Catalog excerpts
46 SERIES Miniature industrial relays 8 to16 A 1 & 2 CO industrial style power relays For socket mount or direct connection via Faston connectors Type 46.52 - 2 CO 8 A Type 46.61 - 1 CO 16 A • AC coils & DC coils • Available with: lockable test button, mechanical indicator & LED indicator • 8 mm, 6 kV (1.2/50 ps) isolation, coil-contacts • Cadmium free contacts • 97 series 35 mm rail (EN 60715) Screw, Screwless or Push-in terminals, and PCB mount sockets • Coil Indication and EMC suppression modules 99 series and Timer module 86.30 options • Optional alternative mounting adaptors • European Patent -in/Solder terminals For UL ratings see: “General technical information" page V Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/ Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V A Minimum switching load mW (V/mA) Standard contact material Coil specification Nominal voltage (UN) V AC (50/60 Hz) Operating range AC Must drop-out voltage AC/DC Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 ps) kV Dielectric strength between open contacts V AC Ambient temperature range °C Environmental protection Approvals (according to type) With the AgSnO2 material the maximum peak current is 80 A - 5 ms on normally open contact.
Open the catalog to page 146 SERIES Miniature industrial relays 8 to16 A Ordering information Example: 46 series Miniature industrial relay, 1 CO, 24 V DC coil, lockable test button and mechanical indicator. A A B c d 5 = Spade/blade solder terminal (2.5 x 0.5)mm 6 = Spade/blade terminal Faston 187 (4.8 x 0.5)mm No. of poles — 1 = 1 pole, 16 A 2 = 2 poles, 8 A Coil voltage See coil specifications Descriptions: Options A: Contact material 0 = AgNi 4 = AgSnO2 (46.61 only) 5 = AgNi + Au B: Contact circuit 0 = CO (nPDT) D: Special versions 0 = Standard C: Options 2 = Mechanical indicator 4 = Lockable test button...
Open the catalog to page 246 SERIES Miniature industrial relays 8 to16 ATechnical data F 46 - Electrical life (AC) v contact current Type 46.61 • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of > 100 • 103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased.
Open the catalog to page 346 SERIES Miniature industrial relays 8 to16 A finder Coil specificationsDC coil data Nominal voltage Un R 46 - DC coil operating range v ambient temperature R 46 - AC coil operating range v ambient temperature 2 - Min. pick-up voltage with coil at ambient temperature. 2 - Min. pick-up voltage with coil at ambient temperature.
Open the catalog to page 497 SERIES Sockets and accessories for 46 series relays Accessories Flange mount adaptor for relays types 46.52 and 46.61 35 mm rail adaptor for relays types 46.52 and 46.61 | 046.07 Sheet of marker tags (CEMBRE Thermal transfer printers) for relays types 46.52 and 46.61 (48 tags), 6 x 12 mm
Open the catalog to page 597 SERIES Sockets and accessories for 46 series relays Approvals (according to type): CCtEHHB © Mus Push-in terminal socket panel or 35 mm rail (EN 60715) mount 8-way jumper link for 97.P1 and 97.P2 sockets 2-way jumper link for 97.P1 and 97.P2 sockets
Open the catalog to page 697 SERIES Sockets and accessories for 46 series relays 2-way jumper link for 97.P1 and 97.P2 sockets Marker tag holder for 95.P3 and 95.P5 sockets 86 series timer modules Approvals (according to type): C€ EHE <£ <*1 US 99.1 Approvals (according to type): ER[ C- cWus DC Modules with non-standard polarity (+A2) on request.
Open the catalog to page 797 SERIES Sockets and accessories for 46 series relays Approvals (according to type): C€@EH[<E © cTO®us Screw terminal socket panel or 35 mm rail (EN 60715) mount L 97 - Rated current v ambient temperature (for 46.61 relay/97.01 socket combination)
Open the catalog to page 897 SERIES Sockets and accessories for 46 series relays Approvals (according to type): Screwless terminal socket panel or 35 mm rail (EN 60715) mount 86 series timer modules Approvals (according to type): C€ EHE C c*\ US EHE <C c^us DC Modules with non-standard polarity (+A2) on request. 99.02 coil indication and EMC suppression modules for 97.51 and 97.52 sockets
Open the catalog to page 997 SERIES Sockets and accessories for 46 series relays Approvals (according to type): fn[ (£ @ w„, L 97 - Rated current v ambient temperature Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: SM Metal retaining clip SL Plastic retaining clip
Open the catalog to page 10All FINDER S.p.A. con unico socio catalogs and technical brochures
-
CATALOGUE
900 Pages
-
RAILWAY APPLICATIONS
8 Pages
-
MARINE APPLICATIONS
7 Pages
-
SELECTION GUIDE
16 Pages
-
7M Smart energy meters
14 Pages
-
YESLY 13 SERIES
4 Pages
-
30 SERIES
6 Pages
-
Product News 70
2 Pages
-
Product News SAFE
2 Pages
-
Product News 7S
2 Pages
-
Series 22
5 Pages
-
Product News 39
5 Pages
-
66 Series
10 Pages
-
Brochure 58
8 Pages
-
Product News ATEXUSA
2 Pages
-
Product News ATEX
2 Pages
-
General catalog
587 Pages
-
Série 43
4 Pages
-
Serie 40
20 Pages
-
Series 20
4 Pages
-
Série 13
2 Pages
-
32 SERIES
4 Pages
-
Series 77
2 Pages
-
50 series
4 Pages
-
48 Series
10 Pages