1. Catalogs
  2. FISHER REGULATORS
  3. Fisher™ D4 Control Valve Assembly

Fisher™ D4 Control Valve Assembly

Fisher™ D4 Control Valve Assembly
1 / 16 PagesView full catalog

Fisher™ D4 Control Valve Assembly

Product catalog summary
Overview: The Fisher D4 Control Valve is a compact and robust globe valve designed for high-pressure throttling applications, particularly in the oil and gas industry. It is suitable for both pneumatic and electric control, primarily used for pressure and flow control in high-pressure separators and scrubbers.
Key Features:
  • Safety: Features a unique bonnet/valve body connection for enhanced safety during disassembly under pressure.
  • Guiding and Maintenance: Heavy-duty guiding ensures reliable service, with easy maintenance without removing the valve body from the piping system.
  • Compliance: Includes a Quad-O compliant packing system to meet low emission requirements.
  • Material Options: Offers NACE compatible trim, meeting specific metallurgical standards.
  • Installation and Flexibility: Compact design allows for easy installation in limited spaces, with various port diameters and trim materials available.
Specifications:
  • Actuation Configurations: Available in spring-to-close and spring-to-open pneumatic, and electric configurations.
  • Valve Sizes and Connections: Various sizes and connection styles conforming to industry standards.
  • Pressure and Temperature Limits: Rated for high pressures and temperatures, with specific limits detailed in tables.
  • Construction Materials: Valve body and bonnet made from ASME SA 352 LCC, with other components from materials like S20910 and S31600.
Actuator Specifications:
  • Electric Actuator: Operates with low power consumption, suitable for low temperatures, supports remote monitoring and configuration.
  • Pneumatic Actuator: Suitable for low-temperature applications, with configurations for spring-to-open and spring-to-close operations.
Installation and Ordering: The valve can be installed in any position, typically with the actuator above the valve. Ordering requires specifying application details, controlled fluid characteristics, and control valve assembly information.
Pressure Drop Table: Provides maximum pressure drop values for various port diameters, with a maximum of 293 bar (4250 psi) for smaller diameters.
Actuator Details: The RPU-100 is designed for use with Fisher easy-Drive actuators, providing energy for positioning during power loss. Dimensions for pneumatic and electric actuators are detailed in tables, with figures illustrating configurations.
Dimensions: Includes detailed dimensions for different valve body configurations and actuator types, with measurements in both metric and imperial units.
Figures: Illustrate the RPU-100, easy-Drive actuator, and various valve configurations, providing visual guidance on installation and setup.
Disclaimer: Information is for informational purposes only and does not constitute a warranty. Product designs and specifications may change without notice.
See more

Catalog excerpts

Fisher™ D4 Control Valve Assembly-1

Product Bulletin Fisher™ D4 Control Valve Assembly The Fisher D4 control valve is a compact, rugged globe valve designed primarily for high-pressure throttling applications using either pneumatic or electric control. This valve is ideal for use on pressure and flow control applications within the oil and gas production industry. The D4 is an excellent control valve for high-pressure separators, scrubbers, and other processing equipment. These valves are especially useful for either throttling or on/off control of liquids or gases which are gritty, sticky, or which have a tendency to build up on internal valve parts. If the control valve requires maintenance, the trim and packing can be maintained by removing the deep-bore hammer nut and lifting the actuator/bonnet assembly off the valve without disassembling the actuator. W9933-5 FISHER D4 CONTROL VALVE WITH Gen 2 easy-Drive™ ELECTRIC ACTUATOR (NPS 2 RF FLANGED END CONNECTION) Features Electric and Pneumatic n Safer Bonnet / Valve Body Connection— Unique design provides additional protection if disassembly of bonnet/valve body connection is inadvertently started while there is still pressure in the valve body. Pins mounted in the valve bonnet help ensure the bonnet disengages from the valve body as the hammer nut is removed, while the threads are still engaged. Heavy-Duty Guiding—Massive guiding (figures 3 and 4) positively aligns the valve plug in the seat ring for reliable service. The screwed-in seat ring completely encloses the seat ring gasket. Quad-O compliant Packing System --Features Fisher ENVIRO-SEAL™ packing technology to provide reduced packing maintenance and meet Low E fugitive emission requirements for Leak Detection and Repair (LDAR) programs in compliance with the Code of Federal Regulations (CFR) 40, Part 60, Subpart OOOO. FISHER D4 CONTROL VALVE (NPS 2 NPT END CONNECTION) NACE Constructions—NACE compatible trim is available with the D4 control valve. These constructions meet the metallurgical requirements of NACE MR0175 / I

 Open the catalog to page 1
Fisher™ D4 Control Valve Assembly-2

Product Bulletin ■ Quick-Change Valve Plug—Removable groove pin allows quick, easy valve plug replacement. ■ Severe Service Capability with Tungsten Carbide Trim—D4 valves are available with tungsten carbide trim for erosive service. This trim is designed specifically for severe service applications in the oil and gas industry. Durable tungsten carbide trim may benefit your application by wearing better and lasting longer. ■ Easy Installation—Compact design allows installation where space is a premium. Screwed valve bodies feature compact face-to-face dimensions while flanged valve bodies conform...

 Open the catalog to page 2
Fisher™ D4 Control Valve Assembly-3

Product Bulletin D103039X012 Valve Specifications Available Actuation Configurations Spring-To-Close Pneumatic Spring-To-Open Pneumatic Electric Valve Sizes and End Connection Styles(1) See table 3 Dimensions See tables 12 and 13 and figures 3 and 4. Face-to-face dimensions for flanged valves conform to ISA-75.03 (CL150-600) and ANSI/ISA-75.16 Short (CL900/1500) Maximum Inlet Pressures and Temperatures(1) Flanged connections are consistent with the ASME B16.34 pressure-temperature class, subject to Material Temperature Capabilities for the Valve Body Assembly (see following specification). For...

 Open the catalog to page 3
Fisher™ D4 Control Valve Assembly-4

Product Bulletin Actuator Specifications ELECTRIC ACTUATOR Material Temperature Capabilities(1) Electric Actuator Assembly: -20 to 70°C (-4 to 158°F) ambient Available Electric Actuator Configurations Gen 2 easy-Drive Electric On/Off (snap acting) Gen 2 easy-Drive Electric Positioning (flow or pressure control) Maximum Current Draw 4 amps Idle Current Draw 15 mA at 24 VDC, 25 mA at 12 VDC 30 mA at 24 VDC, 50 mA at 12 VDC with RPU-100 Nominal Stroke Speed(2) 3.9 mm/s (0.15 inch/s) at 24 VDC 2.2 mm/s (0.09 inch/s) at 12 VDC(3) Control Signals On/Off: Dry contact, Modbus RTU Positioning: 4-20 mA,...

 Open the catalog to page 4
Fisher™ D4 Control Valve Assembly-5

Product Bulletin Table 1. Hazardous Area Classifications - CSA (Canada and United States) Performance criteria is +/- 5% stem position 1. A= No degradation during testing. B = Temporary degradation during testing, but is self recovering. Ordering Information When ordering, specify: b. Reducing or relief (back pressure) a. Type (include chemical analysis, if available) b. Temperature (normal and maximum anticipated) 3. Range of flowing inlet pressures a. Range of flowing pressure drops b. Maximum drop at shutoff a. Minimum controlled flow 6. Input signal range to actuator Refer to the Specifications...

 Open the catalog to page 5
Fisher™ D4 Control Valve Assembly-6

Product Bulletin51.2:D4 April 2023 Table 3. Valve Sizes and Connection Styles

 Open the catalog to page 6
Fisher™ D4 Control Valve Assembly-7

Product Bulletin51.2:D4 April 2023 Table 8. Maximum Shutoff Pressure Drops(1) for Fisher D4 Control Valves with Pneumatic Actuator (Spring-to-Close) When Used with Instrumentation with Restricted Output Range(2)

 Open the catalog to page 7
Fisher™ D4 Control Valve Assembly-8

Product Bulletin Table 11. Fisher D4 easy-Drive Maximum Pressure Drop MAXIMUM PRESSURE DROP(1) 1. Downstream pressure, P2, is limited to 2250 psig. Figure 2. Fisher easy-Drive Actuator with RPU-100 Designed for use in Fisher easy-Drive actuators, the RPU-100 provides energy for positioning the actuator to the user-defined location on loss of incoming power. Figure 1. Fisher RPU-100 with Wiring Harness

 Open the catalog to page 8
Fisher™ D4 Control Valve Assembly-9

Product Bulletin51.2:D4 April 2023 Table 12. Dimensions - Pneumatic Actuator(1)

 Open the catalog to page 9
Fisher™ D4 Control Valve Assembly-10

Product Bulletin Figure 3. Fisher D4 Valve Dimensions, Spring-To-Close (also see tables 12 and 13)

 Open the catalog to page 10
Fisher™ D4 Control Valve Assembly-11

Product Bulletin Figure 4. Fisher D4 Valve Dimensions, Spring-To-Open (also see tables 12 and 13)

 Open the catalog to page 11
Fisher™ D4 Control Valve Assembly-12

Product Bulletin Figure 5. Fisher D4 Control Valve with easy-Drive Electric Actuator and NPS 2 Flanged Valve Body D

 Open the catalog to page 12
Fisher™ D4 Control Valve Assembly-13

Product Bulletin 51.2:D4 April 2023

 Open the catalog to page 13
Fisher™ D4 Control Valve Assembly-15

Product Bulletin 51.2:D4 April 2023

 Open the catalog to page 15
Fisher™ D4 Control Valve Assembly-16

Product Bulletin 51.2:D4 April 2023 Neither Emerson nor any of its affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher, easy-Drive, and ENVIRO-SEAL are marks owned by one of the companies in the Emerson business unit of Emerson Electric Co. Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented...

 Open the catalog to page 16

Archived catalogs

  1. CS400 Series

    60  Pages

  2. cs200 series

    40  Pages

  3. R622 series

    8  Pages

  4. S200 series

    32  Pages

  5. 630 Regulator

    16  Pages

  6. MR95 and MR98

    2  Pages

  7. 1301F, 1301G

    12  Pages

  8. CS 200 series

    2  Pages

  9. LP-31

    96  Pages

  10. R Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.