FITTINGS PVC-U - 1

Technical catalogue Pipe and fittings in PVC-U

Open the catalog to page 1
FITTINGS PVC-U - 3

Contents PVC-U General characteristics Reference standards Approvals and quality marks Solvent welding instructions Installation instructions for threaded joints Main properties ISO-UNI pipe PVC-U pressure pipe ISO-UNI fittings Solvent weld fittings, metric series ISO-BSP fittings Adaptor fittings Threaded fittings Solvent weld and threaded fittings

Open the catalog to page 3
FITTINGS PVC-U - 4

General characteristics PVC-U Developed in 1930 in Germany, PVC-U (rigid polyvinyl chloride - unplasticized) is obtained through the polymerization of a vinyl chloride monomer. The presence of chlorine in the PVC-U molecule results in a high performance resin, in terms of thermal stability and chemical and mechanical resistance, up to temperatures of 60° C. The different formulations obtained by adding suitable additives and stabilizers render the PVC-U the most versatile of all plastic materials, allowing it to be adapted to many applications involving fluids under pressure. PVC-U...

Open the catalog to page 4
FITTINGS PVC-U - 5

Density Test method ISO 1183 - ASTM D792 Unit of measurement g/cm3 Value 1,38 Modulus of elasticity Test method ISO 527 Unit of measurement MPa = N/mm2 Value 3200 Charpy impact strength at 23°C Test method ASTM D256 Unit of measurement KJ/m2 Value 5-8 Ultimate elongation Test method ISO 527 Unit of measurement % Value 50 Shore hardness Test method ISO 868 Unit of measurement Shore D Value 80 Tensile strength Test method ISO 527 Unit of measurement MPa = N/mm2 Value 50 VICAT softening point (B/50) Test method ISO 306 Unit of measurement °C Value 76 Heat distortion temperature HDT (0.46...

Open the catalog to page 5
FITTINGS PVC-U - 6

Reference standards PVC-U Production of the PVC-U lines is carried out according to the highest quality standards and in full compliance with the environmental restrictions set by the applicable laws in force and in accordance with ISO 14001. All products are made in accordance with the quality guarantee system in compliance with ISO 9001. l ASTM D 1784 cl. 12454 Rigid PVC-U compounds (for industrial applications). l ASTM D 1785 Standard specification for pipes in PVC, Sch. 40-80-120 l ASTM D 2464 Standard Specification for Threaded Poly Vinyl Chloride (PVC) Plastic Pipe Fittings l ASTM D...

Open the catalog to page 6
FITTINGS PVC-U - 7

l JIS K 6741 PVC-U pipes l JIS B 0203 Tapered pipe threads l JIS K 6743 PVC-U pipe fittings for water supply systems l UNI 11242 Solvent welding of PVC-U and PVC-C pipes, fittings and valves l ANSI B16.5 Pipe, flanges and flanged fittings-NPS 1/2 to NPS 24 mm / inch l EN 558-1 Industrial valves - face-to-face and centre-to-face dimensions of metal valves for use in flanged pipe systems - Part 1: PN designated valves l EN ISO 16135 Industrial valves - Ball valves of thermoplastic material l EN ISO 16136 Industrial valves - Butterfly valves of thermoplastic material l EN ISO 16137 Industrial...

Open the catalog to page 7
FITTINGS PVC-U - 8

Approvals and quality marks l ABS The FIP PVC-U and PVC-C systems are recognised as suitable for conveying and treating sanitary and conditioning water on board ships and other units classified by the American Bureau of Shipping (ABS) l ACS France (Attestation de conformité Sanitaire) Suitability of PVC-U and PVC-C for drinking water l BSI (British Standards Institution UK) Suitability of PVC-U for food and beverage applications l Bureau Veritas (France) Suitability of PVC-U and PVC-C for conveying and treating sanitary and conditioning water in the maritime sector l CSTB PVC-U fittings and...

Open the catalog to page 8
FITTINGS PVC-U - 9

l WRAS (Water regulations advisory scheme - UK) Suitability of PVC-U and PVC-C for transporting potable water l RMRS FIP PVC-U fittings and valves have been recognised as suitable for conveying, treating domestic and air conditioning waters on board ships and other units classified by the Russian Maritime Register of Shipping l DNV-GL FIP PVC-U and PVC-C systems have been recognised as suitable for conveying, treating domestic and air conditioning waters on board ships and other units classified by DNV-GL l NIZP FIP PVC-U fittings and valves have been recognised as suitable for conveying...

Open the catalog to page 9
FITTINGS PVC-U - 10

del polimero PVC-U in apposita miscela di solventi, che rammolliscono le pareti delle teristiche di resistenza chimica e meccanica assimilabili a quelle delle tubazioni e dei tubazioni e dei raccordi, per poi effettuarne la saldatura cedendo il materiale in essi raccordi impiegati. E’ noto che i collanti/adesivi devono essere selezionati in con caratcontenuto. La saldatura chimica consente di ottenere giunzioni permanenti funzione del tipo di di resistenza chimica dameccanica assimilabilila natura delle tubazioni e dei teristiche resina termoplastica e saldare, poiché varia a quelle dei...

Open the catalog to page 10
FITTINGS PVC-U - 11

Per maggiori dettagli consultare la tabella “Caratteristiche e dimensioni dei pennelli - applicatori”. Si consiglia comunque, di usare un applicatore/pennello con dimensioni non inferiori alla metà del diametro del tubo. L’applicazione del collante sul tubo e raccordo, deve essere estesa per l’intera lunghezza delle superfici di accoppiamento: - per l’intera lunghezza di incollaggio del tubo, segnata in precedenza sulla sua superficie esterna (fig. 6) - per l’intera profondità del bicchiere del raccordo fino alla battuta interna (fig.7) 6) Inserire immediatamente il tubo nel raccordo per...

Open the catalog to page 11
FITTINGS PVC-U - 12

LUNGHEZZA DI INSERZIONE INCOLLAGGIO E SMUSSO DEL TUBO Socket depth, cement and chamfer length External diameter Diametro esterno de (mm) Metric series Serie Metrica de (mm) de (mm) 16 BS series BS Serie (inch) (inches) 3/8” Cementing lengthincollaggio Chamfer Lunghezza di L (mm) L (mm) Sm (mm) Serie Metrica Metric series CARATTERISTICHE E DIMENSIONI DEI PENNELLI - APPLICATORI Characteristics and dimensions of brushesDiametro esterno Tipologia e dimensioni del Pen applicators o Applica de (mm) Type and dimensions of Brush 3/8” - 3/4” or Applicator 1” - 2” 2” 1/2 - 6” Round (8 - 10 mm)...

Open the catalog to page 12
FITTINGS PVC-U - 13

Warnings l In the case where the external diameter of the pipe and the internal diameter of the fitting are at opposite extremes of their tolerance values, the dry pipe cannot be inserted in the dry socket of the fitting. Insertion will only be possible after having applied the Cleaner and Solvent Cement to both parts to be joined. l The solvent cement is manufactured from the same PVC resin used for the production of the pipes, fittings and valves. Unless otherwise specified, the solvent cement used on the surfaces to join must also be usable with the following tolerances: - maximum...

Open the catalog to page 13

All FIP - Formatura Iniezione Polimeri catalogs and technical brochures

  1. SXE-SSE

    24 Pages

  2. FS - FC

    16 Pages

  3. S1 - S2

    12 Pages

  4. PVC-U Fittings

    114 Pages

  5. FE DN 40÷200

    14 Pages

  6. VKD DN 10÷50

    16 Pages

  7. TKD Dual Block

    14 Pages

  8. DK DN

    16 Pages

  9. DK CP

    45 Pages

  10. DK DN 15÷65

    16 Pages

  11. PVDF System

    141 Pages