F280-D1-1

HYDRAULIC FILTRATION F280-D1 series In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Test 420 bar (6000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Connection Ports: 1/2”÷1 1/2” BSP (other thread options on request) Materials: Head: Bowl: Seal: cast iron extruded steel Buna-N (FKM on request) By-pass: No by-pass or 6 bar (90 psi) setting Filter Media: Microglass fiber Differential collapse pressure: 21 bar (300 psi) or 210 bar (3000 psi) (acc. to ISO 2941) The Filtrec elements are tested also according to ISO 2942 and ISO 23181 Working temperature: -25°C +120°C (-13°F +248°F) Fluid compatibility (acc. to ISO 2943): Full with HH-HL-HM-HV (acc. to ISO 6743/4). For use with other fluid applications please contact Filtrec Customer Service ([email protected]).

 Open the catalog to page 1
F280-D1-2

Ordering information MEDIA no element microglass fiber ß4,5 µm ( ) >1000 microglass fiber ß7 µm ( ) >1000 microglass fiber ß12 µm ( ) >1000 microglass fiber ß18 µm ( ) >1000 microglass fiber ß27 µm ( ) >1000 cellulose ß10 µm ( ) >2 C Filter assembly Filter element NOMINAL SIZE ELEMENT COLLAPSE INDICATOR PORT OPTION * recommended with no by-pass option. SEALS For different thread options, please check availability with Filtrec Customer Service. no by-pass 6 bar / 90 psi INDICATOR PORT OPTION no indicator port indicator port with plug indicator port on the right side with plug Optional, please...

 Open the catalog to page 2
F280-D1-3

Indicator port (option T) Indicator port option S Indicator port option S For different thread options please contact Filtrec Customer Service.

 Open the catalog to page 3
F280-D1-4

Pressure drop diagrams The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow rate. This ideally should not exceed 1,0 bar (14,5 psi) and should never exceed 1/3 of the set value of the by-pass valve. Housing F280-D120/24/21 PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. PRESSURE DROP THROUGH THE CLEAN FILTER ELEMENT Flow rate (l/min) Element D120-..-B Flow rate (gpm) The Pressure Drop through the filter element is related...

 Open the catalog to page 4
F280-D1-5

Pressure drop diagrams The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow rate. This ideally should not exceed 1,0 bar (14,5 psi) and should never exceed 1/3 of the set value of the by-pass valve. Housing F280-D140/41/43 PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. PRESSURE DROP THROUGH THE CLEAN FILTER ELEMENT Element D140-..-B Flow rate (gpm) Flow rate (l/min) The Pressure Drop through the filter element is related...

 Open the catalog to page 5
F280-D1-6

Pressure drop diagrams The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow rate. This ideally should not exceed 1,0 bar (14,5 psi) and should never exceed 1/3 of the set value of the by-pass valve. Element D143-..-A Flow rate (l/min) Flow rate (l/min) PRESSURE DROP THROUGH THE BY-PASS VALVE The by-pass valve is a safety device to prevent element collapse in case of differential pressure peaks due to flow peaks, cold start conditions or when the clogged element is not replaced in a timely manner. Flow rate (l/min) By-pass...

 Open the catalog to page 6
F280-D1-7

Clogging indicator The Pressure Drop (Dp) through the filter increases during the system operation due to the contaminant retained by the filter element. The filter element must be replaced when the indicator shows an alarm and before the Dp reaches the by-pass value setting. N.B. in cold start conditions a false alarm can be caused by higher oil viscosity due to low temperature; the indicator alarm must be considered at normal working temperature only. The differential clogging indicator registers the pressure upstream and downstream the filter element and activates a signal when the differential...

 Open the catalog to page 7
F280-D1-8

User Tips INDICATOR PORT: Visual Electric FIXING HOLES FILTER HEAD IDENTIFICATION LABEL SPARE SEAL KIT PART NUMBER NBR FKM F280-D120/24/21 06.021.00090 06.021.00135 F280-D140/41/43 06.021.00095 06.021.00137 BOWL TIGHTENING TORQUE F280-D120/24/21 65 Nm F280-D140/41/43 90 Nm INDICATOR TIGHTENING TORQUE Z30/Z31/Z32/Z33 90 Nm SEAL KIT FILTER ELEMENT FILTER BOWL Make sure that the filter is connected in the correct IN-OUT flow direction (shown by an arrow on the filter head). The filter housing should be preferably mounted with the bowl downward; the filter head should be properly secured using the...

 Open the catalog to page 8

All FILTREC S.p.A. catalogs and technical brochures

  1. F040-DMD

    8  Pages

  2. FS-1

    4  Pages

  3. F420-D1

    11  Pages

  4. F100-XD

    8  Pages

  5. F160-XD

    8  Pages

  6. FD-3

    7  Pages

  7. FDM-1

    8  Pages

  8. PPP

    8  Pages

  9. PBA

    8  Pages

  10. BOLL & KIRCH

    2  Pages

  11. CORELESS

    4  Pages

  12. IFBW

    12  Pages

  13. IFD-RHR

    12  Pages

  14. IFD-R9

    12  Pages

  15. IFD-R4

    12  Pages

  16. IFS-RHR

    12  Pages

  17. IFS-R9

    12  Pages

  18. IFS-R4

    12  Pages

  19. GAS AND AIR

    2  Pages

  20. PCS

    4  Pages

  21. PMA

    8  Pages

  22. PCH

    4  Pages

  23. PCP

    8  Pages

  24. INDICATORS

    16  Pages

  25. FT

    8  Pages

  26. FL

    4  Pages

  27. FB-1

    4  Pages

  28. FVR-7

    8  Pages

  29. FS-7

    8  Pages

  30. FR-8

    8  Pages

  31. FR-1

    12  Pages

  32. FCR-7

    12  Pages

  33. FA-4

    8  Pages

  34. FA-2

    8  Pages

  35. FA-1

    8  Pages

  36. CP-CL SERIES

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.