Operating Principle: Thermal dispersion flow switches measure liquid velocity using a probe with a heating sensor and a temperature sensor. The temperature difference between these sensors inversely correlates with flow velocity. The device is durable, sensitive, accurate, and suitable for various conditions, including corrosive and hazardous environments. It can be calibrated for different liquid densities and impurities and is easy to install with customizable probe lengths and three output signal options.
Features and Applications: The flow switch is applicable in industries such as petrochemicals, hydroelectric plants, shipyards, HVAC systems, steel, food and beverage, pharmaceuticals, optics, and semiconductors. It is suitable for any liquid-carrying pipes where flow measurement is needed.
Product Specifications: The flow switch operates within a range of 1-150 cm/s for water and 3-300 cm/s for oil. It supports operating temperatures from -20 to 80°C and pressures up to 100 bar. The device is available in models with different housing materials (SUS304, 316L, 316) and protection levels (IP65, IP67). It offers various alarm outputs and connection threads.
Installation Guidelines: Installation requires using a waterproof gasket and ensuring the pipe is bubble-free. For pipes not completely filled, installation should be from the bottom. A filter upstream can reduce impurities. The device can be installed from various angles for optimal sensitivity and response speed.
Wiring and Connections: The document provides detailed wiring diagrams for NPN, PNP, and relay output types, specifying wire colors and connections for power, grounding, and output.
Ordering Information: The document outlines how to order different models based on material, output type, size specification, connection type, and probe length. Customized lengths are available upon request.
Sectional Drawings: The document includes drawings of the flow switch components, such as the paddle, axis, reed switch, spring, magnet, and housing, illustrating the switch's operation when liquid flow is detected.
Global Network: FineTek has offices and factories in Taiwan, China, Singapore, the U.S., and Germany, providing contact information for each location.
See more

Catalog excerpts

SP Series Thermal Dispersion Flow Switch-2

PRODUCT INTRODUCTION OPERATING PRINCIPLE Thermal dispersion flow switches measure the velocity of a liquid inside a pipe or channel. The switch’s probe contains two key components – a heating sensor and temperature sensor. The heating sensor is positioned closest to the flowing liquid and provides a consistent heat. The temperature sensor measures the temperature emitted from the heating sensor. When liquid is flowing, there is a temperature difference between the two sensors. The temperature difference has an inverse relationship with the flow velocity (fast flowing liquids will result in greater...

 Open the catalog to page 2
SP Series Thermal Dispersion Flow Switch-3

PRODUCT SPECIFICATIONS SP202-9-99-9-9 High Temp. model Ambient temp. Operating temp. Model Measuring range Open Collector : NPN / PNP (<400mA) Relay : 1A/30Vdc, 0.3A/125Vac (NO or NC) Alarm output Operating pressure Flow velocity below set point- Red LED on, Open Flow velocity equals set point- Yellow LED on, Close Flow velocity above set point- 4 Green LED to indicate flow speed, Close Wetted part Protection level Warm-up time Connection thread Operating voltage Power consumption 3-wire NPN/PNP Power-brown Grounding-blue Output-black

 Open the catalog to page 3
SP Series Thermal Dispersion Flow Switch-4

PRODUCT SPECIFICATIONS Model Measuring range Ambient temp. Operating temp. Alarm output Operating pressure Housing Wetted part Protection level Open Collector : NPN / PNP (<400mA) Relay : 1A/30Vdc, 0.3A/125Vac (NO or NC) 100 bar (max.) Flow velocity below set point- Red LED on, Open Flow velocity equals set point- Yellow LED on, Close Flow velocity above set point- 4 Green LED to indicate flow speed, Close PC SUS304 / 316 / 316L IP65 Warm-up time Connection thread Operating voltage Power consumption 3-wire NPN/PNP Power-brown Grounding-blue Output-black Sensitivity and Alarm setting not available....

 Open the catalog to page 4
SP Series Thermal Dispersion Flow Switch-5

PRODUCT SPECIFICATION SP210 Stainless Steel model Cert. Number GYJ12.1521x Model SP170-(½) Explosion Proof model SP171-(½) Explosion-proof extension model Measuring range Ambient temp. Operating temp. Alarm output Operating pressure 100 bar (max.) Flow velocity below set point- Red LED on, Open Flow velocity equals set point- Yellow LED on, Close Flow velocity above set point- 4 Green LED to indicate flow speed, Close Wetted part Protection level Warm-up time Connection thread Operating voltage Power consumption 60mA (max.) 5-wire Relay Output Power- red Grounding- black COM- white NC- yellow...

 Open the catalog to page 5
SP Series Thermal Dispersion Flow Switch-6

INSTALLATION 4. Screw tightly to avoid. Can be installed from various angles. For best sensitivity and response speed, please install using in the demonstrated in Fig. 4 5. Installing a filter upstream can decrease liquid impurities which can reduce wear and tear on the switch. 1. Use the water-proof gasket provided 2. The distance "a" should be 4 times larger than the switches’ screw diameter. (Fig. 1) 3. The pipe is bubble free for proper functioning. (Fig. 2) 4. For not-completely-filled pipes, install from the bottom. The liquid level needs to be higher than the probe height. (Fig. 3)

 Open the catalog to page 6
SP Series Thermal Dispersion Flow Switch-7

Fig. 5 Wire terminal diagram (NPN, PNP and 1A relay output type) Fig. 7, NPN output type wiring Brown Blue Green Black Fig. 10, Relay output type wiring (NO) Fig. 8, PNP output type wiring Brown Blue Green Black Fig. 11, Relay output type wiring (NC) SCREW TABLE Black White Yellow Blue Fig. 9, Relay output type wiring

 Open the catalog to page 7
SP Series Thermal Dispersion Flow Switch-8

SP29 9- 9 - 99 - 9- 9 - ( 9999 ) Model Description 0 : Compact model 1 : Stainless Steel model f 70X78 (for SPDT 5A/250Vac ) 2 : Economy model ( Plastic Housing ) Probe Type 0: Standard model 1: Probe Extension model 2: 120BC High Temperature model ( Except SP220 ) Output N: NPN (current limit: 400mA) P: PNP (current limit: 400mA) A: Relay 1A/30Vdc (NO) B: Relay 1A/30Vdc (NC) C: Relay 5A/250Vac (SPDT) (for SP210/ SP211/ SP212) Cable Wire Length(unit: m) 2: 2m Length L (Unit: mm) ※ Length tolerance: A5mm ※ Dimensions are subject to change ※ Customized lengths available on request * Max.200mm

 Open the catalog to page 8
SP Series Thermal Dispersion Flow Switch-9

Model Description - 70 —Explosion Proof Type Size Specification Dimensions are subject to change Customized lengths available on request * Max.200mm

 Open the catalog to page 9
SP Series Thermal Dispersion Flow Switch-10

PADDLE TYPE FLOW SWITCH SECTIONAL DRAWINGS Flow Switch can detect liquid movement in pipes. When the liquid is static or nonexistent, the spring is fully extended pulling the magnet downward and opening the switch. As flow occurs and the paddle is thrusted forward 20BC~30BC (or more) the paddle will push the magnet upward and actuate the switch (closing the circuit) The length of paddle can be adjusted to the pipe's diameter. 2. Paddle 3. Axis 4. Reed switch reed switch axis paddle MODEL: SF1800 MODEL: SF1710 Explosion proof model Standard model 70 Switch on in case of liquid flowing in pipes...

 Open the catalog to page 10
SP Series Thermal Dispersion Flow Switch-11

Housing material Operation temp. Wetted material Pressure drop allowance Repeatability tolerance Operation pressure Contact capacity FLOW CONTROL RANGE TABLE 1" Flow Volume Paddle Length Act. De-Act. Act. De-Act. Act. De-Act. Act. De-Act. Act. De-Act. 1. The paddle length is dependent on the lowest paddle point to actuate the switch. Cut the paddle at appropriate pipe size mark or wherever desired. The minimum is 1". 2. The paddle must be at a right angle to the direction of flow 3. The FLOW mark on the screw must be parallel to the pipe. 4. Before installing the unit to a tee pipe, apply thread...

 Open the catalog to page 11
SP Series Thermal Dispersion Flow Switch-12

Global Network Germany China U.S. Taiwan North America FINETEK CO., LTD. - Taipei Head Quarter No.16, Tzuchiang St., Tucheng Industrial Park New Taipei City 236, Taiwan TEL: 886-2-2269-6789 FAX: 886-2-2268-6682 EMAIL: [email protected] APLUS FINETEK SENSOR INC. - US Office 355 S. Lemon Ave, Suite D, Walnut, CA 91789 TEL: 1 909 598 2488 FAX: 1 909 598 3188 EMAIL: [email protected] FineTeK GmbH - Germany Office Frankfurter Str. 62, OG D-65428 Ruesselsheim, Germany TEL: +49-(0)6142-17608-0 FAX: +49-(0)6142-17608-20 EMAIL: [email protected] FINETEK CO., LTD. - I-Lan Factory TEL: 886-3-990-9669 FAX:...

 Open the catalog to page 12

All FineTek Co., Ltd. catalogs and technical brochures

  1. Thermocouple

    12  Pages

  2. Pressure Switch

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.