SXE-SSE DN 10÷50

SXE-SSE DN 10÷50
1 / 17 PagesView full catalog

SXE-SSE DN 10÷50

Product catalog summary
Technical Specifications
The document outlines the specifications for SXE and SSE Easyfit True Union ball and spring check valves, designed by Giugiaro Design. These valves are available in sizes DN 10 to 50, made from PVC-U material, and operate at a nominal pressure of PN 16 with water at 20°C. They have a temperature range of 0°C to 60°C and are compatible with various coupling standards, including solvent welding and threaded joints. The valves adhere to multiple international standards for construction, testing, and installation.
Design and Features
The Easyfit check valves feature an innovative installation method for reliable service and include a customizable Labelling System for easy identification. The SXE model uses a ball shutter, while the SSE model uses a spring-loaded shutter. Both models are suitable for vertical and horizontal installations, with the SXE model being preferable for vertical setups. The valves are designed for energy efficiency, reduced maintenance, and compatibility with various fluids, including aggressive acids.
Performance and Testing
The valves are tested according to ISO 9393 standards and comply with the European Directive 97/23/EC for pressurized equipment. A pressure variation graph shows the working pressure against temperature, indicating the valves' capability to handle a range of conditions. The Kv100 flow coefficient is provided for different valve sizes, showing the flow rate that results in a 1 bar pressure drop.
Installation and Maintenance
Installation criteria include recommendations for using the Easyfit multifunctional handle or Easytorque kit for union nut tightening. The valves require minimal maintenance under normal conditions, but procedures are outlined for dismounting and maintenance in case of leaks or wear.
Dimensions and Codes
Detailed dimensions and product codes are provided for various valve configurations, including options for solvent welding, threaded ends, and specific series like metric, BS, ASTM, and JIS.
Accessories and Customization
Accessories such as the Easyfit handle and Easytorque kit are available for installation and maintenance. The Labelling System allows for customization with company logos or service information, enhancing the identification and management of the valves in a system.
Installation Procedures
Detailed instructions are provided for installing SXE-SSE valves, which can be installed both vertically and horizontally. Key steps include ensuring pipe alignment to avoid mechanical stress, using the Easyfit multifunctional handle or Easytorque kit for tightening union nuts, and avoiding the use of mineral oils on rubber seals. It is recommended to support pipes with FIP pipe clips if necessary.
Valve Assembly
The assembly process involves reconstructing the valve using an exploded view, positioning the valve between end connectors, and ensuring the socket seal O-ring remains in place. The Easyfit handle or Easytorque wrench is used for tightening according to specified torque instructions.
Warnings
The document advises against using compressed air or gases for testing thermoplastic lines and recommends avoiding sudden valve closures to prevent accidental maneuvers.
Product Range
The PVC-U manual valves line includes various types of valves such as ball, butterfly, diaphragm, check, sediment strainers, air release, foot, and angle seat valves. These are suitable for conveying pressurized industrial fluids with maximum operating temperatures up to 60°C.
Contact Information
Contact details for FIP - Formatura Iniezione Polimeri are provided, including their location in Casella Genova, Italy, and contact numbers.
See more

Catalog excerpts

SXE-SSE DN 10÷50-1

UTILITIES & INDUSTRY Easyfit True Union ball and spring check valve

 Open the catalog to page 1
SXE-SSE DN 10÷50-2

SXE-SSE DN 10÷50 EASYFIT TRUE UNION BALL AND SPRING The Easyfit check CHECK VALVE valve line developed • Connection system for solvent weld and threaded joints with Giugiaro Design • Valve material compatibility (PVC-U) with water conveyance, drinking offers two different water and other food substances according to current regulations versions: SXE with ball • PN16 True Union valve body made for PVC-U injection moulding and compliant with European Directive 97/23/EC for PED pressurised equipshutter and SSE with ment. Test requirements compliant with ISO 9393 spring loaded shutter. • Short face...

 Open the catalog to page 2
SXE-SSE DN 10÷50-3

Customisable Labelling System: built-in LCE module on the valve body made up of transparent protection plug and customisable tag holder using the LSE set (available as accessory). The customisation potential lets you identify the valve on the system according to specific needs Optimised dynamic fluid design: energy savings thanks to the improved valve Kv value with consequent pressure drop reduction High surface finish ball shutter: wear reduction, increase in working life and reduced valve maintenance. Ideal for conveying dirty fluids, even with suspended solids and filaments thanks to the special...

 Open the catalog to page 3
SXE-SSE DN 10÷50-4

TECHNICAL DATA PRESSURE VARIATION ACCORDING TO TEMPERATURE For water and harmless uids to which the material is classied as CHEMICALLY RESISTANT. In other cases, a reduction of the nominal PN pressure is required (25 years with safety factor). Pressure drop PRESSURE DROP GRAPH KV100 FLOW COEFFICIENT The Kv100 ow coefficient is the Q ow rate of litres per minute of water at a temperature of 20°C that will generate p= 1 bar pressure drop at a certain valve position. The Kv100 values shown in the table are calculated with the SXE valve completely open.

 Open the catalog to page 4
SXE-SSE DN 10÷50-5

MINIMUM VALVE SEALING PRESSURE The PVC-U SXE valve can only be used with liquids with specic weight under 1.37g/cm3. The information in this leaet is provided in good faith. No liability will be accepted concerning technical data that is not directly covered by recognised international standards. FIP reserves the right to carry out any modication. Products must be installed and maintained by qualied personnel.

 Open the catalog to page 5
SXE-SSE DN 10÷50-6

Easyfit ball check valve with female ends for solvent welding, metric series EPDM Code EPDM Code Easyfit ball check valve with BSP threaded female ends Easyfit ball check valve with female ends for solvent welding, BS series EPDM Code

 Open the catalog to page 6
SXE-SSE DN 10÷50-7

Easyfit ball check valve with female ends for solvent welding, ASTM series EPDM Code EPDM Code Easyfit ball check valve with female ends, NPT thread Easyfit ball check valve with female ends for solvent welding, JIS series EPDM Code

 Open the catalog to page 7
SXE-SSE DN 10÷50-8

Easyfit ball check valve with female ends, JIS thread EPDM Code Easyfit ball check valve with PE100 SDR 11 male ends for butt welding or electrofusion welding (CVDE) d EPDM Code

 Open the catalog to page 8
SXE-SSE DN 10÷50-9

Easyfit spring check valve with female ends for solvent welding, metric series EPDM Code Easyfit spring check valve with BSP threaded female ends EPDM Code Easyfit spring check valve with female ends for solvent welding, BS series EPDM Code

 Open the catalog to page 9
SXE-SSE DN 10÷50-10

Easyfit spring check valve with female ends for solvent welding, ASTM series EPDM Code Easyfit spring check valve with female ends, NPT thread EPDM Code Easyfit spring check valve with female ends for solvent welding, JIS series EPDM Code

 Open the catalog to page 10
SXE-SSE DN 10÷50-11

Easyfit spring check valve with female ends, JIS thread EPDM Code Easyfit spring check valve with PE100 SDR 11 male end connectors for butt welding or electrofusion (CVDE) d EPDM Code

 Open the catalog to page 11
SXE-SSE DN 10÷50-12

ACCESSORIES CVDE Long spigot PE100 end connectors for joints with electrofusion fittings or for butt welding d Easyfit multifunctional handle for union nut tightening SXE-SSE DN 10÷50 Kit for union nut tightening adjustment and ball seat carrier for Easyfit DN 10÷50 valves. Union nuts tightening torque* Seat carrier tightening torque* *calculated in ideal installation conditions

 Open the catalog to page 12
SXE-SSE DN 10÷50-13

Customisation set and label printing for Easyfit handle made up of precut adhesive sheets and software for guided label creation. SXE and SSE DN 10÷50 Easyt valves are equipped with a customisable Labelling System. This system lets you create special labels to affix to the valve body. This makes it extremely easy to apply company logos, identication serial numbers or service indications such as, for example, the valve function in the system, the transported uid, but also specic information for customer service, such as the customer name or installation date or location on the valves. The specic...

 Open the catalog to page 13
SXE-SSE DN 10÷50-14

EXPLODED VIEW 3 ■ Socket seal O-Ring 6 • Transparent protection plug 8 • Gland packing ring 9 SXE ■ Ball seat O-Ring (EPDM, 10 • Ball seat carrier 11 • Radial seal O-Ring 12 • Spring (Stainless STEEL* * Also available made of Hastelloy C276 or A316 PTFE encapsulated (for DN 40 and DN 50 only) The component material and quantity supplied are indicated in the parentheses

 Open the catalog to page 14
SXE-SSE DN 10÷50-15

SXE valves do not require maintenance in normal operating conditions. In the event of leaks or wear, before performing maintenance, cut-off fluid upstream from the valve and make sure it is de-pressurised (downstream drain if necessary). 1) Reconstruct the valve following the exploded view on the previous page 1) Fully drain residual liquid that could be aggressive for the operator and, if possible, circulate water to internally clean the valve. 2) To easily unscrew the union nuts when dismounting, use the Easyfit multifunctional handle (supplied as an accessory) (fig. 4) or Easytorque kit (fig....

 Open the catalog to page 15
SXE-SSE DN 10÷50-16

INSTALLATION SXE-SSE valves can be installed both vertically (upward ow) or horizontally (SXE with a minimum 0.2 bar back pressure). Before proceeding with installation. please follow these instructions carefully: 1) Check that the pipes to be connected to the valve are aligned in order to avoid mechanical stress on the threaded joints. 2) Unscrew the union nuts (1) from the body (4) and insert them in the pipe segments. 3) Solvent weld or screw the end connectors (2) onto the pipe segments. 4) Position the valve body between the end connectors (g. 9). 5) Fit the union nuts on the valve body...

 Open the catalog to page 16

All FIP - Formatura Iniezione Polimeri catalogs and technical brochures

  1. FLS

    228  Pages

  2. SXE-SSE 2024

    13  Pages

  3. PP-H

    254  Pages

  4. PVC-U

    460  Pages

  5. FS - FC

    16  Pages

  6. S1 - S2

    12  Pages

  7. PVC-U Fittings

    114  Pages

  8. FE DN 40÷200

    14  Pages

  9. VKD DN 10÷50

    16  Pages

  10. TKD Dual Block

    14  Pages

  11. DK DN

    16  Pages

  12. DK CP

    45  Pages

  13. DK DN 15÷65

    16  Pages

  14. DK/CP DN 15÷20

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.