The document details the EPD electromagnetic flow meter, a precision instrument for measuring the flow of non-magnetic liquids and plasma in enclosed pipes, applicable across industries like papermaking, chemical, metallurgical, and wastewater treatment.

Specifications
The flow meter operates on Faraday's law of electromagnetic induction, comprising a sensor and transmitter with excitation coils and induction electrodes. Key specifications include:
  • Enclosure protection: IP67/NEMA 4X
  • Measurement range: 0.1m/s to 10m/s
  • Accuracy: ±0.5% of reading
  • Output: 4-20mA, frequency output 2-8KHz, RS485 communication
  • Power: 110Vac, 220Vac, 24Vdc

Features
Designed for efficiency and low environmental impact, it handles liquids with fibers and solids. Features include:
  • Measurement turndown ratio of 1:100
  • Backlit display with dual isolation and memory
  • Self-diagnosis and smart detection
  • Low installation cost with minimal straight tube requirements

Material Selection
Materials for lining and electrodes are specified for different applications:
  • PTFE: Resistant to acids and salts, for strong corrosive mediums.
  • NBR: Flexible and wear-resistant, for mineral pulp.
  • Neoprene: Resistant to low acid and alkali, for water.
  • Tantalum: Corrosion-resistant, not for alkali.

Applications
Used in wastewater treatment, seawater desalination, solar energy, and food manufacturing, effective in varying liquid conditions.

Certification and Quality Assurance
FineTek's flow laboratory is certified by the Taiwan Accreditation Foundation, meeting international standards as the only Class 2 flow test laboratory in Taiwan, ensuring high accuracy and quality.
See more

Catalog excerpts

EPD Electromagnetic Flow Meter-1

Electromagnetic Flow Meter

 Open the catalog to page 1
EPD Electromagnetic Flow Meter-2

FLOW MEASUREMENT FIELD FineTek is the only inspection institution that owns a Class 2 flow test laboratory in Taiwan. With the most professional R&D and Design Team, it can design and develop high-accuracy electromagnetic flow meters. Moreover, it conducts calibration in Class 1 Flow Laboratory of the National Measurement Laboratory (ITRI Measurement Center), so as to guarantee the flow accuracy on the measurement field. FineTek’s flow laboratory has received certification from the Taiwan Accreditation Foundation and conforms to the regulations of international organizations such as ILAC and...

 Open the catalog to page 2
EPD Electromagnetic Flow Meter-3

FLOW MEASUREMENT FIELD PUMP equipment (The maximum horsepower is 110KW per unit) Weighing equipment (Max capacity for four meters calibration simultaneously in above system.) Control room & Graphical HMI The exclusive report (Each flow meter has its own calibration report)

 Open the catalog to page 3
EPD Electromagnetic Flow Meter-4

ELECTROMAGNETIC FLOW METER EPD electromagnetic flow meter is a high-accuracy flow meter manufactured based on the latest international technology. It is widely applied in papermaking, chemical industry, metallurgical industry, drainage, waste water treatment, liquid high-pressure metering, medical care, food, and environmental protection industries. It is used to measure the non-magnetic liquid and plasma in the enclosed pipe. Magnetic coil liquid Measuring pipe Electrode FEATURES Low impact on environmental matter The measurement results are not affected by the change in liquid density, viscosity,...

 Open the catalog to page 4
EPD Electromagnetic Flow Meter-5

LCM 128*64 pixel backlit type Tri-button operation Communication interface Accuracy RS-485 (Modbus) (Optional support for ZigBee Pro wireless transmission) ±0.5% of reading@1m/s(0.2% optional) Medium temperature Ambient temperature Fluidic conductivity Measuring scope Current output accuracy 0.1m/s ~ 10m/s 0.1% of Pulse Output Accuracy Temperature coefficient (100ppm/BC) Operating pressure Current output mode Analog output Maximum load of current output Alarming current Frequency output scope Pulse width Automatic (pulse width 50%) Pulse mode Time constant Control output (DO) Control input (DI)...

 Open the catalog to page 5
EPD Electromagnetic Flow Meter-6

MATERIAL SELECTION Electrode material Electrode material Anti-corrosion property Stainless steel (316L) It is applied in water, sewage and organic and non-organic corrosive medium. Hastelloy alloy It is resistant to the corrosion of the medium mixture of oxidizing acid such as Nitric acid, mixed acid or Sulfuric acid. Moreover, it is resistant to the corrosion of the oxidizing salt such as Fe2+、 Cu2+ or other substances containing oxidants such as the salt solution of hypochlorous acid above the ambient temperature and sea water. It is resistant to the corrosion of sea water, various oxides,...

 Open the catalog to page 6
EPD Electromagnetic Flow Meter-7

APPEARANCE AND DIMENSION AND FLANGE CONNECTION DIMENSION STANDARD TYPE Connection specification External diameter Lining material Nominal diameter(mm) Flange thickness Inclined angle of screw hole Diameter of screw hole Quantity of screw holes Height of sensor casing Total height Connection specification Nominal diameter(mm) Lining material External diameter Flange thickness Inclined angle of screw hole Diameter of screw hole Quantity of screw holes Height of sensor casing Total height Remarks: For DN15~DN80、DN350~DN500 , the lining protective ring is 2mm, so the total length of the flow meter...

 Open the catalog to page 7
EPD Electromagnetic Flow Meter-8

APPEARANCE AND DIMENSION AND FLANGE CONNECTION DIMENSION STANDARD TYPE Nominal diameter(mm) Lining material External diameter Flange thickness Inclined angle of screw hole Diameter of screw hole Quantity of screw holes Height of sensor casing Total height Remarks: For DN15~DN80、DN350~DN500 , the lining protective ring is 2mm, so the total length of the flow meter shall be increased by L+4mm. For DN100~DN300, the lining protective ring is 0.5mm, so the total length of the flow meter shall beincreased by L+1mm; total length (L) tolerance is ±3mm, total height (H2) tolerance is ±5m

 Open the catalog to page 8
EPD Electromagnetic Flow Meter-9

APPEARANCE AND DIMENSION AND FLANGE CONNECTION DIMENSION STANDARD TYPE Connection specification Nominal diameter(mm) Lining material External diameter Flange thickness Inclined angle of screw hole Diameter of screw hole Quantity of screw holes Height of sensor casing Total height Connection specification Nominal diameter(mm) Lining material External diameter Flange thickness Inclined angle of screw hole Diameter of screw hole Quantity of screw holes Height of sensor casing Total height Remarks: For DN15~DN80、DN350~DN500 , the lining protective ring is 2mm, so the total length of the flow meter...

 Open the catalog to page 9
EPD Electromagnetic Flow Meter-10

APPEARANCE AND DIMENSION AND FLANGE CONNECTION DIMENSION STANDARD TYPE DN15~80 Connection specification specification Connection Nominal diameter(mm) 15 Lining material Flange thickness Inclined angle of screw hole Diameter of screw hole Quantity of screw holes Height of sensor casing Total height Connection specification Nominal diameter(mm) Lining material Length Flange thickness Inclined angle of screw hole Diameter of screw hole Quantity of screw holes Height of sensor casing Total height Remarks: For DN15~DN80、DN350~DN500 , the lining protective ring is 2mm, so the total length of the flow...

 Open the catalog to page 10
EPD Electromagnetic Flow Meter-11

APPEARANCE AND DIMENSION AND FLANGE CONNECTION DIMENSION REMOTE TYPE External diameter Connection specification Nominal diameter(mm) Lining material Flange thickness Inclined angle of screw hole Diameter of screw hole Quantity of screw holes Height of sensor casing Diameter of screw hole Quantity of screw holes Height of sensor casing Nominal diameter(mm) PCD Flange thickness Inclined angle of screw hole Lining material External diameter Connection specification Remarks: *1: For DN15~DN80、DN350~DN500, the lining protective ring is 2mm, so the total length of the flow meter shall be increased...

 Open the catalog to page 11
EPD Electromagnetic Flow Meter-12

APPEARANCE AND DIMENSION AND FLANGE CONNECTION DIMENSION REMOTE TYPE Nominal diameter(mm) Lining material External diameter Flange thickness Inclined angle of screw hole Diameter of screw hole Quantity of screw holes Height of sensor casing *1: For DN15~DN80、DN350~DN500, the lining protective ring is 2mm, so the total length of the flow meter shall be increased by L+4mm. For DN100~DN300, the lining protective ring is 0.5mm, so the total length of the flow meter shall be increased by L+1mm; total length (L) tolerance is ±3mm, total height (H2) tolerance is ±5mm *2: To shows the weight of transducer...