Serie 40
20Pages

{{requestButtons}}

Catalog excerpts

Serie 40 - 1

40 SERIES PCB/Plug-in relays from 8 to 16 A Power relays 1 and 2 pole for direct PCB or socket mount Type 40.31 -- 1 CO 10 A (3.5 mm pin pitch) Type 40.51 -- 1 CO 10 A (5 mm pin pitch) Type 40.52 • DC coils (standard or sensitive) or AC coils • Cadmium-free contact material • 8 mm Creepage and Clearance, 6 kV (1.2/50µs) • 1 CO 10 A • 1 CO 10 A • 2 CO 8 A • 3.5 mm pin pitch • 5.0 mm pin pitch • 5.0 mm pin pitch • PCB or 95 Series socket mount • PCB or 95 Series socket mount • PCB or 95 Series socket mount between coil and contact • 95 series sockets for PCB or 35 mm rail mounting (EN 60715) with Screw, Screwless or Push-in terminals • Coil Indication and EMC suppression modules 99 series and Timer module 86.30 options • Environmental protection: RT II - flux proof (Standard) RT III - wash tight (Option) For UL ratings see: “General technical information” page V Copper side view Copper side view For outline drawing see page 10 Copper side view Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage Single phase motor rating (230 V AC) Minimum switching load Standard contact material Coil specification Nominal voltage (UN) V DC Rated power AC/DC/sens. DC Operating range Holding voltage Must drop-out voltage Mechanical life Electrical life at rated load AC1 Technical data Operate/release time Insulation between coil and contacts (1.2/50 µs) Dielectric strength between open contacts Ambient temperature range Environmental protection

Open the catalog to page 1
Serie 40 - 2

40 SERIES PCB/Plug-in relays from 8 to 16 A Power relays 1 and 2 pole for direct PCB or socket mount Type 40.61 A "1 CO 16 A (5.0 mm pin pitch) - DC coils (standard or sensitive) or AC coils Type 40.xx.6 - Bistable versions of the types 40.31,40.51, 40.52 and 40.61 - Bistable (single coil) DC or AC coils • Cadmium-free contact material available • 8 mm Creepage and Clearance, 6 kV (1.2/50ps) between coil and contact • 95 series sockets for PCB or 35 mm rail mounting (EN 60715) with Screw, Screwless or Push-in terminals • Coil Indication and EMC suppression modules 99 series and Timer module...

Open the catalog to page 2
Serie 40 - 3

40 SERIES PCB/Plug-in relays from 8 to 16 A Power relays 1 pole for direct PCB or socket mount • Pin length 3.5 mm for PCB mount • Pin length 5.3 mm for Plug-in mount • DC coils (650 mW or 500 mW) • Cadmium-free contact material available • 8 mm Creepage and Clearance, 6 kV (1.2/50µs) between coil and contact • Meets EN 60335-1 glow wire requirements • 95 series sockets for PCB or 35 mm rail mounting (EN 60715) with Screw, Screwless or Push-in terminals • Coil Indication and EMC suppression modules 99 series and Timer module 86.30 options • Environmental protection: RT II - flux proof...

Open the catalog to page 3
Serie 40 - 4

40 SERIES PCB/Plug-in relays from 8 to 16 A Type 40.11 - 1 CO 10 A - flat pack A • DC (sensitive) coils • Cadmium-free contact material available • 8 mm Creepage and Clearance, 6 kV (1.2/50ps) between coil and contact For UL ratings see: “General technical information" page V For outline drawing see page 10 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/ Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V A Minimum switching...

Open the catalog to page 4
Serie 40 - 5

40 SERIES PCB/Plug-in relays from 8 to 16 A Ordering information Example: 40 series PCB relay, 2 CO, 230 V AC coil. A: Contact material See table below B: Contact circuit 0 = CO (nPDT) 3 = NO (nPST) Series Type- 1 = PCB - 3.5 mm pinning, flat 3 = PCB/Plug-in - 3.5 mm pinning 5 = PCB/Plug-in - 5 mm pinning 6 = PCB/Plug-in - 5 mm pinning No. of poles- D: Special versions 0 = Standard 1 = Wash tight (RT III) 3 = High temperature (+125 °C) wash tight C: Options 0 = Pin length 5.3 mm (Plug-in relays) 2 = Pin length 3.5 mm (PCB relays) Coil version- 6 = AC/DC bistable 7 = Sensitive DC, 0.5 W 8 =...

Open the catalog to page 5
Serie 40 - 6

40 SERIES PCB/Plug-in relays from 8 to 16 A Technical data Insulation according to EN 61810-1

Open the catalog to page 6
Serie 40 - 7

40 SERIES PCB/Plug-in relays from 8 to 16 A Contact specification F 40 - Electrical life (AC) v contact current Types 40.31/51/61 F 40 - Electrical life (AC) v contact current Types 40.52 limit for 40.31/51 **Inductive load - AC15 Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 * limit for 40.31, see page 3 ** Inductive load - AC15 for 40.31/61, see page 3 Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 H 40 - Maximum DC1 breaking capacity 40.61 current limit 40.11/31/51 current limit 40.52 current limit F 40 - Electrical...

Open the catalog to page 7
Serie 40 - 8

40 SERIES PCB/Plug-in relays from 8 to 16 A Coil specifications DC coil data - 0.65 W standard (types 40.31/51/52/61) DC coil data - 0.5 W sensitive (types 40.31/51/52/61) Nominal voltage Un Nominal voltage Un DC coil data - 0.5 W sensitive (types 40.11)

Open the catalog to page 8
Serie 40 - 9

40 SERIES PCB/Plug-in relays from 8 to 16 A Contact specification R 40 - DC coil operating range v ambient temperature Standard coil R 40 - DC coil operating range v ambient temperature Sensitive coil, types 40.31/51/52/61 R 40 - DC coil operating range v ambient temperature Sensitive coil, type 40.11 R 40 - AC coil operating range v ambient temperature 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. Wiring diagram for 40 series bistable coil version AC...

Open the catalog to page 9
Serie 40 - 10

40 SERIES PCB/Plug-in relays from 8 to 16 A Outline drawings Type 40.31/51/52/61

Open the catalog to page 10
Serie 40 - 11

95 SERIES Socket overview for 40 series relays

Open the catalog to page 11
Serie 40 - 12

95 SERIES Socket and accessories for 40 series relays 95.P5 Approvals (according to type): cc © cw; RINA Push-in terminals socket panel or 35 mm rail mount * For currents > 10 A, contact terminals must be connected in parallel (21 with 11,24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. 2-way jumper link for 95.P3 and 95.P5 sockets

Open the catalog to page 12

All FINDER S.p.A. con unico socio catalogs and technical brochures

  1. CATALOGUE

    900 Pages

  2. 30 SERIES

    6 Pages

  3. Series 22

    5 Pages

  4. 66 Series

    10 Pages

  5. Brochure 58

    8 Pages

  6. General catalog

    587 Pages

  7. Série 43

    4 Pages

  8. Series 20

    4 Pages

  9. Série 13

    2 Pages

  10. 32 SERIES

    4 Pages

  11. Series 77

    2 Pages

  12. 50 series

    4 Pages

  13. 48 Series

    10 Pages

  14. 46 Series

    10 Pages