MS-25 - 1

MS-25(E) Rev 2 Addressable FACP With Built-in Communicator Addressable Fire Alarm Control Panels General The Fire•Lite MS-25(E) is a 25 point addressable Fire Alarm Control Panel (FACP) with built-in Digital Alarm Communicator Transmitter (DACT). This control panel supports up to 25 addressable devices in any combination of detectors and modules. With simple programming, operation on standard wire, and features such as drift compensation and maintenance alert, the MS-25(E) is a preferred alternative to conventional control panels in both new and retrofit applications. The JumpStart® (or auto-learn) feature and easy-to-set codewheel addressing of Honeywell Fire Systems (HFS) or equivalent Fire•Lite detectors and modules enable the system to be configured for fire protection without a programming utility. The default programming can be modified using the panels embedded web server. The integral DACT transmits system status (alarms, troubles, supervisories, etc.) to a remote monitoring location via the public switched telephone network. Reporting formats are contact ID, SIA 8 or SIA 20. NOTE: Unless otherwise specified, the term MS-25 is used in this data sheet to refer to the MS-25 and the MS-25E. For details on the Canadian version, see DF-60704. Features • SBUS supports two ANN-80 Remote Annunciators • JumpStart® auto-learn feature reduces installation time and makes programming easy. • Built-in digital communicator. • IP communicator compatible • Two programmable Style Y (Class B) notification appliance circuits (NACs). • Selectable strobe synchronization for System Sensor®, Gentex®, Wheelock® or AMSECO devices. • Two programmable Form-C relays and one Form-C trouble relay. • Automatic detector sensitivity testing (NFPA 72 compliant). • Point status eliminates calibrated smoke test requirements for NFPA 72. • Drift compensation. • Alarm verification per zone of detectors. • Walk-test. • Detectors and modules are code-wheel addressed for faster installation time. • Maintenance alert region. • Uses standard wire (unshielded or twisted pair). • Central Station reporting up to five zones. • Custom programming performed through the control panel’s built-in browser; no programming software is required. SLC Communication • Single addressable SLC loop which meets NFPA Style 4 (Class B) requirements. • 25 addressable device capacity (any combination of addressable detectors and modules). • Compatible with Honeywell Fire Systems (HFS) or equivalent Fire•Lite detectors and modules. Notification Appliance Circuits (NACS) • Two independently programmable output circuits. Circuits can be configured for the following outputs: – Style Y (Class B). – Door Holder Service (cannot be used for notification appliances). – Aux Power Source (cannot be used for notification appliances). • Silence Inhibit and Auto-silence timer options. • Continuous or Temporal code. • Selectable strobe synchronization per NAC. • Up to 2.0 A total output power, 1.0 A for auxiliary power and door holder. Each circuit can source up to the total system current 2.0 A.

Open the catalog to page 1
MS-25 - 2

Programming and Software • Auto-learn JumpStart® feature for easy programming reduces installation time. • Two programmable Form-C relay outputs. • 5 programming zones. • Custom programming can be performed through control panel’s built-in browser. User Interface LED INDICATORS • • • • • • AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Disabled (yellow) • Low Battery Fault (yellow) • Ground Fault (yellow) • Walk Test (yellow) KEYPAD CONTROLS • • • • • • • Acknowledge Silence Drill System Reset (lamp test) 10-key numeric keypad 5 Zones...

Open the catalog to page 2
MS-25 - 3

Product Line Information 005220: City Box Transmitter Module. MS-25: Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, transformer, backbox with door, manual, and required screws, cables, key, etc. Red, 120 VAC. 007860: DACT Phone Cord (2 required). MS-25E: Same as MS-25, but operates from 220/240 VAC. MS-25C: Same as MS-25, but listed for Canadian applications. For details on the Canadian version, see DF-60704. HONEYWELL FIRE SYSTEMS DEVICES HFS-P: Honeywell Fire Systems addressable photoelectric smoke detector. Includes base....

Open the catalog to page 3
MS-25 - 4

SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. Electrical Specifications • AC Power: MS-25: 120 VAC, 60 Hz,...