HYDRAULIC FILTRATION F100-XD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.5.1): F100-XD040/063/100: 100 bar (1500 psi) F100-XD160/250/400: 80 bar (1200 psi) Test (acc. to NFPA T 3.10.5.1): F100-XD040/063/100: 150 bar (2200 psi) F100-XD160/250/400: 120 bar (1750 psi) Burst (acc. to NFPA T 3.10.5.1): F100-XD040/063/100: 300 bar (4300 psi) F100-XD160/250/400: 200 bar (3000 psi) Connection Ports: 1/2”÷1 1/2” BSP (other thread options on request) Materials: Head: Bowl: Seal: aluminium alloy aluminium alloy NBR (FKM on request) Filter Media: Microglass fiber Differential collapse pressure: 21 bar (300 psi) and 210 bar (3000 psi) (acc. to ISO 2941) The Filtrec elements are tested also according to ISO 2942 and ISO 23181 Working temperature: -25°C +120°C (-13°F +248°F) Fluid compatibility (acc. to ISO 2943): Full with HH-HL-HM-HV (acc. to ISO 6743/4). For use with other fluid applications please contact Filtrec Customer Service (info@filtrec.it).

Open the catalog to page 1
F100-XD - 2

Ordering information MEDIA no element microglass fiber ß4,5 µm ( ) >1000 microglass fiber ß7 µm ( ) >1000 microglass fiber ß12 µm ( ) >1000 microglass fiber ß18 µm ( ) >1000 microglass fiber ß27 µm ( ) >1000 cellulose ß10 µm ( ) >2 C *Only for Dp 21 bar (300 psi) Filter assembly Filter element NOMINAL SIZE ELEMENT COLLAPSE INDICATOR PORT OPTION recommended with no by-pass option. For different thread options, please check availability with Filtrec Customer Service. no by-pass 6 bar / 90 psi INDICATOR PORT OPTION no indicator port indicator port with plug * Optional, please check Filtrec...

Open the catalog to page 2
F100-XD - 3

Overall dimensions Identification label Indicator port Indicator port For different thread options please contact Filtrec Customer Service.

Open the catalog to page 3
F100-XD - 4

Pressure drop diagrams The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow rate. This ideally should not exceed 1,0 bar (14,5 psi) and should never exceed 1/3 of the set value of the by-pass valve. Housing F100-XD040/063/100 PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. PRESSURE DROP THROUGH THE CLEAN FILTER ELEMENT Flow rate (l/min) Element XD063-..-B Flow rate (gpm) Flow rate (l/min) Flow rate (l/min) The...

Open the catalog to page 4
F100-XD - 5

Pressure drop diagrams The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow rate. This ideally should not exceed 1,0 bar (14,5 psi) and should never exceed 1/3 of the set value of the by-pass valve. Housing F100-XD160/250/400 PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. PRESSURE DROP THROUGH THE CLEAN FILTER ELEMENT Flow rate (l/min) The Pressure Drop through the filter element is related both to the internal...

Open the catalog to page 5
F100-XD - 6

Pressure drop diagrams By-pass F100-XD040/063/100 PRESSURE DROP THROUGH THE BY-PASS VALVE The by-pass valve is a safety device to prevent element collapse in case of differential pressure peaks due to flow peaks, cold start conditions or when the clogged element is not replaced in a timely manner. Flow rate (l/min) By-pass F100-XD160/250/400 Flow rate (gpm) 0 Flow rate (l/min) The above diagrams have been obtained at the FILTREC laboratory, according to the ISO 3968 specification, with mineral oil having 30 cSt viscosity and 0,86 Kg/dm3 density. In case of discrepancy, please check...

Open the catalog to page 6
F100-XD - 7

Clogging indicator The Pressure Drop (Dp) through the filter increases during the system operation due to the contaminant retained by the filter element. The filter element must be replaced when the indicator shows an alarm and before the Dp reaches the by-pass value setting. N.B. in cold start conditions a false alarm can be caused by higher oil viscosity due to low temperature; the indicator alarm must be considered at normal working temperature only. The differential clogging indicator registers the pressure upstream and downstream the filter element and activates a signal when the...

Open the catalog to page 7
F100-XD - 8

User Tips INDICATOR PORT: Visual Electric FIXING HOLES SPARE SEAL KIT PART NUMBER NBR FKM F100-XD040/063/100 06.021.00090 06.021.00135 F100-XD160/250/400 06.021.00096 06.021.00114 BY-PASS VALVE FILTER HEAD IDENTIFICATION LABEL BOWL TIGHTENING TORQUE F100-XD040/063/100 40 Nm F100-XD160/250/400 60 Nm INDICATOR TIGHTENING TORQUE Z30/Z31/Z32/Z33 90 Nm FILTER ELEMENT FILTER BOWL Make sure that the filter is connected in the correct IN-OUT flow direction (shown by an arrow on the filter head). The filter housing should be preferably mounted with the bowl downward; the filter head should be...

Open the catalog to page 8

All FILTREC S.p.A. catalogs and technical brochures

  1. F040-DMD

    8 Pages

  2. FS-1

    4 Pages

  3. F160-XD

    8 Pages

  4. F280-D1

    8 Pages

  5. FD-3

    7 Pages

  6. FDM-1

    8 Pages

  7. F420-D1

    11 Pages

  8. IFBW

    12 Pages

  9. IFD-RHR

    12 Pages

  10. IFD-R9

    12 Pages

  11. IFD-R4

    12 Pages

  12. IFS-RHR

    12 Pages

  13. IFS-R9

    12 Pages

  14. IFS-R4

    12 Pages

  15. GAS AND AIR

    2 Pages

  16. PCS

    4 Pages

  17. PPP

    8 Pages

  18. PMA

    8 Pages

  19. PCH

    4 Pages

  20. PCP

    8 Pages

  21. PBA

    8 Pages

  22. BOLL & KIRCH

    2 Pages

  23. INDICATORS

    16 Pages

  24. FT

    8 Pages

  25. FL

    4 Pages

  26. FB-1

    4 Pages

  27. FVR-7

    8 Pages

  28. FS-7

    8 Pages

  29. FR-8

    8 Pages

  30. FR-1

    12 Pages

  31. FCR-7

    12 Pages

  32. FA-4

    8 Pages

  33. FA-2

    8 Pages

  34. FA-1

    8 Pages

  35. CP-CL SERIES

    4 Pages

  36. CORELESS

    4 Pages