FINNtrometer™

FINNtrometer™

FINNtrometer™

Product catalog summary
Applications
  • Used in automotive, horticulture, medical, aeronautical, industrial, lighting, and information technology sectors.
  • Essential when CIE xy, CIE uv, CCT, and dominant wavelength are critical.
  • Ensures reliable quality control and precise measurements.
  • Suitable for testing pulsing, bright to dim LEDs across ultraviolet to near-infrared spectrums.
  • Applicable in functional and in-circuit test environments on any test platform.
  • Ideal for testing multiple LEDs and large quantities.
  • Perfect for setups where frequency and voltage measurements are not feasible.
Features
  • Accurate measurement of CIE xy, CIE uv, Color Temperature (CCT), and Dominant Wavelength.
  • Eliminates the need for additional hardware for frequency or voltage readings.
  • Simple serial command and response interface, adaptable to custom software or NI LabView.
  • Easy installation with USB or RS232 Serial connection, featuring built-in reverse and overvoltage protection.
  • Fiber optics are 1.28 mm in diameter, suitable for closely spaced LEDs.
  • Available with a 90-degree tip fiber optic cable.
  • Compact module easily mounts in an ICT fixture or functional test station.
  • No custom software needed; plug-n-play module for testing 1 to 12 LEDs, expandable to 254 LEDs with a single USB or Serial cable.
Ordering Information
  • Modules available for testing 4, 8, or 12 LEDs with part numbers TCFT_4Mod, TCFT_8Mod, and TCFT_12Mod respectively.
  • Fiber optic cable assemblies available in 18" straight, 24" straight, and 18" 90-degree configurations.
Principle of Operation

The FINNtrometer™ uses advanced LED color and intensity measurement capabilities within a custom sensor package. It allows simultaneous testing of multiple LEDs without individual power requirements, reducing fixture considerations and costs. The module includes multi-color sensors and a microprocessor, with fiber optic cables measuring color and intensity, sending data via USB or serial interface. Modules can be daisy-chained to test up to 254 LEDs.

Set-Up
  • USB: Connect cable and align fiber optic in front of LEDs. Utilizes USB power, no external supply needed.
  • Serial: Requires power, ground, transmit, and receive connections. Needs 5v to 16v power supply.
  • Optics: Offers three fiber optic options with press fit plug and metal shrouded tip for LED testing.
Dimensions

Module dimensions are 2.2" x 4.5" with 0.187" diameter holes.

See more

Catalog excerpts

FINNtrometer™-1

CIE xy INTENSITY WAVELENGTH CIE xy WAVELENGTH INTENSITY COLOR TEMPERATURE CCT COLOR TEMPERATURE LEDWAVELENGTH CIE xy LED WAVELENGTH CIE CCT LED COLOR TEM xy WAVELEN CIE xy FINNtrometer WAVELENGTH CIE xy INTENSITY WAVELENGTH CIE xy WAVELENGTH INTENSITY ATURE CCT COLOR TEMPERATURE CCT COLOR TEMPERATURE LEDWAVELENGTH CIE xy LED WAVELENGTH CIE CCT LED COLOR TE xy WAVELE CIE xy INTENSITY LED Color Testing Sensors INTENSITY Plug-n-Play COLOR TEMPERATURE CCT COLOR TEMPERATURE LEDWAVELENGTH CIE xy LED WAVELENGTH CIE CCT LED COLOR TEM xy WAVELEN CIE xy INTENSITY WAVELENGTH CIE xy WAVELENGTH INTENSITY COLOR TEMPERATURE LEDWAVELENGTH CIE xy LED WAVELENGTH CIE CCT LED COLOR TE xy WAVELE FINNtrometer is a plug-n-play ATURE CCT COLOR TEMPERATURE CCT module for testing 1 to 12 LEDs ™ INTENSITY CIE xyand can be daisy chained to test up to 254 LEDs with a single USB or Serial cable. A P P L I C AT I O N S • utomotive, Horticulture, Medical, Aeronautical, A Industrial, Lighting, Information Technology. • uick and easy installation with the flexibility of either a Q USB or RS232 Serial connection with built-in reverse and overvoltage protection. • hen CIE xy, CIE uv, CCT and dominant wavelength W are critical. • iber Optics are 1.28 mm in diameter, allowing for testing F of very closely spaced LEDs. • hen quality control demands reliable, unerring accuracy W and when clear cut measurements are vital. • 90 degrees tip fiber optic cable available. • or pulsing, bright to very dim LEDs – visible light from F ultraviolet to near infrared. • unctional and in-circuit test environments, on any F test platform. • or use in testing multiple LEDs and excellent for large F quantities of LEDs. • ompact module is easily mounted in an ICT fixture C or functional test station. • No custom software needed. O R D E R I N G I N F O R M AT I O N MODULES D E SC R I P TI ON 4 LED FINNtrometer™ • deal for functional test set ups and MDA stations where I frequency and/or voltage measurements are not possible. PART NUMBER (Tests up to 4 LEDs) (Tests up to 8 LEDs) F E AT U R E S • ccurate measurement of CIE xy, CIE uv, Color A Temperature (CCT) and Dominant Wavelength. • liminates the need for additional measuring hardware for E Frequency or Voltage readings. PART NUMBER • imple serial command and response interface that can S be used manually or adapted to custom software or NI LabView. 18" Straight Fiber optic cable assembly 24" Straight Fiber optic cable assembly 18" 90 Degrees Fiber optic cable assembly P 224.662.0383 | E [email protected] www.FINNTestElectronics.com U.S. Patent Nos. 10,094,877; 10,302,496; 6,490,037; 7,023,554; 7,227,639; and

 Open the catalog to page 1
FINNtrometer™-2

CIE xy INTENSITY WAVELENGTH CIE xy WAVELENGTH INTENSITY COLOR TEMPERATURE CCT COLOR TEMPERATURE LEDWAVELENGTH CIE xy LED WAVELENGTH CIE CCT LED COLOR TEM xy WAVELEN FINNtrometer WAVELENGTH CIE xy INTENSITY WAVELENGTH CIE xy WAVELENGTH INTENSITY COLOR TEMPERATURE CCT COLOR TEMPERATURE LEDWAVELENGTH CIE xy LED WAVELENGTH CIE CCT LED COLOR TE xy WAVELE LED Color INTENSITY WAVELENGTH WAVELENGTHTesting Sensors Plug-n-Play CIE xy COLOR TEMPERATURE CCT COLOR TEMPERATURE LEDWAVELENGTH CIE xy LED WAVELENGTH CIE CCT LED COLOR TEM xy WAVELEN INTENSITY module(s) may be implemented into functional, INTENSITY...

 Open the catalog to page 2

All Finn Test Electronics catalogs and technical brochures

  1. Mega FINN™

    13  Pages

  2. FINN®

    11  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.