The RXO and RXV gear units conform to the Renard Ra20 series for dimensions and transmission ratios, enabling versatile mounting and applications. The casing is split with bolted covers for maintenance. Gears are helical spur and Gleason bevel types, case hardened and ground for precision, low noise, and efficiency (0.91–0.95). Materials comply with UNI 7846-78 standards. Load capacity follows ISO 6336, optionally verified by AGMA 2001-C95. Shafts use high-grade steels with high safety factors and international standard keyways. Bearings are tapered or self-aligning rollers sized for longevity. Casings up to size 820 are cast iron; larger sizes use welded Fe430 steel for rigidity.
Noise is measured at 1 m distance at 1450 rpm input speed with ±3 dB(A) tolerance. Fan cooling adds +2 dB(A) per fan. Adjustments for other speeds are provided. Reduced noise versions are available. SPL varies by size and gear ratio, detailed in tables.
Selection depends on the service factor (Fs), which accounts for operating conditions, daily hours, starts per hour, and reliability. Fs can be assigned or calculated as Fs = fs × fv × fGa, where fs is duration factor, fv is start factor, and fGa is reliability factor. Catalog ratings assume Fs=1; for speed multipliers, multiply Fs by 1.1. Tables provide Fs values by prime mover type and load shock severity.
Applications include agitators, alimentary machinery, winches, paper mills, chemical industry, compressors, dredges, building machinery, elevators, cranes, wood processing, machine tools, mixers, earth moving machinery, pumps, conveyors, water treatment, and fans. Each sector details equipment types and load characteristics.
Reliability factor (fGa) ranges from 1 (normal) to 1.4 (high reliability) depending on maintenance difficulty and safety needs. Service factor (fS) adjusts for frequent starts or high starting torque via correction factor (fV) based on starts per hour and application type (U, M, S).
Input speed correction factor (fN) adjusts power and torque ratings for speeds above 1450 min⁻¹. Tables specify values by speed and gear ratio.
For continuous or heavy intermittent loads in high-temperature or poor cooling environments, verify that nominal thermal power (PtN) multiplied by correction factors (fm, fa, fd, fp, ff) exceeds absorbed power. If not, upgrade cooling with heat exchangers. Calculate additional thermal power (Pta) and verify with water (fw) and air (fc) temperature factors.
Maximum input speeds depend on gearbox model and lubrication method (splash or forced). Tables specify limits; some values available on request.
Correction factors defined as:
Tables provide values for these factors based on conditions.
Graphical codes and compatibility tables define shaft arrangements (e.g., A, B, ABU, C1, C2), input/output configurations, fan options, and backstops, ensuring mechanical and thermal integration.
Geared motor applications require specifying motor designation per the "Electronic Line" catalog, matching motor shaft arrangements, reduction ratios, and mounting positions with gear units.
Housing materials include steel, spheroidal cast iron, and engineering cast iron, depending on size and type. Options include reinforced output bearings for heavy-duty use, flange bearings, and special output shaft ends.
Various flange bearing arrangements at output shaft ends include hollow shafts and shrink disc options, mainly for RXO2 and RXO3 models. Configurations include right/left hollow shaft with flange bearing (SCS), flange bearing with shrink disc (SUS), and combinations with shrink disc provisions (SBD, SBS). Additional options available on request.
Oils are categorized as mineral, PAO synthetic, and polyglycol (PG) synthetic. Selection depends on load, duty, and temperature:
Food-grade oils are available for food industry applications.
Viscosity grades (ISO VG) recommended based on input speed and power, with forced lubrication preferred for higher power/lower speed. Viscosity ranges from ISO VG 68 to 680 depending on conditions.
Synthetic oils allow longer intervals than mineral oils. Typical operating temperatures considered are 65°C, 80°C, and 90°C.
Comparative tables list products from major manufacturers (AGIP, ARAL, BP, CASTROL, CHEVRON, ESSO, KLÜBER, MOBIL, OPTIMOL, Q8, SHELL, TEXACO, TOTAL, TRIBOL), including food-grade synthetics.
Lubricant volumes vary by gear unit size (802 to 830), series (RXO1, RXO2, RXO3, RXV1, RXV2, RXV3), and mounting position (M1 to M6), ranging from ~2.5 L to over 950 L. Users must follow gear unit level marks and agree on any plug arrangement deviations.
Forced lubrication of upper bearings is linked to forced gear lubrication when required, ensuring adequate lubrication under heavy loads.
Multiple mounting positions (M1 to M6) are defined with graphical representations; alternatives detailed elsewhere.
Correction coefficients (A, B, C) adjust permissible radial loads (Fr1 input shaft, Fr2 output shaft) based on load application distance from shaft shoulder. Formulas calculate adjusted radial loads (Fr1', Fr2'). Maximum radial loads are rated at 0.5 shaft projection distance with Fs=1.
Procedures verify radial and axial loads on shafts due to prime movers or driven machines. Approximate formulas estimate radial loads for friction wheels, belts, gears, chains. Winch drum rope winding recommendations minimize load severity.
Technical support is advised for complex verifications.
Detailed tables provide gear ratios, output speeds, rated power (kW), torque (kNm), permissible radial loads (kN) at input speeds 1450, 1000, 500 min⁻¹, and thermal power limits without cooling. Data supports selection based on operational needs.
Data includes power ratings, torque, speeds, and thermal power limits without cooling. RXO2 units range ~20–79 kW power and 102–445 kW thermal limits; RXO3 units range ~13–72 kW power and 14–77 kW thermal limits. Hollow output shafts unavailable for some ratios (marked *).
Thermal power ratings up to ~20 kW without cooling. Gear ratios range from ~1 to over 600. Nominal torque up to several hundred kNm. IEC motor compatibility covers frame sizes 71 to 355. Moments of inertia range from 0.0001 to >2.6 kg·m², critical for dynamic design.
Detailed shaft dimensions with ISO tolerance classes (h11, H7, j6, k6, m6) and keyway sizes are provided. IEC standard shaft diameters from 28 mm to 180 mm and mounting bolt sizes (M8 to M20) ensure compatibility. Weights range from ~80 kg to over 13,500 kg depending on size.
This document is a comprehensive technical reference for RXO and RXV series gear units, covering construction, performance, selection criteria, lubrication, thermal management, shaft arrangements, and detailed dimensional data to support engineering design and application.
Caratteristiche costruttive Construction features Livelli di pressione sonora SPL [dB(A)] Mean sound pressure levels SPL [dB(A)] Gear unit selection Verifica carichi radiali e assiali Overhung and thrust load verification Überprüfung der Radial- und Axialkräfte RXP1 gear unit ratings RXP2 gear unit ratings RXP3 gear unit ratings Motori applicabili Compatible motors Applizierbare Motoren Momenti d'inerzia Applizierbare Motoren 1.0 RIDUTTORI - MOTORIDUTTORI ORTOGONALI HELICAL BEVELGEARBOXES AND GEARED MOTORS KEGELRADGETRIEBE - KEGELRADGETRIEBEMOTOREN
Open the catalog to page 1General description Le dimensioni dei nostri riduttori e i rapporti di trasmissione seguono la serie dei numeri normali (serie di RENARD) Ra 20 UNI 2016. 68. I particolari accorgimenti adottati nella costruzione della carcassa esterna conferiscono ai nostri riduttori un'ampia versatilità di montaggio. Gear unit dimensions and transmission ratios follow a geometric progression based on the Ra20 series of preferred (or Renard) numbers in accordance with UNI 2016.68. The casing incorporates special design features to provide the utmost mounting versatility. La grande scelta disponibile del tipo...
Open the catalog to page 2Tutti i cuscinetti sono del tipo a rulli conici o a rulli orientabili, di elevata qualità e dimensionati per garantire una lunga durata se lubrificati con il tipo di lubrificante previsto a catalogo. All bearings are high quality taper or self-aligning roller bearings suitably sized to ensure long service life provided the approved lubricants indicated in this catalogue are used. Bei allen Lagern handelt es sich um hochqualitative Kegelrollenlager mit orientierungsfähigen Rollen und in Maßen, die so ausgelegt sind, dass sie bei Einsatz der gemäß Katalogangaben vorgesehenen Schmiermittel eine...
Open the catalog to page 31.3 Gear unit selection Il fattore di Servizio Fs dipende: Service factor Fs is determined on the basis of: a) operating conditions of application b) operation per day (h/d) c) starts and stops per hour d) desired reliability or safety factor. Der Betriebsfaktor Fs hängt von folgenden Kriterien ab: a) Einsatzbedingungen b) Betriebsdauer h/d c) Anläufe / Stunden d) Zuverlässigkeitsgrad oder gewünschter Sicherheitsbereich. Where service conditions allow it, the recommended service factor for a specific application may be u sed directly, otherwise the service factor must be calculated and the following...
Open the catalog to page 4Application classification SETTORE DI APPLICAZIONE AGITATORI Con densità uniforme Con densità non uniforme ALIMENTARE Maceratori, bollitori, coclee Trituratrici, sbucciatrici, scatolatrici ARGANI Sollevamento Trascinamento Bobinatori CARTARIO Avvolgitori, essiccatrici, pressatrici, Mescolatrici, estrusori, addensatrici Tagliatrici, lucidatrici CHIMICO Estrusori, stampatrici Importatrici COMPRESSORI Centrifughi Rotativi Assiali DRAGHE Trasportatori Estrattrici, teste fresatrici EDILIZIA Betoniere, coclee Frantoi, dosatrici Frantumatrici ELEVATORI A nastro, scale mobili A tazza, montacarichi, skip...
Open the catalog to page 5Duty cycle factor - fV Fattore correttivo del fattore di servizio Fs, per tenere conto degli avviamenti/ora. Il fattore di servizio Fs deve aumentare in caso di avviamenti frequenti con coppia di spunto notevolmente maggiore di quella di regime tenendo conto degli avviamenti per ora secondo la seguente tabella. This correction factor is used to adjust service Fs to reflect the number of starts per hour. Where an application involves frequent starts at a starting torque significantly greater than running torque, service factor fs must be adjusted to account for the number of starts per hour using...
Open the catalog to page 61)Compatibilità dimensionale con ingombri disponibili (es diametro del tamburo) e delle estremità d'albero con giunti,dischi o pulegge. 1) Ensure that dimensions are compatible with space constraints (for instance, drum diameter) and shaft ends are compatible with any couplings, discs or pulleys to be used. 1) Kompatibilität der Abmessungen mit verfügbaren Maßen (z.B. Trommeldurchmesser) und der Wellenenden mit den Kupplungen, Scheiben oder Riemenscheiben. 2) Compatibilità del rapporto selezionato con l'esecuzione albero cavo. 2) Ensure that selected ratio is available for the hollow shaft configuration....
Open the catalog to page 76) Verifica Posizione di montaggio 6) Check mounting position 7) Adeguatezza della potenza termica del riduttore: Nel caso di solo riduttore in servizio continuo o intermittente gravoso in ambienti a temperatura elevata e/o con difficoltà di scambio termico (es. acciaierie) è necessario verificare che la potenza termica nominale corretta dai fattori sia superiore alla potenza assorbita come evidenziato nella seguente equazione: 7) Ensure gear unit thermal power is suitable for the application: If a gear unit is to be used in continuous or intermittent duty in environments where high temperatures...
Open the catalog to page 8fm.: fattore correttivo per la posizione di montaggio , velocità e rapporto. (fm=1 nel caso in cui n1 richieda la lubrificazione forzata) (fm=1nel caso in cui n1= 0-749 min-1) size fm.: Korrekturfaktor für Einbaulage, Drehzahl und Übersetzungsverhältnis. (fm=1 falls n1 eine Zwangsschmierung erfordert) (fm=1 bei n1= 0-749 min-1) fm.: correction factor accounting for mounting position, speed and ratio. (fm=1 if n1 requires forced lubrication) N.B. I valori di n1max sono riportati al punto 5 (Verifiche). NOTE n1max values are listed at point 5 (Verification). Fattore correttivo dell'altitudine Altitude...
Open the catalog to page 9fp Fattore correttivo della temperatura ambiente. Ambient temperature factor. Temperatura ambiente Ambient temperature Umgebungstemperatur ff Il fattore correttivo ff della potenza termica che tiene conto dell'effetto refrigerante della ventola assume in accordo con le norme AGMA 6010.E88 i valori riportati nella tabella 8. L'impiego è limitato alle velocità maggiori o uguali a 700 min-1. Cooling fan factors ff reported in table 8 are in accordance with AGMA 6010. E88 and can be used directly to adjust thermal power to reflect the use of a cooling fan. These factors must only be used for speeds...