Catalog excerpts
HYDRAULIC FILTRATION F420-D1 series In line high pressure filters Technical Information Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T 3.10.5.1) Test 600 bar (8700 psi) (acc. to NFPA T 3.10.5.1) Burst 1260 bar (18300 psi) (acc. to NFPA T 3.10.5.1) Connection Ports: 1/2”÷1 1/2” BSP (other thread options on request) 3/4”÷1 1/2” SAE J518-6000 Materials: Head: Bowl: Seal: cast iron extruded steel Buna-N (FKM on request) By-pass: No by-pass or 6 bar (90 psi) setting Filter Media: Microglass fiber Differential collapse pressure: 21 bar (300 psi) or 210 bar (3000 psi) (acc. to ISO 2941) The Filtrec elements are tested also according to ISO 2942 and ISO 23181 Working temperature: -25°C +120°C (-13°F +248°F) Fluid compatibility (acc. to ISO 2943): Full with HH-HL-HM-HV (acc. to ISO 6743/4). For use with other fluid applications please contact Filtrec Customer Service (info@filtrec.it).
Open the catalog to page 1Ordering information MEDIA no element microglass fiber ß4,5 µm ( ) >1000 microglass fiber ß7 µm ( ) >1000 microglass fiber ß12 µm ( ) >1000 microglass fiber ß18 µm ( ) >1000 microglass fiber ß27 µm ( ) >1000 cellulose ß10 µm ( ) >2 cellulose ß20 µm ( ) >2 C Filter assembly Filter element NOMINAL SIZE ELEMENT COLLAPSE INDICATOR PORT OPTION recommended with no by-pass option. For different thread options, please check availability with Filtrec Customer Service. INDICATOR PORT OPTION indicator port, plugged INDICATOR TO BE USED WITH NO BY-PASS OPTION ONLY no indicator differential visual 5...
Open the catalog to page 2Overall dimensions Identification label Identification label Indicator port Indicator port Indicator port Indicator port A 1/2" BSP 3/4” BSP 3/4" BSP - flange 1" BSP - flange 1" BSP 1"1/4 BSP - flange 1"1/2 BSP - flange For alternative version, types and dimensions, see 5 pages later
Open the catalog to page 3Pressure drop diagrams The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow rate. This ideally should not exceed 1,0 bar (14,5 psi) and should never exceed 1/3 of the set value of the by-pass valve. Housing F420-D11... PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. Flow rate (l/min) Element D110-..-B Flow rate (gpm) The Pressure Drop through the filter element is related both to the internal diameter of the filter...
Open the catalog to page 4Pressure drop diagrams Housing F420-D12/D13... PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. Flow rate (l/min) The Pressure Drop through the filter element is related both to the internal diameter of the filter element and to the filter media; this value is effected by the oil viscosity in a roughly proportional way: e.g. when the Dp value from the curve is 0,2 bar and a 46 cSt oil is used, the corresponding value is 0,31 (=0,2 : 30 x 46) bar. PRESSURE DROP THROUGH THE CLEAN FILTER...
Open the catalog to page 5Pressure drop diagrams Housing F420-D14/D15... PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. Element D140-..-B Flow rate (gpm) Flow rate (l/min) Flow rate (l/min) Flow rate (l/min) Flow rate (l/min) Flow rate (l/min) Flow rate (l/min) Flow rate (l/min) The Pressure Drop through the filter element is related both to the internal diameter of the filter element and to the filter media; this value is effected by the oil viscosity in a roughly proportional way: e.g. when the Dp value from...
Open the catalog to page 6Pressure drop diagrams Element D143-..-A Flow rate (l/min) Flow rate (l/min) Flow rate (l/min) Flow rate (l/min) PRESSURE DROP THROUGH THE BY-PASS VALVE The by-pass valve is a safety device to prevent element collapse in case of differential pressure peaks due to flow peaks, cold start conditions or when the clogged element is not replaced in a timely manor. Flow rate (l/min) Flow rate (l/min) Flow rate (l/min) The above diagrams have been obtained at the FILTREC laboratory, according to the ISO 3968 specification, with mineral oil having 30 cSt viscosity and 0,86 Kg/dm3 density. In case of...
Open the catalog to page 7Filter Elements The F420 series is usually equipped with filter elements according to a widely accepted (US based) industry standard, having the dimensions listed here below. Alternative version The F420 series can be optionally equipped with filter elements according to a different standard (European based), having the dimensions listed here below. Their performances are corresponding to the standard version as indicated in the table, where you can see also the different filter housing lengths if applicable. Housing dimensions except *H1 see see see see see see see
Open the catalog to page 8Clogging indicator The Pressure Drop (Dp) through the filter increases during the system operation due to the contaminant retained by the filter element. The filter element must be replaced when the indicator shows an alarm and before the Dp reaches the by-pass value setting. N.B. in cold start conditions a false alarm can be caused by higher oil viscosity due to low temperature; the indicator alarm must be considered at normal working temperature only. The differential clogging indicator registers the pressure upstream and downstream the filter element and activates a signal when the...
Open the catalog to page 9User Tips FIXING HOLES T IDENTIFICATION LABEL INDICATOR PORT: Visual Electric FILTER ELEMENT FILTER BOWL SPARE SEAL KIT PART NUMBER NBR FKM F420-D1-10 06.021.00090 06.021.00135 F420-D1-20/30 06.021.00131 06.021.00136 F420-D1-40/50 06.021.00095 06.021.00137 BOWL TIGHTENING TORQUE F420-D1-10 65 Nm F420-D1-20/30 75 Nm F420-D1-40/50 90 Nm INDICATOR TIGHTENING TORQUE Z30/Z31/Z37/Z38 90 Nm Make sure that the filter is connected in the correct IN-OUT flow direction (shown by an arrow on the filter head). The filter housing should be preferably mounted with the bowl downward; the filter head should...
Open the catalog to page 10All FILTREC S.p.A. catalogs and technical brochures
-
F040-DMD
8 Pages
-
FS-1
4 Pages
-
F100-XD
8 Pages
-
F160-XD
8 Pages
-
F280-D1
8 Pages
-
FD-3
7 Pages
-
FDM-1
8 Pages
-
IFBW
12 Pages
-
IFD-RHR
12 Pages
-
IFD-R9
12 Pages
-
IFD-R4
12 Pages
-
IFS-RHR
12 Pages
-
IFS-R9
12 Pages
-
IFS-R4
12 Pages
-
GAS AND AIR
2 Pages
-
PCS
4 Pages
-
PPP
8 Pages
-
PMA
8 Pages
-
PCH
4 Pages
-
PCP
8 Pages
-
PBA
8 Pages
-
BOLL & KIRCH
2 Pages
-
INDICATORS
16 Pages
-
FT
8 Pages
-
FL
4 Pages
-
FB-1
4 Pages
-
FVR-7
8 Pages
-
FS-7
8 Pages
-
FR-8
8 Pages
-
FR-1
12 Pages
-
FCR-7
12 Pages
-
FA-4
8 Pages
-
FA-2
8 Pages
-
FA-1
8 Pages
-
CP-CL SERIES
4 Pages
-
WATER ABSORBENT
4 Pages
-
CORELESS
4 Pages