Catalog excerpts

46 SERIES Miniature industrial relays 8 to16 A 1 & 2 CO industrial style power relays For socket mount or direct connection via Faston connectors Type 46.52 - 2 CO 8 A Type 46.61 - 1 CO 16 A • AC coils & DC coils • Available with: lockable test button, mechanical indicator & LED indicator • 8 mm, 6 kV (1.2/50 ps) isolation, coil-contacts • Cadmium free contacts • 97 series 35 mm rail (EN 60715) Screw, Screwless or Push-in terminals, and PCB mount sockets • Coil Indication and EMC suppression modules 99 series and Timer module 86.30 options • Optional alternative mounting adaptors • European Patent -in/Solder terminals For UL ratings see: “General technical information" page V Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/ Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V A Minimum switching load mW (V/mA) Standard contact material Coil specification Nominal voltage (UN) V AC (50/60 Hz) Operating range AC Must drop-out voltage AC/DC Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 ps) kV Dielectric strength between open contacts V AC Ambient temperature range °C Environmental protection Approvals (according to type) With the AgSnO2 material the maximum peak current is 80 A - 5 ms on normally open contact.
Open the catalog to page 1
46 SERIES Miniature industrial relays 8 to16 A Ordering information Example: 46 series Miniature industrial relay, 1 CO, 24 V DC coil, lockable test button and mechanical indicator. A A B c d 5 = Spade/blade solder terminal (2.5 x 0.5)mm 6 = Spade/blade terminal Faston 187 (4.8 x 0.5)mm No. of poles — 1 = 1 pole, 16 A 2 = 2 poles, 8 A Coil voltage See coil specifications Descriptions: Options A: Contact material 0 = AgNi 4 = AgSnO2 (46.61 only) 5 = AgNi + Au B: Contact circuit 0 = CO (nPDT) D: Special versions 0 = Standard C: Options 2 = Mechanical indicator 4 = Lockable test button...
Open the catalog to page 2
46 SERIES Miniature industrial relays 8 to16 ATechnical data F 46 - Electrical life (AC) v contact current Type 46.61 • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of > 100 • 103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased.
Open the catalog to page 3
46 SERIES Miniature industrial relays 8 to16 A finder Coil specificationsDC coil data Nominal voltage Un R 46 - DC coil operating range v ambient temperature R 46 - AC coil operating range v ambient temperature 2 - Min. pick-up voltage with coil at ambient temperature. 2 - Min. pick-up voltage with coil at ambient temperature.
Open the catalog to page 4
97 SERIES Sockets and accessories for 46 series relays Accessories Flange mount adaptor for relays types 46.52 and 46.61 35 mm rail adaptor for relays types 46.52 and 46.61 | 046.07 Sheet of marker tags (CEMBRE Thermal transfer printers) for relays types 46.52 and 46.61 (48 tags), 6 x 12 mm
Open the catalog to page 5
97 SERIES Sockets and accessories for 46 series relays Approvals (according to type): CCtEHHB © Mus Push-in terminal socket panel or 35 mm rail (EN 60715) mount 8-way jumper link for 97.P1 and 97.P2 sockets 2-way jumper link for 97.P1 and 97.P2 sockets
Open the catalog to page 6
97 SERIES Sockets and accessories for 46 series relays 2-way jumper link for 97.P1 and 97.P2 sockets Marker tag holder for 95.P3 and 95.P5 sockets 86 series timer modules Approvals (according to type): C€ EHE <£ <*1 US 99.1 Approvals (according to type): ER[ C- cWus DC Modules with non-standard polarity (+A2) on request.
Open the catalog to page 7
97 SERIES Sockets and accessories for 46 series relays Approvals (according to type): C€@EH[<E © cTO®us Screw terminal socket panel or 35 mm rail (EN 60715) mount L 97 - Rated current v ambient temperature (for 46.61 relay/97.01 socket combination)
Open the catalog to page 8
97 SERIES Sockets and accessories for 46 series relays Approvals (according to type): Screwless terminal socket panel or 35 mm rail (EN 60715) mount 86 series timer modules Approvals (according to type): C€ EHE C c*\ US EHE <C c^us DC Modules with non-standard polarity (+A2) on request. 99.02 coil indication and EMC suppression modules for 97.51 and 97.52 sockets
Open the catalog to page 9
97 SERIES Sockets and accessories for 46 series relays Approvals (according to type): fn[ (£ @ w„, L 97 - Rated current v ambient temperature Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: SM Metal retaining clip SL Plastic retaining clip
Open the catalog to page 10All FINDER S.p.A. con unico socio catalogs and technical brochures
-
CATALOGUE
900 Pages
-
RAILWAY APPLICATIONS
8 Pages
-
MARINE APPLICATIONS
7 Pages
-
SELECTION GUIDE
16 Pages
-
7M Smart energy meters
14 Pages
-
YESLY 13 SERIES
4 Pages
-
30 SERIES
6 Pages
-
Product News 70
2 Pages
-
Product News SAFE
2 Pages
-
Product News 7S
2 Pages
-
Series 22
5 Pages
-
Product News 39
5 Pages
-
66 Series
10 Pages
-
Brochure 58
8 Pages
-
Product News ATEXUSA
2 Pages
-
Product News ATEX
2 Pages
-
General catalog
587 Pages
-
Série 43
4 Pages
-
Serie 40
20 Pages
-
Series 20
4 Pages
-
Série 13
2 Pages
-
32 SERIES
4 Pages
-
Series 77
2 Pages
-
50 series
4 Pages
-
48 Series
10 Pages