Types MR105 and MR108 High capacity industrial regulators. TYPE MR108 LOW-PRESSURE ACTUATOR NEW TYPE MR105 HIGH-PRESSURE ACTUATOR Types MR105 and MR108 Types MR105 and MR108 regulators provide fast, accurate, and reliable pressure control for a variety of liquid and gas applications. A simple and durable design is utilized to withstand dirt and debris common in many liquid applications without sticking and without compromising shut-off performance. Applications include boiler feed water, cooling water, lubrication oil, and any critical service where the fluid is not free of impurities. Product advantages: • Available constructions to meet NACE MR0175-2003 and NACE MR0103 requirements for Sour Gas Service Capability • ANSI/FCI 70-3-2004 Class VI Shutoff • Large Flow • Travel indicator for Type MR105 • Fast Response • Multiple end connection options • Suitable for High-Temperature Applications up to 250°F / 121°C Features: Actuator Type and Maximum Outlet and Emergency Casing Pressures: Low-Pressure Actuator: 70 psig / 4,8 bar High-Pressure Actuator: 400 psig / 27,6 bar(1) Outlet Pressure Ranges: 5 to 300 psig / 0,35 to 20,7 bar(2) Temperature Capabilities: Nitrile (NBR): -20° to 180°F / -29° to 82°C Fluorocarbon (FKM): 20° to 250°F / -7° to 121°C Downstream Control Line Connection Size: 1/2 NPT Maximum Pressure Over Setpoint to Avoid Internal Parts Damage: Low-Pressure Actuator: 20 psig / 1,4 bar High-Pressure Actuator: 120 psig / 8,3 bar 1. For constructions with Fluorocarbon (FKM) diaphragm, maximum outlet and emergency casing pressures are limited to 230 psig / 15,8 bar or the body rating limit, whichever is lower. 2. For high-pressure actuator constructions with Fluorocarbon (FKM) diaphragm, maximum set pressure is limited to 150 psig / 10,3 bar.
Open the catalog to page 1The One Stop For Your Complete Industrial Regulating Solutions. Fisher® pressure reducing and backpressure regulators area available in a wide range of sizes and contructions to satisfy your application requirements. 1. For high-pressure actuator constructions with Fluorocarbon (FKM) diaphragm, maximum outlet and emergency casing pressures are limited to 230 psig / 15,8 bar or the body rating limit, whichever is lower. 2. For high-pressure actuator constructions with Fluorocarbon (FKM) diaphragm, maximum set pressure is limited to 150 psig / 10,3 bar. Emerson Process Management Regulator Technologies,...
Open the catalog to page 216 Pages
16 Pages
2 Pages
118 Pages
2 Pages
16 Pages
8 Pages
16 Pages
16 Pages
24 Pages
12 Pages
20 Pages
4 Pages
4 Pages
1 Page
11 Pages
12 Pages
5 Pages
4 Pages
28 Pages
5 Pages
2 Pages
96 Pages
2 Pages
24 Pages
12 Pages
2 Pages
12 Pages
40 Pages
24 Pages
36 Pages
28 Pages
28 Pages
20 Pages
36 Pages
16 Pages
12 Pages
16 Pages
16 Pages
32 Pages
8 Pages
20 Pages
40 Pages
60 Pages
8 Pages
1 Page
1 Page