Product Overview:
The TGS2611-E00 is a semiconductor gas sensor designed for detecting methane. It is suitable for use in domestic gas alarms, portable gas detectors, and gas leak detectors for appliances. The sensor is noted for its high selectivity to methane, low power consumption, long life, and cost-effectiveness. It operates using a simple electrical circuit.

Specifications:
- Model: TGS2611-E00
- Sensing Principle: MOS type
- Package: TO-5 metal can
- Target Gases: Methane, Natural Gas
- Detection Range: 1~25% LEL
- Heater Voltage (VH): 5.0±0.2V AC/DC
- Circuit Voltage (VC): 5.0±0.2V DC
- Load Resistance (RL): Variable, 0.45kΩ min.
- Heater Resistance (RH): Approx 59Ω at room temperature
- Heater Current (IH): 56±5mA
- Heater Power Consumption (PH): 280mW±25mW
- Sensor Resistance (RS): 0.83~8.30kΩ in 5000ppm methane
- Sensitivity: 0.52~0.65 in methane

Operating Conditions:
The sensor's performance can vary based on specific applications. It is recommended to consult Figaro's technical staff before deployment, especially if target gases are not listed. The sensor is compliant with performance standards such as UL1484 and EN50194.

Temperature and Humidity Dependency:
The sensor's resistance ratio (Rs/Ro) varies with temperature and humidity. Rs is the sensor resistance at various conditions, while Ro is the resistance in 5000ppm of methane at 20˚C/65%RH.

Electrical Characteristics:
The sensor requires two voltage inputs: heater voltage (VH) and circuit voltage (VC). A common power supply can be used for both. The load resistor (RL) should be optimized to maintain power dissipation below 15mW.

Structure and Dimensions:
The sensor is housed in a TO-5 package with specific pin connections for the heater and sensor electrodes. Detailed dimensions are provided for integration into devices.

Important Note:
Actual sensor characteristics may vary, and only those in the specification table are warranted. Users are advised to read the warranty statements available on Figaro's website.
See more

Catalog excerpts

TGS2611-E00-1

PRODUCT INFORMATION TGS 2611-E00 - for the detection of Methane Features: * High selectivity to methane * Low power consumption * Long life and low cost * Uses simple electrical circuit * Domestic gas alarms * Portable gas detectors * Gas leak detector for gas appliances TGS2611-E00 is a semiconductor type gas sensor which combines very high sensitivity to methane gas with low power consumption and long life. Due to miniaturization of its sensing chip, TGS2611-E00 requires a heater current of only 56mA and the device is housed in a standard TO-5 package. TGS2611-E00 uses filter material in its housing which eliminates the influence of interference gases such as alcohol, resulting in highly selective response to methane gas. This feature makes the sensor ideal for residential gas leakage detectors which require durability and resistance against interference gas. The TGS2611-E00 is able to satisfy the requirements of performance standards such as UL1484 and EN50194. The figure below represents typical sensitivity characteristics, all data having been gathered at standard test conditions (see reverse side of this sheet). The Y-axis is indicated as sensor resistance ratio (Rs/Ro) which is defined as follows: Rs = Sensor resistance at various concentrations Ro = Sensor resistance in 5000ppm of methane Sensitivity Characteristics: The figure below represents typical temperature and humidity dependency characteristics. The Y-axis is indicated as sensor resistence ratio (Rs/Ro), defined as follows: Rs = Sensor resistance in 5000ppm of methane at various temp/humidities Ro = Sensor resistance in 5000ppm of methane at 20˚C/65%RH Temperature and Humidity Dependency: 10 IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY WITH EACH CUSTOMER’S SPECIFIC APPLICATIONS. FIGARO STRONGLY RECOMMENDS CONSULTING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND, IN PARTICULAR, WHEN CUSTOMER’S TARGET GASES ARE NOT LISTED HEREIN. FIGARO CANNOT ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR WHICH SENSOR HAS NOT BEEN SPECIFICALLY TESTED BY FIGARO.

 Open the catalog to page 1
TGS2611-E00-2

Basic Measuring Circuit: The sensor requires two voltage inputs: heater voltage (Vh) and circuit voltage (Vc). The heater voltage (Vh) is applied to the integrated heater in order to maintain the sensing element at a specific temperature which is optimal for sensing. Circuit voltage (Vc) is applied to allow measurement of voltage Vout(Vrl) across a load resistor (Rl) which is connected in series with the sensor._ A common power supply circuit can be used for both Vc and Vh to fulfill the sensor's electrical requirements. The value of the load resistor (Rl) should be chosen to optimize the alarm...

 Open the catalog to page 2

All Figaro Engineering Inc. catalogs and technical brochures

  1. TGS2600

    2  Pages

  2. TGS2603

    2  Pages

  3. TGS2602

    2  Pages

  4. TGS 2630

    2  Pages

  5. TGS2620

    2  Pages

  6. TGS2611-C00

    2  Pages

  7. TGS2610-C00

    2  Pages

  8. TGS2610-D00

    2  Pages

  9. TGS2612

    2  Pages

  10. KE-12

    2  Pages

  11. KE-25

    2  Pages

  12. KE-25F3

    2  Pages

  13. KE-50

    2  Pages

  14. KE-25LF

    2  Pages

  15. KE-25F3LF

    2  Pages

  16. TGS5042

    2  Pages

  17. FECS50-100

    2  Pages

  18. FECS45-10

    2  Pages

  19. FECS44-5000

    2  Pages

  20. FECS44-1000

    2  Pages

  21. FECS44-200

    2  Pages

  22. FECS44-100

    2  Pages

  23. FECS41-250

    2  Pages

  24. FECS40-1000

    2  Pages

  25. CMM5042

    2  Pages

  26. FCM2630-C01

    2  Pages

  27. TGS5141-P00

    2  Pages

  28. TGS3830

    2  Pages

  29. TGS8100

    2  Pages

  30. NGM2611-E13

    3  Pages

  31. FECS42-20

    2  Pages

  32. FECS43-20

    2  Pages

  33. LPM2610-D09

    3  Pages

  34. CGM6812-B00

    2  Pages

  35. TGS6810-D00

    2  Pages

  36. FCM2630-E00

    2  Pages

  37. TGS6812-D00

    2  Pages

  38. TGS3870

    2  Pages

  39. SK-25F

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.