Technical catalogue Measuring and control instrumentation
Open the catalog to page 1System selection guide 3 1. Monitor for measurement and control of flow, FLSpH/ORP and conductivity FLS M9.02 Flow monitor and transmitter 11 FLS M9.00 Two -wire flow monitor and transmitter 15 FLS M9.20 Battery powered flow monitor 19 FLS M9.05 Conductivity monitor and transmitter 27 FLS M9.06 FLSpH/ORP monitor and transmitter 31 FLS M9.03 Dual parameter flow monitor and transmitter 35 FLS M9.07 Dual parameter conductivity and flow monitor and transmitter 39 FLS M9.08 Dual parameter flow and FLSpH/ORP monitor and transmitter 43 FLS M9.10 Dual parameter analogue signal monitor and transmitter...
Open the catalog to page 34. Bulb and Flat pH/ORP electrodes with Epoxy, C PVC, Ryton or Glass Body FLS pH/ORP 200 Epoxy body bulb electrode 131 FLS pH/ORP 400 Glass body bulb electrode 135 FLS pH/ORP 600 C-PVC body Flat-surface electrode 139 FLS pH 800 Ryton Body Flat Surface Electrode 145 Installation & Operating Guidlines for pH/ORP Electrodes 150 5. Potentiometric and Inductive Conductivity Sensors FLS CI50-200 Graphite or platinum conductivity sensor 155 FLS CI00-301 STAINLESS STEEL conductivity sensor 161 FLS C6.30 Inductive conductivity transmitter 167 Installation & Operating Guidelines for Conductivity Sensors...
Open the catalog to page 4This section provides some tips for selecting the right instruments for specific applications and liquids. Clarifying the following aspects is essential to choose the correct system and achieve maximum performance. • Measurement range • Pipe materials, sizes and standards • Type of liquid (to assess chemical compatibility) • Temperature and pressure requirements • Instrumental performance required By examining the table of applications it is possible to establish the family of sensors suitable for a specific process. If you need more information, you can also refer to the Technical Information...
Open the catalog to page 5• = Most convenient option
Open the catalog to page 7MONITOR FOR MEASUREMENT AND CONTROL OF FLOW, PH/ORP AND CONDUCTIVITY High visibility display and quick calibration system for performance optimisation
Open the catalog to page 11INSTALLATIONS AND DIMENSIONS COMPACT MOUNTING (FOR INSTRUMENTS M9.02, M9.00 AND M9.20) PANEL MOUNTING (FOR INSTRUMENTS M9.02, M9.00 AND M9.20) PANEL MOUNTING (ALL MONITORS EXCEPT M9.02, M9.00 AND M9.20) WALL MOUNTING
Open the catalog to page 12Flow monitor and transmitter
Open the catalog to page 13FLS M9.02 is an extremely efficient flow monitor and is designed to convert the frequency signal of flow sensors into flow rate. The M9.02 monitor is equipped with a large 4" graphic display which shows measured values clearly and a lot of other useful information. Moreover, due to a multicolour display plus a powerful backlight, measurement status can be determined easily from afar too. A tutorial software guarantees a mistake-proof and fast set up of every parameter. Calibration can be performed by indicating the installation features or using a reference value through a new "in-line calibration"....
Open the catalog to page 14Rear view of electrical connections
Open the catalog to page 15M9.02.PX - M9.02.WXFlow Monitor and Transmitter Code S.S.R: solid state relay / mech relay.: mechanical relay S.S.R: solid state relay / mech relay: mechanical relay
Open the catalog to page 162-Wires Flow Monitor and Transmitter
Open the catalog to page 17FLS M9.00 is a powerful flow monitor and transmitter based on 2-wire technology, designed to convert the frequency signal of flow sensors into flow rate. The M9.00 monitor is equipped with a large 4" display which shows measured values clearly. In addition, the standard backlighting further improves the visibility of the display. The main parameters can be configured with a first wizard. A reference flow rate can be used for recalibration or for an alignment through an intuitive "in-line calibration". A 4-20 mA 2-wire analogue signal combined with a solid-state relay allows you to remotely manage...
Open the catalog to page 18Rear view of electrical connections
Open the catalog to page 19M9.00.PX - M9.00.WX2-wires Flow Monitor and Transmitter Code S.S.R: solid state relay S.S.R: solid state relay
Open the catalog to page 20Battery powered flow monitor
Open the catalog to page 21FLS M9.20 is a smart battery-powered flow monitor designed to convert the frequency signal of FLS sensors into flow rate. The M9.20 monitor is equipped with a high range lithium battery that also powers the sensors. The large 4" display shows the measured values with extreme clarity. The main parameters can be configured with a first wizard. For calibration or alignment using an extremely user-friendly in-line calibration procedure, a reference flow rate can be used. A safety icon notifies you when it is time to replace the battery and the instrument automatically stores all the main parameters....
Open the catalog to page 22ELECTRICAL CONNECTIONS Rear view of electrical connections
Open the catalog to page 23M9.20.PX - M9.20.WXBattery Powered Flow Monitor Code
Open the catalog to page 24FLS M9.50 is a device dedicated to the accurate batching or mixing operations of liquids. A 4" wide full graphic display shows measured values clearly together with a lot of other useful information. The colour display and its powerful backlight allow an easy control of batching process even from very long distance. The software provides assistance to minimise errors and speed up the configuration of all settings. Advanced options are also available to increase accuracy and reduce transfer times. The possibility of setting various volumes (up to 10 transfers) according to certain calibration...
Open the catalog to page 26Rear view of electrical connections
Open the catalog to page 27S.S.R: solid state relay / mech relay.: mechanical relay
Open the catalog to page 28FLS M9.05 Conductivity Monitor and Transmitter
Open the catalog to page 29The FLS M9.05 conductivity monitor and transmitter is a powerful device designed for a wide range of applications, including ultrapure water production. A 4" wide full graphic display shows measured values clearly together with a lot of other useful information. Moreover, due to the multicolor bright backlight, measurement status can be determined easily also from very long distance. A tutorial software guarantees a mistake-proof and fast set up of every parameter. The measured values can be displayed as resistivity or TDS, depending on the needs. The freely settable cell constant allows all...
Open the catalog to page 3013 Pages
254 Pages
6 Pages
460 Pages
16 Pages
12 Pages
28 Pages
28 Pages
28 Pages
114 Pages
14 Pages
16 Pages
12 Pages
14 Pages
16 Pages
16 Pages
16 Pages
20 Pages
16 Pages
45 Pages
6 Pages
17 Pages
16 Pages
20 Pages
24 Pages
6 Pages
16 Pages
2 Pages
16 Pages
246 Pages
14 Pages
198 Pages
165 Pages
141 Pages
14 Pages
12 Pages
12 Pages