![FILT AIR - logo](https://img.directindustry.com/images_di/logo-p/L28707.gif)
Catalog excerpts
![Panel Filter GP - 1](https://img.directindustry.com/pdf/repository_di/28707/panel-filter-gp-631780_1m.jpg)
Panel Finedust / HEPA Filter Type GP Overview The GP filter is designed and tested to extract the smallest particles out of the air. The GP series contains a fibreglass media pack in four (4) different heights (47mm, 56mm, 70mm, and 93mm) and in different kinds of extruded aluminium frames. The filter media is pleated in ‘Minipleat shape’ with a new application technology of ‘Hot Melt Spacers’ to achieve the lowest pressure drop results. FEATURES • HEPA efficiencies of 95% up to 99.99995% (@ 0.3 μm) • Finedust efficiencies of 60% up to 98% ASHRAE • Lowest initial pressure drop Fine Dust Filter • Rigid frames Finedust - HEPA / ULPA • High quality micro-fibreglass paper Final Filter for Fan Filter Units Final Filter for Clean Rooms Final Filter for Channel Installation Highly Active Filter Surface - Low Pressure Drop Final Filter for Grid Systems
Open the catalog to page 1![Panel Filter GP - 2](https://img.directindustry.com/pdf/repository_di/28707/panel-filter-gp-631780_2m.jpg)
Finedust - HEPA Filter Type GP • HEPA efficiencies of 95% up to 99.99995% (@ 0.3 μm ) • Finedust efficiencies of 60% up to 98% ASHRAE • High quality micro fibreglass paper • Lowest initial pressure drop • Rigid frames • Frame height of 70 mm up to 197 mm FEATURES • High quality standards due to Quality Assurance System • Frame heights • HEPA filter tested by laser particle counting system • of 70 mm up to 197 mm • High quality standards due to Quality Assurance System • HEPA filter tested by laser particle counting system • Highly economical through high final pressure drop • For use in...
Open the catalog to page 2![Panel Filter GP - 3](https://img.directindustry.com/pdf/repository_di/28707/panel-filter-gp-631780_3m.jpg)
APPLICABLE STANDARDS: Testing The prefilters are tested in accordance with European Standard EN 779 (Particulate air filters for general ventilation). This standard is based on ASHRAE 52.1 (Gravimetric and Dust-Spot Procedures for Testing Air Cleaning Devices Used in General Ventilation for Removing Particulate Matter, 1992). XY - Scan Testing Device Filt Air XY-scan testing device is able to perform automated filter leak testing of high efficiency air filters using automatic particle counters and a motorized scan table. While the particle counter probe passes over the filter face, the...
Open the catalog to page 3![Panel Filter GP - 4](https://img.directindustry.com/pdf/repository_di/28707/panel-filter-gp-631780_4m.jpg)
Technical Data Finedust Filter Data Rated Face Velocity Media Pack Initial pressure drop @ rated airflow Filter class as per EN 779 Atmospherical dust-spot efficiency @ Rated airflow: average (final pressure drop 450 Pa) Recommended final pressure drop HEPA Filter Data (low velocity) Rated face velocity Media Pack Initial pressure drop @ rated airflow Filter class as per EUROVENT 4/4 Initial efficiency @ rated airflow Test with MPPS (integral) Test with aerosol Ø 0.3 μm (integral) Recommended final pressure drop Flammability classification to DIN 53438 Max. relative humidity Specifications...
Open the catalog to page 4![Panel Filter GP - 5](https://img.directindustry.com/pdf/repository_di/28707/panel-filter-gp-631780_5m.jpg)
Initial Pressure Drop
Open the catalog to page 5![Panel Filter GP - 6](https://img.directindustry.com/pdf/repository_di/28707/panel-filter-gp-631780_6m.jpg)
Dimensional Drawing
Open the catalog to page 6![Panel Filter GP - 7](https://img.directindustry.com/pdf/repository_di/28707/panel-filter-gp-631780_7m.jpg)
Order Code Dimensional Sketch of Profiles Side A Special profile with 'knife edge' (suitable for 'fluid seal' system) for GP filters with Media Pack Order Code 4 Standard profile for GP filters with Media Pack Order Code 4 Standard profile for GP filters with Media Pack Order Code 4 or 5 Special profile with ‘fluid seal’ (suitable for ‘knife edge’ system) for GP filters with Media Pack Order Code 4, 5, 7, or 9 Special profile with ‘knife edge’ (suitable for ‘fluid seal’ system) for GP filters with Media Pack Order Code 4, 5, 7, or 9 Standard profile for GP filters with Media Pack Order Code...
Open the catalog to page 7![Panel Filter GP - 8](https://img.directindustry.com/pdf/repository_di/28707/panel-filter-gp-631780_8m.jpg)
Order Numbers Order no. Media Pack Screen Material No Screen/ Media at Profile Side A 1x Screen/ Media at Profile Side A 1x Screen/ Media at Profile Side B 2x Screen/ Media at Profile Side A Exp. Steel/ Powder Coated No Screen/ Media at Profile Side B 2x Screen/ Media at Profile Side B 1x Fluid, Side A 1x Dry, Side B Other dimensions available upon request Specifications are subject to change without prior notice HEPA & ULPA Filters for Industrial Clean Rooms FILT AIR Ltd. specializes in the use of advanced technologies to implement a purified air supply for high-tech industry clean rooms,...
Open the catalog to page 8All FILT AIR catalogs and technical brochures
-
Bipolar Ionization
2 Pages
-
Filt Air’s
8 Pages
-
Safe Change Housing Type H0
4 Pages
-
GH – High Temperature Filter
2 Pages
-
Gas Absorption Filters CP
4 Pages
-
GRV Conical Filters
4 Pages
-
Cylindrical Filter GR0
4 Pages
-
GTS Terminal Filters
8 Pages
-
HT Terminal Filters
8 Pages
-
Compact Filter GV8 (H10-H14)
4 Pages
-
Compact Filter GW
8 Pages
-
Compact Filter GV8 (F6 – F9)
4 Pages
-
Compact Carbon Filter CV8
4 Pages
-
Compact HEPA Filter Type G17
4 Pages
-
Type G09
4 Pages
-
Type CV8 full plastic frame
4 Pages
-
Finedust Filter Type G90
4 Pages
-
GT Terminal Filters
8 Pages
-
GRV Conical Finedust Filters
4 Pages
-
Finedust Filter G90
4 Pages
-
Bag Filter G80
2 Pages
-
Compact filter G7
8 Pages
-
Type GRO
4 Pages
-
Type HT
6 Pages
-
Type GP
8 Pages
-
Type GW
6 Pages
-
Type GVA
4 Pages