Capacitance Level Switch
Open the catalog to page 1PRODUCT INTRODUCTION The Fine-tek Capacitance Switch for liquids and solids can be used in mediums such as liquids, pastes, syrups, powders, granules, flakes and chips. It’s broad application and rugged build makes it a highly versatile across all industries. As Capacitance Level Switch has no moving parts inside the device, it will not be affected by friction. It is suitable for powder or liquid application easy to install. The customer can choose the types for his requirements. Capacitance switches rely on electrical capacitance theory (the ability of a medium to store electrical energy)....
Open the catalog to page 2STANDARD MODEL material PEEK Ambient temp. Operating temp. Operation pressure Probe material Insulated material Sensitivity range Housing spec. Supply voltage Delay time Power consumption Output rating
Open the catalog to page 3STANDARD TYPE 4- f19 material PVDF material UPE material CERAMIC [CORROSION-PROOF MODEL] [CORPOSION-PROOF MODEL] SA132 A/B/C SA130 A/B/C [SUPER HI-TEMP. MODEL ] SA128 A/B/C Ambient temp. Operating temp. Operation pressure Probe material Insulated material Sensitivity range Housing spec. Supply voltage Delay time Power consumption Output rating
Open the catalog to page 4STANDARD TYPE [REMOTE PROBE MODEL ] SA140 A/B/C Ambient temp. Operating temp. Operation pressure Probe material Insulated material Sensitivity range Housing spec. Supply voltage Delay time Power consumption Output rating
Open the catalog to page 5STANDARD MODEL [HI-TEMP. ANTI-STATIC MODEL] SA181 A/B/C Ambient temp. Operating temp. Operation pressure Probe material PTFE Coating Insulated material Sensitivity range Housing spec. Supply voltage Delay time Power consumption Output rating
Open the catalog to page 6EXPLOSION PROOF MODEL material PEEK Ambient temp. Operating temp. Operating pressure Probe material Insulated material Sensitivity range Weight Housing spec. Supply voltage Enclosure protection Power consumption Output contact rating 3 wire NPN output, max. load current 400mA 3 wire PNP output, max. load current 400mA 4 wire NPN/PNP output, max. 400mA/60Vdc
Open the catalog to page 7EXPLOSION PROOF MODEL material PVDF material UPE [CORROSION-PROOF MODEL] [CORROSION-PROOF MODEL] SA273 SA274 Ambient temp. Operating temp. Operating pressure Probe material Insulated material Connection Sensitivity range Weight Housing spec. Supply voltage Enclosure protection Power consumption Output contact rating 3 wire NPN output, max. load current 400mA 3 wire PNP output, max. load current 400mA 4 wire NPN/PNP output, max. 400mA/60Vdc
Open the catalog to page 8EXPLOSION PROOF MODEL [HI-TEMP ANTI-STATIC MODEL] SA277 Ambient temp. Operating temp. Operating pressure PTFE Coating Probe material Insulated material Sensitivity range Weight Housing spec. Supply voltage Enclosure protection Power consumption Output contact rating 3 wire NPN output, max. load current 400mA 3 wire PNP output, max. load current 400mA 4 wire NPN/PNP output, max. 400mA/60Vdc
Open the catalog to page 9INTRINSICALLY SAFE MODEL material PEEK Ambient temp. Operating temp. Operation pressure Probe material Insulated material Sensitivity range Housing spec. Supply voltage Enclosure protection Power consumption Output rating
Open the catalog to page 10INTRINSICALLY SAFE MODEL material PVDF material UPE [CORROSION-PROOF MODEL] [CORROSION-PROOF MODEL] SA373(WITH SA-75U) SA374(WITH SA-75U) Ambient temp. Operating temp. Operation pressure Probe material Insulated material Connection Sensitivity range Housing spec. Supply voltage Delay time Power consumption Output rating
Open the catalog to page 11INTRINSICALLY SAFE MODEL [HI-TEMP. ANSI-STATIC MODEL] SA377(WITH SA-75U) Ambient temp. Operating temp. Operation pressure material Insulated material Sensitivity range Housing spec. Supply voltage Delay time Power consumption Output rating
Open the catalog to page 12SA-75U INTRINSIC SAFE SIGNAL CONDITIONER SA-75U Zener barriers inside provide intrinsic safety to SA379 molel level switch. The unit works uses a current-limiting feature protecting the device from power surges, sparks and other electrical damage. 1. Supply voltage : 2. Power consumption : 2W 3. Input signal : 5. Short circuit current : 4 WIRING CONFIGURATION Wall (Non-hazardous area) Remote Control Room
Open the catalog to page 13QUICK CALIBRATION DELAY FUNCTION CALIBRATION 1.Turn the "SENSITIVITY" to the "H" position. 2.Place a flat screw driver in the "Coarse" coarse hole, turn clockwise until INDICATOR turns on. Check whether "Indicator" light is on or not by turning the "Sensitivity Adj" knob again. 3.If not, repeat procedure. The default setting is 0 second when material comes into contact with the probe (Indicator ON) For setting the delay function, turn the screw clockwise. The further clockwise, the longer the delay. The delay function is suitable for mediums with agitators, splashing or level turbulence in...
Open the catalog to page 14INSTALLATION NOTICE The insulation part should be mounted to protrude 30mm from the vessel wall. SA160 should be mounted as above. To prevent false readings,check the flow pattern ( angle a) of the material and place the probe in the appro-priate location. If the probe is mounted on the top, make sure the length of probe long enough to touch the highest level of medium. The SA160 MODEL is usually installed at the lower wall of the tank. For Non-Stationary or vibrating environment, a separate control unit such as the SA140 is suggested. It is suggested to install the probe away from the...
Open the catalog to page 15INSTALLATION NOTICE The probe should not be mounted underneath a liquid inlet, otherwise it will switch on erroneously. If two parallel probes are mounted, they must be installed separately at least 300 mm to minimize interference . If the tank equips with agitator, please use the time-delay type to prevent fault level detection. Mounting the probe at a 20B incline will optimize the results and increase sensitivity. It also won't be damaged by the inflowing material. Mounting the probe at top of tank can avoid material bridges from forming. It's helpful to record accurate measurements. The...
Open the catalog to page 16ORDER INFORMATION SA Model 119 --- Standard Type 129 --- Hi-temp. Type 139--- Corrosion Proof Type 140 --- Remote Probe Type 150 --- Wire Probe Type 160 --- Plate Type 189 --- Anti-Static Type 279 --- Explosion Proof Type 379 --- Explosion Proof Type Terminal Arrangement D---Must use with SA-75U A---110/220VAC E---DC24V, 3-wire NPN output (SA27X Only) B---DC24V, relay output C---DC24V, 3- wire NPNoutput F---DC24V, 4-wire PNP/NPN output(SA27X Only) SA999A Relay output Relay output Ex (ia) IIC Control unit output RELAY OUTPUT AC SUPPLY External power supply DC24V, 4-wire PNP/NPN output (SA27X...
Open the catalog to page 17All FineTek Co. catalogs and technical brochures
-
EFX By-Pass Level Transmitter
34 Pages
-
EPD Electromagnetic Flow Meter
28 Pages
-
Tuning Fork Level Switch
32 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Temperature Transmitter
5 Pages
-
Thermocouple
12 Pages
-
Vibrating point level switch
14 Pages
-
SA Capacitance Level Switch
18 Pages
-
SE Rotary Paddle Level Switch
15 Pages
-
EC Pressure Level Transmitter
12 Pages
-
SQ Pressure Switch
12 Pages
-
SD Optical Level Switch
2 Pages
-
FF Side Mounting Float Switch
15 Pages
-
FC/FD Mini Float Level Switch
28 Pages
-
RF-Admittance Level Switch
11 Pages
-
Optical Level Switch
13 Pages
-
Rotary Paddle Level Switch
15 Pages
-
Magnetic Float Level Transmitter
14 Pages
-
RF-Admittance Level Transmitter
15 Pages
-
Vibrating Probe Level Switch
10 Pages
-
Pressure Level Transmitter
12 Pages
-
Magnetic Float Level Switch
24 Pages
-
EF By-Pass Level Transmitter
23 Pages
-
Air Hammer/Pneumatic Vibrator
16 Pages
-
Mini Float Level Switch
28 Pages
-
Pressure Switch
12 Pages
-
PID+Fuzzy Temperature Controller
23 Pages
-
Cable Float Level Switch
12 Pages
-
Side Mounting Float Switch
15 Pages