Group: FINETEK
Catalog excerpts
Magnetic Float Level Switch
Open the catalog to page 1PRINCIPLE The single unit or multiple reed switch units are housed tightly in stainless steel or engineering plastic stem, and the permanent magnet is sealed into the middle of the specified float ball(s). You can mount the float ball to penetrating through the stem, then the liquid buoyancy will deliver the float ball up and down at the specified position by graduating rings. When the float internal magnet approaches the reed switch, it will actuate the reed switch contact point to create an open or close circuit. We can apply such on-off output signals to reach liquid level controlling...
Open the catalog to page 2APPLICATIONS Shipbuilding Industry, Generator Facilities, Petrochemical Industry, Food/Beverage Industry, Waste Water/Water Purified Facilities, Electronic Industry, Dyeing and Finishing Industry, Chemical Industry, Rubber/ Plastic Industry, Hydraulic. SPECIFICATION Tube Type Switching Switching Contact from Capacity Max. ※Reed switches of UL approval are 240Vac/ 200Vdc, 50w,0.5A. APPLICATION FIELDS OF FLOAT Environments Working Temp. Pressure Rating =Not good
Open the catalog to page 3CHEMICAL RESISTANCE Excellent O Good A Fair X Corroded Sulfuric Acid Chromic Acid Plastic RubberStainless
Open the catalog to page 4• Excellent O Good A Fair X Corroded
Open the catalog to page 5CONTACT PROTECTION CIRCUITS INDUCTIVE LOADS When using a reed switch with inductive loads such as motors, relays, solenoids, etc., The contact will be subjected to a high induced voltage during opening of the contact (load circuit). (Fig.1) Such high induced voltage (transients) may cause damages to the reed switch or significantly reduce its life. Therefore, protective circuits such as: RC (snubber), varistors or clamping diodes are recommended.(refer to Fig.1) Inductive load Inductive load . It is prohibited to connect directly with any solenoid valve, motor or magnetic switch. CAPACITIVE...
Open the catalog to page 6HOUSING SPECIFICATION Material : Aluminum Material : PP+Fiber Material : Aluminum Material : Aluminum Material : Aluminum Enclosure : INERIS 09 ATEX 0049 Material : Aluminum Enclosure : INERIS 09 ATEX 0049 *For flow switch series. Material : Aluminum Remark 1 : Cable conduit is optional. Contact us if needed. Material : Aluminum *For side-mounting float series. *For side-mounting float series. Cable Conduit Exdiic
Open the catalog to page 7FLOAT SPECIFICATIONS Max. Pressure Weight 2 (kg/cm ) (g) white black white PP / black
Open the catalog to page 8ORDER SPECIFIED THE PROPERTIES BETWEEN LIQUID AND FLOAT Please choose the proper float subject to above independent specified terms and chemical characters. 4. Chemical: Please use plastic float for acid/ alkaline corrosion of chemical applications. PVDF float is noted for high temperature cases. 1. Temperature: PVDF Max. 120BC, PP Max. 80BC, SUS304/ 316 Max. 200BC 2. Pressure: SUS304/ 316 Float, Max. 35kg/cm2 Engineering plastic, Max. 5kg/cm2 (S10 float Max. 50kg) 3. Viscosity: Please choose smaller S.G. with greater diameter floats to cope with high viscosity liquid applications. 5....
Open the catalog to page 9HOW TO MAKE YOUR ORDER T P: Pipe Shield R: Sensor T: Test Rod Contact Form A: SPST C: SPDT G: 1 float 3 points F: 1 float 2 points : No contact Stem Code size Code size Material 0: f8 PP 6: f16 1: f8 SUS304 7: f17.2 2: f8 PVC 8: f12.7 3: f9.5 SUS304 9: f12.7 4: f12.7 SUS304 5: f17.2 P.P. Connection Type Housing Type B: AL. (Big space) C: PP (Anti-acidity) D: Aluminum E: AL. (Small space) G: PC (Anti-acidity) D: Aluminum K: AL. N: SUS304 or SUS316 P: Plastic IP65 -: Without housing 2: Without housing (Side Mounting) FC: Plastic (Stem) FD: Metal (Stem) Code size A: f8 B: f9.5 C: f12.7 D:...
Open the catalog to page 10ANTI-CORROSION SCREW TYPE / FLANGE TYPE Housing material apply by PP, wet portion material options in PP, PVDF, specially applicable for chemical applications against corrosive environments. Wetted PartsPVDF Wetted PartsPP Order information Type Housing Type ※FCC(FQ) & (FN)2" flange/thread are available,too. Float Quantity Float Type Pipe Diameter Connection Flanges Wetted PartsPVDF Wetted PartsPP
Open the catalog to page 11STANDARD FLANGE TYPE The housing complies with the IP65 rating and can therefore be used in outdoor environment. Order information Housing Type Float Type Float Quantity Pipe Diameter Connection Flanges
Open the catalog to page 12STANDARD SCREW TYPE The housing complies with the IP65 rating and can therefore be used in outdoor environment. Order information Connection Flanges Pipe Diameter Float Type Float Quantity
Open the catalog to page 13SCREW TYPE / FLANGE TYPE The housing complies with the IP65 rating and can therefore be used in outdoor environment. Order information Type Housing Type Pipe Diameter Float Type Float Quantity Connection Flanges
Open the catalog to page 14ENCLOSURE EXPLOSION PROOF FLANGE TYPE Type Order information Housing Type Connection Flanges Pipe Diameter Float Type Float Quantity SCREW TYPE Order information Type Housing Type Connection Flanges Pipe Diameter Float Type Float Quantity
Open the catalog to page 15VERTICAL ADJUSTMENT TYPE Applicable at tank interior pressure under 5 kg/cm2. Standard specification 80BC, special order of max. 200BC available. Switch contact: 20W/150Vac /250Vdc SPDT 50W/300Vac /350Vdc SPST 60W/220Vac /500Vdc SPST 60W/400Vac /1000Vdc SPDT Customer specified flange/ screw acceptable. This is a special design for some liquid applications requiring monitoring different actuation levels frequently. The user needs only to loose the hexagon nut, then remove the mounted screw/ flange up or down to achieve the actuated level position adjustment. Order information Connection Pipe...
Open the catalog to page 16When the Test Rod is attached to a magnetic float level switch, user could test the performance of the magnetic switch directly by pulling the handle of the test rod on the top of the switch. 1. Rod Connection: Bronze 2. Compressed Spring: Stainless Steel 3. Positioning Clip: Stainless Steel 4. Test Rod Stem: Stainless Steel
Open the catalog to page 17MARINE GRADE APPROVAL TYPE APPROVAL PROGRAM FM DM 4 S3 1 0500 A Contact Form A: SPST, C: SPDT Length: mm 0500: below 500mm 1000: 501~1000mm 1500: 1001~1500mm Float quantity Float Type Contact Form A: SPST, C: SPDT Length: mm 0500: below 500mm 1000: 501~1000mm 1500: 1001~1500mm Float quantity Float Type Pipe diameter Pipe diameter * Please specify the , 2 , C-C and L while placing an order. (Length from lower end of housing to center line of float ball) * Special term for LR Marine approval: "Environmental test has been carried out but it is not applicable to use in the ship and offshore...
Open the catalog to page 18All FineTek Co. catalogs and technical brochures
-
EFX By-Pass Level Transmitter
34 Pages
-
EPD Electromagnetic Flow Meter
28 Pages
-
Tuning Fork Level Switch
32 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Temperature Transmitter
5 Pages
-
Thermocouple
12 Pages
-
Vibrating point level switch
14 Pages
-
SA Capacitance Level Switch
18 Pages
-
SE Rotary Paddle Level Switch
15 Pages
-
EC Pressure Level Transmitter
12 Pages
-
SQ Pressure Switch
12 Pages
-
SD Optical Level Switch
2 Pages
-
FF Side Mounting Float Switch
15 Pages
-
FC/FD Mini Float Level Switch
28 Pages
-
RF-Admittance Level Switch
11 Pages
-
Optical Level Switch
13 Pages
-
Rotary Paddle Level Switch
15 Pages
-
Magnetic Float Level Transmitter
14 Pages
-
RF-Admittance Level Transmitter
15 Pages
-
Capacitance Level Switch
18 Pages
-
Vibrating Probe Level Switch
10 Pages
-
Pressure Level Transmitter
12 Pages
-
EF By-Pass Level Transmitter
23 Pages
-
Air Hammer/Pneumatic Vibrator
16 Pages
-
Mini Float Level Switch
28 Pages
-
Pressure Switch
12 Pages
-
PID+Fuzzy Temperature Controller
23 Pages
-
Cable Float Level Switch
12 Pages
-
Side Mounting Float Switch
15 Pages