enable the Type LR125 components to work longer with less wear and tear. 5 Full Usable Capacity—Fisher™ branded regulators are laboratory tested. One hundred percent of the published flow capacity can be used with confidence. Thorough Laboratory Testing—Emerson Process Management Regulator Technologies, Inc. (Emerson) state-of-the-art flow laboratory allows thorough testing of...

 Open the catalog to page 3
Type LR125 Pressure Reducing Liquid Regulator-4

TYPE MR95H/MR95HP PILOT TYPE MR95H/MR95HP PILOT TYPE 112 RESTRICTOR TYPE 112 RESTRICTOR CONTROL SPRING CONTROL SPRING DIAPHRAGM DIAPHRAGM SUPPLY LINE SUPPLY LINE VALVE PLUG VALVE PLUG MAIN SPRING MAIN SPRING DIAPHRAGMAND DIAPHRAGM AND PLUG ASSEMBLY PLUG ASSEMBLY INLET PRESSURE INTERNAL STRAINER INTERNAL STRAINER OUTLET PRESSURE ATMOSPHERIC PRESSURE LOADING PRESSURE TYPE LR125 WITH TYPE MR95H/MR95HP PILOT AND TYPE 112 RESTRICTOR Figure 3. Type LR125 Operational Schematic 11 Easy-to-Maintain—The pilot is designed to allow quick and simple in-line trim inspection and parts replacement. Powder Paint...

 Open the catalog to page 4
Type LR125 Pressure Reducing Liquid Regulator-5

Type LR125 Table 1. Type LR125 Main Valve Body Sizes, End Connection Styles, Structural Design Ratings and Maximum Operating Inlet Pressures(1) MAIN VALVE BODY SIZE In. MAIN VALVE BODY MATERIAL MAXIMUM OPERATING INLET PRESSURE(3) psig bar psig NPT or SWE (1 and 2 in. only) 1500 103 600 CL150 RF 290 20.0 290 WCC Steel CL300 RF 750 51.7 CL600 RF 1500 103 600 PN 16/25/40 RF(4) 580 40.0 1, 2, 3 and 4 25, 50, 80 and 100 NPT (1 and 2 in. only) 1440 99.2 550 CL150 RF 275 19.0 275 CF8M Stainless steel CL300 RF 720 49.6 CL600 RF 1440 99.2 550 PN 16/25/40 RF(4) 580 40.0 1. The pressure/temperature limits...

 Open the catalog to page 5
Type LR125 Pressure Reducing Liquid Regulator-6

OUTLET PRESSURE (P2) OUTLET PRESSURE (P2) psig / bar psig / bar INLET PRESSURE (P1) INLET PRESSURE (P1) psig / bar psig / bar SIZABLE REGION INCIPIENT CAVITATION REGION FULL CAVITATION REGION Figure 4. Cavitation Sizing for Water Table 6. Main Valve Minimum Differential Pressures(1) MAIN VALVE BODY SIZE In. 19B0781X022, Light Blue and White MINIMUM DIFFERENTIAL, PERCENT OF CAPACITY DIAPHRAGM MATERIAL MAIN SPRING PART NUMBER AND COLOR 1. See Table 1 for structural design ratings and Table 2 for pilot rating. Table 7. Flow and Sizing Coefficients for Type LR125 Main Valve at 100% Capacity MAIN...

 Open the catalog to page 6
Type LR125 Pressure Reducing Liquid Regulator-7

Type LR125 Table 9. Type 112 Restrictor Flow Coefficients RESTRICTOR SETTING Table 10. Approximate Weights Including Type MR95H/MR95HP Pilot and Restrictor MAIN VALVE BODY, LBS / kg Installation The robust design of the Type LR125 allows this regulator to be installed indoors or outdoors. This regulator is designed to withstand the elements. The powder paint coating protects regulator against minor impacts, abrasions and corrosion. When installed outdoors, the Type LR125 does not require protective housing. However, the Type MR95H/MR95HP pilot should be oriented so that the pilot spring case...

 Open the catalog to page 7
Type LR125 Pressure Reducing Liquid Regulator-8

Type LR125 Table 11. Cv(1) at % Droop (Pressure Offset Below Setpoint)(2) SPRING RANGE AND COLOR 80 to 400 psig / 5.5 to 27.6 bar Silver Spring     – Exceeds recommended maximum pressure drop ratio of 0.65. 1. Type LR125 on liquid service with 1/2 NPT Type MR95H/MR95HP Pilot, 100% Cage Capacity with internal inlet strainer and Type 112 Restrictor Setting of “4”. 2. Values published in this table are laboratory tested and are presented based on % droop (negative control deviation only) or pressure offset below setpoint.

 Open the catalog to page 8
Type LR125 Pressure Reducing Liquid Regulator-9

Type LR125 Table 12. Capacity(1), Water (GPM / L/min) for 1 and 2 in. / DN 25 and 50 Bodies at % Droop (Pressure Offset Below Setpoint)(2) SPRING RANGE AND COLOR OUTLET PRESSURE psig

 Open the catalog to page 9
Type LR125 Pressure Reducing Liquid Regulator-10

Type LR125 Table 12. apacity(1), Water (GPM / L/min) for 3 and 4 in. / DN 80 and 100 Bodies at % Droop (Pressure Offset Below C Setpoint)(2) (continued) SPRING RANGE AND COLOR OUTLET PRESSURE psig 15

 Open the catalog to page 10

All FISHER REGULATORS catalogs and technical brochures

  1. R Series

    2  Pages

  2. LP-31

    96  Pages

  3. CS 200 series

    2  Pages

  4. 1301F, 1301G

    12  Pages

  5. MR95 and MR98

    2  Pages

  6. 630 Regulator

    16  Pages

  7. S200 series

    32  Pages

  8. R622 series

    8  Pages

  9. cs200 series

    40  Pages

  10. CS400 Series

    60  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.