Group: FINETEK
Catalog excerpts
Display Scaling Meter / Temperature Controller Innovation • Quality • Sharing
Open the catalog to page 1FEATURES Adapts microprocessor control circuit, modular design, advanced digital calibration, and switching power supply technology. Modulized design is a concept to adapt different analog input signals by means of changing different signal board (such as temperature, pressure, alternating voltage, electric current.). Also, optional output board could add the analog output signal (isolated). By using advanced digital calibration capability, its analog input/output could be accurate to +/- 1 bit. PB SERIES---BARGRAPH DISPLAY It is easy to tell the measuring, operator can tell measuring range...
Open the catalog to page 2NON-LINEAR TANK VOLUME CONVERSION FEATURE NON-LINEAR TANK VOLUME CONVERSION FEATURE PM/PB Series support volume adjustment function for non-linear tanks. By means of a 20-point look-up table, panel meter calculate tank volume according to the material level measured. Bundled with this package, a software is provided, user simply select tank type shown as below, and enter necessary dimension, tank volume and 20 control points will be calculated and reported. TANK TYPE: Length Width Length Height 2 Height 1
Open the catalog to page 3Microprocessor Bargraph Microprocessor DigitDisplay Panel Meter Display Panel Meter Appearance Display range Input signal "D C ro th Relay contact Power supply Analog output Communication port 4 Digits 7-Segment LED 101 LED Bargraph Display Totally 6 Set Points Refer to Input Signal Selection in Order Information (Page 6) Up to 4 Relays (as standard),SPST (N.O. or N.C. Jumper Selectable), 3A@250VAC/5A@30VDC 85~265VAC or 18~36VDC Refer to Input Signal Selection in Order Information (Page 8) Up to 2 Relays (as standard), SPST (N.O. or N.C. Jumper Selectable),...
Open the catalog to page 4FEATURES: -i 4 Digits LED Numeric Display ■ 101-segment LED Bargraph display -i Wide Range of User Definable Scaling Ratio ■ Modulized input signal boards available for different applications ■ Optional Output Boards with Isolated Analog Output & Relay Output -i 85V~265VAC or 18~36VDC Switching Power Supply -i Support volume adjustment function for non-linear tanks (optional) EXC 24V< GND < Volt Input Signal-Current Input Signal-Signal GND—
Open the catalog to page 5(Next page) PBX1 1 4 0 0 - B 6 □□ ® Power Supply A: 85~265Vac B: 18~36Vdc @© Single channel input — A1: 4~20mA DC with Exc 24V A2: 0~20mA DC with Exc 24V A3: 0~200mA DC with Exc 24V A4: 0~5V DC with Exc 24V A5: 0~10V DC with Exc 24V A6: 0-20V DC with Exc 24V A7: 0-200V DC with Exc 24V B1: 0~2mA AC RMS B2: 0~20mA AC RMS B3: 0~200mA AC RMS B4: 0~1A AC RMS B5: 0~5A AC RMS C1: 0~100mV AC RMS C2: 0~200mV AC RMS C3: 0~2V AC RMS C4: 0~20V AC RMS C5: 0~200V AC RMS C6: 0~600V AC RMS D1: 0~±2 mA DC with Exc 24 V D2: 0~±20 mA DC with Exc 24V D3: 0~±200 mA DC with Exc 24V D4: 0~±1Amp DC D5: 0~±5Amp...
Open the catalog to page 7ORDER INFORMATION Relay contact A: None C: 2 Relay E: 4 Relay G: 6 Relay Non-Linear function A: None B: Non - linear bucket conversion Analog output A: None B: 0~10V output C: 0/4~20mA output Communi-cation port
Open the catalog to page 8@© Single channel input- A1: 4~20mA DC with Exc 24V A2: 0~20mA DC with Exc 24V A3: 0~200mA DC with Exc 24V A4: 0~5V DC with Exc 24V A5: 0~10V DC with Exc 24V A6: 0-20V DC with Exc 24V A7: 0-200V DC with Exc 24V B1: 0~2mA AC RMS B2: 0~20mA AC RMS B3: 0~200mA AC RMS B4: 0~1A AC RMS B5: 0~5A AC RMS C1: 0~100mV AC RMS C2: 0~200mV AC RMS C3: 0~2V AC RMS C4: 0~20V AC RMS C5: 0~200V AC RMS C6: 0~600V AC RMS D1: 0~±2 mA DC with Exc 24V D2: 0~±20 mA DC with Exc 24V D3: 0~±200 mA DC with Exc 24V D4: 0~±1Amp DC D5: 0~±5Amp DC E1: 0~±20mV DC with Exc 24V E2: 0~±50mV DC with Exc 24V E3: 0~±100mV DC with...
Open the catalog to page 9ORDER INFORMATION Relay contact A: None C: 2 Relay E: 4 Relay Non-Linear function A: None B: Non - linear bucket conversion Analog output A: None B: 0~ 10V output C: 0/4~20mA output Communication port
Open the catalog to page 10This section will elaborate how to adapt to different input signals in the PB series panel meter, by using the correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup. Single Channel Signal Input Module: (For PB-1471) 03: 0~200mA DC with Excitation +24V EXC 24V Common 04: ± 5V DC with Excitation +24V EXC 24V Common CH1 Vinput DC V Common 05: ± 10V DC with Excitation +24V EXC 24V Common CH1 Vinput DC V Common eras Hist® EXC 24V Common c CH1 Vinput c Common c 07: ±200V DC...
Open the catalog to page 11PB AC SIGNAL INPUT MODULE This section will elaborate how to adapt to different input signals in the PB series panel meter, by using the correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup. Single Channel Signal Input Module: (For PB-1471) B1: 100mV AC Scaled RMS
Open the catalog to page 12PB DC SIGNAL INPUT MODULE This section will elaborate how to adapt to different input signals in the PB series panel meter, by using the correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup. Single Channel Signal Input Module: (For PB-1471) C1: 2mA DC with Excitation +24V EXC 24V Common C2: 20mA DC with Excitation +24V EXC 24V Common Input Common C3: 200mA DC with Excitation +24V EXC 24V Common Input Common D2: 50 mV DC with Excitation +24V EXC 24V Common Input Input...
Open the catalog to page 13PM DC SIGNAL INPUT MODULE This section will elaborate how to adapt to different input signals in the PM series panel meter, by using the correct jumper and using iSEL command. Panel meter series can accommodate 6 types of conventional input signals, 20mA, 200mA, 5V, 10V, 20V, 200V, please refer below for setup. Single Channel Signal Input Module: (For PM-1430) 01:4~20mA DC with Excitation +24V Common Input Common Input Common Input Common Input Common Input Common Input
Open the catalog to page 14All FineTek Co. catalogs and technical brochures
-
EFX By-Pass Level Transmitter
34 Pages
-
EPD Electromagnetic Flow Meter
28 Pages
-
Tuning Fork Level Switch
32 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Temperature Transmitter
5 Pages
-
Thermocouple
12 Pages
-
Vibrating point level switch
14 Pages
-
SA Capacitance Level Switch
18 Pages
-
SE Rotary Paddle Level Switch
15 Pages
-
EC Pressure Level Transmitter
12 Pages
-
SQ Pressure Switch
12 Pages
-
SD Optical Level Switch
2 Pages
-
FF Side Mounting Float Switch
15 Pages
-
FC/FD Mini Float Level Switch
28 Pages
-
RF-Admittance Level Switch
11 Pages
-
Optical Level Switch
13 Pages
-
Rotary Paddle Level Switch
15 Pages
-
Magnetic Float Level Transmitter
14 Pages
-
RF-Admittance Level Transmitter
15 Pages
-
Capacitance Level Switch
18 Pages
-
Vibrating Probe Level Switch
10 Pages
-
Pressure Level Transmitter
12 Pages
-
Magnetic Float Level Switch
24 Pages
-
EF By-Pass Level Transmitter
23 Pages
-
Air Hammer/Pneumatic Vibrator
16 Pages
-
Mini Float Level Switch
28 Pages
-
Pressure Switch
12 Pages
-
PID+Fuzzy Temperature Controller
23 Pages
-
Cable Float Level Switch
12 Pages
-
Side Mounting Float Switch
15 Pages