cad

.Fisher.comFisher™ D4 Control Valve Assembly
16Pages

{{requestButtons}}

Catalog excerpts

.Fisher.comFisher™ D4 Control Valve Assembly - 1

Product Bulletin Fisher™ D4 Control Valve Assembly The Fisher D4 control valve is a compact, rugged globe valve designed primarily for high-pressure throttling applications using either pneumatic or electric control. This valve is ideal for use on pressure and flow control applications within the oil and gas production industry. The D4 is an excellent control valve for high-pressure separators, scrubbers, and other processing equipment. These valves are especially useful for either throttling or on/off control of liquids or gases which are gritty, sticky, or which have a tendency to build up on internal valve parts. If the control valve requires maintenance, the trim and packing can be maintained by removing the deep-bore hammer nut and lifting the actuator/bonnet assembly off the valve without disassembling the actuator. W9933-5 FISHER D4 CONTROL VALVE WITH Gen 2 easy-Drive™ ELECTRIC ACTUATOR (NPS 2 RF FLANGED END CONNECTION) Features Electric and Pneumatic n Safer Bonnet / Valve Body Connection— Unique design provides additional protection if disassembly of bonnet/valve body connection is inadvertently started while there is still pressure in the valve body. Pins mounted in the valve bonnet help ensure the bonnet disengages from the valve body as the hammer nut is removed, while the threads are still engaged. n Heavy-Duty Guiding—Massive guiding (figures 3 and 4) positively aligns the valve plug in the seat ring for reliable service. The screwed-in seat ring completely encloses the seat ring gasket. n Quad-O compliant Packing System --Features Fisher ENVIRO-SEAL™ packing technology to provide reduced packing maintenance and meet Low E fugitive emission requirements for Leak Detection and Repair (LDAR) programs in compliance with the Code of Federal Regulations (CFR) 40, Part 60, Subpart OOOO. FISHER D4 CONTROL VALVE (NPS 2 NPT END CONNECTION) n NACE Constructions—NACE compatible trim is available with the D4 control valve. These constructions meet the metallurgical requirements of NACE MR

Open the catalog to page 1
.Fisher.comFisher™ D4 Control Valve Assembly - 2

Product Bulletin Features (continued) Electric n Low Power Consumption-- The Fisher easy-Drive Electric and Pneumatic n Quick-Change Valve Plug—Removable groove pin allows quick, easy valve plug replacement. n Severe Service Capability with Tungsten Carbide Trim—D4 valves are available with tungsten carbide trim for erosive service. This trim is designed specifically for severe service applications in the oil and gas industry. Durable tungsten carbide trim may benefit your application by wearing better and lasting longer. n Easy Installation—Compact design allows installation where space is...

Open the catalog to page 2
.Fisher.comFisher™ D4 Control Valve Assembly - 3

Product Bulletin D103039X012 Valve Specifications Available Actuation Configurations Spring-To-Close Pneumatic Spring-To-Open Pneumatic Electric Valve Sizes and End Connection Styles(1) See table 3 Dimensions See tables 12 and 13 and figures 3 and 4. Face-to-face dimensions for flanged valves conform to ISA-75.03 (CL150-600) and ANSI/ISA-75.16 Short (CL900/1500) Maximum Inlet Pressures and Temperatures(1) Flanged connections are consistent with the ASME B16.34 pressure-temperature class, subject to Material Temperature Capabilities for the Valve Body Assembly (see following specification)....

Open the catalog to page 3
.Fisher.comFisher™ D4 Control Valve Assembly - 4

Product Bulletin Actuator Specifications ELECTRIC ACTUATOR Material Temperature Capabilities(1) Electric Actuator Assembly: -20 to 70°C (-4 to 158°F) ambient Available Electric Actuator Configurations Gen 2 easy-Drive Electric On/Off (snap acting) Gen 2 easy-Drive Electric Positioning (flow or pressure control) Maximum Current Draw 4 amps Idle Current Draw 15 mA at 24VDC, 25 mA at 12VDC 30 mA at 24VDC, 50 mA at 12VDC with RPU-100 Nominal Stroke Speed(2) 3.9 mms (0.15 inch/s) at 24VDC 2.2 mm/s (0.09 inch/s) at 12VDC(3) Control Signals On/Off: Dry contact, Modbus RTU Positioning: 4-20 mA,...

Open the catalog to page 4
.Fisher.comFisher™ D4 Control Valve Assembly - 5

Product Bulletin Table 1. Hazardous Area Classifications - CSA (Canada and United States) CERTIFICATION BODY CERTIFICATION OBTAINED ENTITY RATING TEMPERATURE CODE ENCLOSURE RATING Table 2. EMC Summary Results - Immunity PORT BASIC STANDARD TEST LEVEL Rated power frequency magnetic field 1kV cable shield, and line to ground Performance criteria is +/- 5% stem position 1. A= No degradation during testing. B = Temporary degradation during testing, but is self recovering. Ordering Information When ordering, specify: 3. Range of flowing inlet pressures 4. Pressure drops a. Range of flowing...

Open the catalog to page 5
.Fisher.comFisher™ D4 Control Valve Assembly - 6

Product Bulletin Table 3. Valve Sizes and Connection Styles VALVE SIZE, NPS PORT DIAMETER, (INCHES) RING TYPE JOINT (RTJ) FLANGED CL900 and CL600 1500 RAISED FACE (RF) FLANGED Table 4. Fisher D4 Control Valves Approximate Weights, Kg (Pounds)(1) PNEUMATIC VALVE SIZE AND CLASS Table 5. Typical Combinations of Metal Trim Parts DESIGNATION VALVE PLUG Tungsten Carbide Tungsten carbide / S17400 (NACE MR0175/ISO 15156) Tungsten carbide / S17400 (NACE MR0175/ISO 15156) Table 6. Fisher D4 Environmental Limits for NACE MR0175/ISO 15156 with Sour Trim MAXIMUM TEMPERATURE MAXIMUM H2S PARTIAL PRESSURE...

Open the catalog to page 6
.Fisher.comFisher™ D4 Control Valve Assembly - 7

Product Bulletin Table 8. Maximum Shutoff Pressure Drops(1) for Fisher D4 Control Valves with Pneumatic Actuator (Spring-to-Close) When Used with Instrumentation with Restricted Output Range(2) INPUT SIGNAL TO ACTUATOR Heavy Rate Heavy Rate INITIAL SPRING SETTING PORT DIAMETER Maximum Pressure Drop 1. The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be exceeded. 2. For example, an Electro-Pneumatic Transducer calibrated for 0.4-2.0 bar (6-30 psig) output pressure. 3. For applications with downstream pressure in excess of 118 bar...

Open the catalog to page 7
.Fisher.comFisher™ D4 Control Valve Assembly - 8

Product Bulletin Table 11. Fisher D4 easy-Drive Maximum Pressure Drop MAXIMUM PRESSURE DROP(1) 1. Downstream pressure, P2, is limited to 2250 psig. Figure 2. Fisher easy-Drive Actuator with RPU-100 Designed for use in Fisher easy-Drive actuators, the RPU-100 provides energy for positioning the actuator to the user-defined location on loss of incoming power. Figure 1. Fisher RPU-100 with Wiring Harness

Open the catalog to page 8