68 Series - High Power relay 100 A
6Pages

{{requestButtons}}

Catalog excerpts

68 Series - High Power relay 100 A - 1

High Power relay 100 A Power generators Back-up generators Pump control Disabled lift Charging Stations

Open the catalog to page 1
68 Series - High Power relay 100 A - 2

FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.

Open the catalog to page 2
68 Series - High Power relay 100 A - 3

68 SERIES High Power relay 100 A Printed circuit mount - 3.6 mm contact gap Relay for applications with high power Type 68.22-4300 - 2 NO • DC coils, with only 700 mW holding power • Reinforced insulation between coil and contacts • Suitable for use at ambient temperatures up • 2 NO • Contact gap 3.6 mm • PCB mount • Meets the EN 60335-1 requirements of resistance to heat and fire (GWIT 775 °C and GWFI 850 °C) • Cadmium free contact materials For outline drawing see page 6 Copper side view Contact specification Contact configuration Rated current/ Maximum peak current (for 1 ms) Rated...

Open the catalog to page 3
68 Series - High Power relay 100 A - 4

68 SERIES High Power relay 100 A Ordering information Example: 68 series, power relay for printed circuit, 2 NO contacts, 12 V DC coil. A: Contact material 4 = tandard AgSnO2 S Type 2 = -phase PCB terminals, 3 1.5 mm gap between PCB and relay base No. of poles 2 = pole 2 D: Special versions 0 = tandard S B: Contact circuit 3 = NO, ≥ 3.6 mm contact gap Coil version 9= C D Coil voltage See coil specifications Technical data Insulation according to EN 61810-1 Nominal voltage of supply system Rated insulation voltage Pollution degree Insulation between coil and contact set Type of Insulation...

Open the catalog to page 4
68 Series - High Power relay 100 A - 5

68 SERIES High Power relay 100 A Contact specification F 68 - Electrical life v contact current NOTE: for ambient temperatures between 70 and 85 ° C, the electrical life is reduced by 30% H 68 - Maximum DC breaking capacity When switching a resistive (DC1) or inductive (DC13) load having voltage and current values under the corresponding curve, an electrical life of > 30000 cycles can be expected. NOTE: The heating and electrical endurance tests have been performed on relays soldered on PC boards having the following characteristics: double side, copper thickness >105 μm, contact tracks...

Open the catalog to page 5
68 Series - High Power relay 100 A - 6

68 SERIES High Power relay 100 A Coil specifications DC coil data Nominal voltage Coil code Holding voltage Rated coil consumption I at UN R 68-1 - perating range v ambient temperature, O with standard (continuous) coil energization (–40…+70)°C 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. R 68-2 - perating range v ambient temperature, O in energy saving mode (–40…+85)°C Energy saving mode In some applications, such as photovoltaic inverters, it may be necessary to minimize the overall relay power dissipation and to permit use at higher ambient...

Open the catalog to page 6

All FINDER S.p.A. con unico socio catalogs and technical brochures

  1. CATALOGUE

    900 Pages

  2. 30 SERIES

    6 Pages

  3. Series 22

    5 Pages

  4. 66 Series

    10 Pages

  5. Brochure 58

    8 Pages

  6. General catalog

    587 Pages

  7. Série 43

    4 Pages

  8. Serie 40

    20 Pages

  9. Series 20

    4 Pages

  10. Série 13

    2 Pages

  11. 32 SERIES

    4 Pages

  12. Series 77

    2 Pages

  13. 50 series

    4 Pages

  14. 48 Series

    10 Pages

  15. 46 Series

    10 Pages