1305 Series Regulators
4Pages

{{requestButtons}}

Catalog excerpts

1305 Series Regulators - 1

1305 Series Regulators Introduction The 1305 Series regulators (Figure 1) are directoperated, pressure-reducing regulators that resist hydrate formation and regulator freeze-up. The regulators are suitable for service with natural gas, air, propane, and other gases compatible with the internal parts. 1305 Series regulators are typically used on high-pressure lines from wellheads and separators. Regulator freeze-up resistance (see Figure 2) occurs as the pipeline gas warms the finned inlet adaptor and the orifice area. As the gas cools within the inlet adaptor due to pressure drop and volume expansion, the warm inlet adaptor helps keep the gas temperature above the freezing point of water and the hydrate formation temperature. Figure 1. 1305 Series Regulator with Tapped Lower Casing Connection gas chilled by pressure reduction here union nut Features   •  Durable—Brass inlet adaptor and spring case plus stainless steel trim parts make 1305 Series regulators rugged and corrosion-resistant.   •  Easy Maintenance—Removing the regulator union nut (see Figure 2) allows valve disk maintenance while inlet adaptor remains in pipeline.   •  High Pressure Capabilities—With brass and stainless steel construction, 1305 Series regulators handle up to 4000 psig (276 bar) inlet pressure at 100°F (38°C).   •  Resists Hydrate Formation and Regulator Freeze-up—Design of finned inlet adaptor allows warming of reduced pressure gas.   •  Sour Gas Service Capabilities—Optional materials are available for applications handling sour gases. These constructions comply with the recommendations of NACE International Standards MR0175 and MR0103. Overpressure Protection Like most regulators, the 1305 Series have outlet pressure ratings lower than their inlet pressure ratings. finned inlet adapter heated by main flow stream to help prevent regulator freeze-up w060-1* INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE Figure 2. Type 1305C Operational Schematic Complete downstream overpressure protection is needed if the actual inlet pressure exceeds the outlet pressure rating. Overpressuring any portion of a regulator or associated equipment may cause leakage, part damage, or personal injury due to bursting of pressure-containing parts or explosion of accumulated gas. Regulator operation within ratings does not preclude the possibility of damage from external sources or from debris in the pipeline. A regulator should be inspected for damage periodicall

Open the catalog to page 1
1305 Series Regulators - 2

1305 Series Specifications Available Configurations, Body Sizes and Connection Styles Type 1305C(1): 1/4 NPT outlet connection and 1 NPT inlet adaptor connection Type 1305D(2): 1/4 NPT outlet connection and 1 NPT inlet adaptor connection Maximum Allowable Inlet Pressure(3) 4000 psig (276 bar) Outlet Pressure Ranges Type 1305C With Spring 1D387227022 (Blue): 0 to 75 psig (0 to 5,2 bar) With Spring 1B788527022 (Silver): 0 to 150 psig (0 to 10,3 bar) With Spring 1D465127142 (Red): 0 to 225 psig (0 to 15,5 bar) Type 1305D: 200 to 500 psig (13,8 to 34,5 bar) Maximum Emergency Outlet (Casing)...

Open the catalog to page 2
1305 Series Regulators - 3

TYPE 1305C 5/64-inch 2,0 orifice ( mm) spring 1b788527022 setpoint inlet pressure: 1000 PSIG (69,0 bar) outlet pressure: 60 PSIG (4,1 bar) flow: 64.5 scfh (1,7 nm3/h) 5,0 outlet pressure - PSIG gas flow (scfh (Nm /h) of 0.6 specific gravity gas at 60°F (0°C) and 14.7 PSIA (1,01325 bar)) 3 note: inlet pressure indicated on each curve Figure 3. Typical 1305 Series Regulator Capacities =  Gas flow, SCFH(1) (60°F and 14.7 psia) =  Absolute inlet pressure, psia (add 14.7 psi   to gauge inlet pressure to obtain absolute   inlet pressure) =  Wide-open gas sizing coefficient from   Specifications...

Open the catalog to page 3
1305 Series Regulators - 4

NOTE: 1   this dimension is 4.94 INCHES (126 mm) on type 1305d regulators. all other dimensions for type 1305d regulators are the same as the dimensions shown for type 1305c regulators. Ordering Information   3. Flowing inlet pressures (maximum, minimum, nominal) When ordering, specify:   4. Desired outlet pressure setting or range   5. Range of flow rates (minimum controlled,   maximum, normal)   1. Composition and specific gravity of gas LinkedIn.com/company/emerson-automation-solutions Twitter.com/emr_automation Asia Pacific Singapore 128461, Singapore T  +65 6777 8211 Middle East and...

Open the catalog to page 4