DATA SHEET ARIAN Conventional Fire control panel The Arian range of conventional control panels features three models with 2, 4 and 8 Zones of detection. Housed in a stylish modern ABS housing, the Arian is the ideal control panel for smaller installations. Designed and manufactured to comply with the requirements of EN54 parts 2 and 4(1998) the Arian uses active End of Line monitoring to permit head removal protection as required by BS5839. (detector bases must be fitted with Diode) Programmable Zone coincidence and alarm delay timer (0-10 min) are standard features to help reduce false alarms. The one man test facility enables simple and rapid testing of the system at commissioning and during maintenance operations. Features: Two, four and eight zone non-expandable control panels. Up to 32 conventional smoke and/or heat detectors per zone. Active End of Line monitoring Programmable non-latching zones Delay timer programmable on/off per zone Zone coincidence programmable for adjacent zones. Two Access Levels One man test Supervised auxiliary 24 volt output 2 supervised/ monitored sounder circuits 2 programmable inputs for Class change, remote silence, remote reset etc. 2 Relay outputs fire and fault Power supply 1,5A at 28Vdc Fully EN54 part 2 and 4 compliant Future Features ORDERING INFO Repeater output Multiplexed output for Leds and additional relay outputs per zone Addressable Loop Interface card ARIAN 2 ARIAN 4 ARIAN 8 FIREGUARD SAFETY EQUIP CO.LTD,2ND FLOOR, 145-157 ST.JOHN STREET, LONDON EC1V 4PY UNITED KINGDOM Phone: +44 (0)8450 751042 Email: info@fireguard-uk.com Fax: +44 (0)8450 751043 Website: www.fireguard-uk.com

Open the catalog to page 1
Arian Range - 2

DATA SHEET ARIAN Conventional Fire control panel Technical Specifications Mains supply voltage Internal power supply Total output current Supply and battery charger monitored? Batteries monitored Max Battery size Mains Fuse Battery Fuse Max Current Draw from Battery (Mains Fail) 85-264V 50/60 Hz Min. 20 V DC – Max. 30 V DC (28.5 V DC nominal) Max. Ripple 1 V peak-peak 1,7A @230Vac YES YES 2 x 12V 7AH SLA 4 A – 250 V Slow Blow – 20 mm 1.6 Amp Resettable – Electronic Fuse 1.5 Amp Max.@ Max. Operating Temperature Detection Circuit Specification Number of circuits Max Cable resistance Max Cable...

Open the catalog to page 2

All Fireguard safety equip catalogs and technical brochures

  1. FIREMAN SUIT

    2 Pages

  2. SAFETY SHOES

    1 Pages

  3. Saxon range

    2 Pages

  4. Excel Series

    2 Pages