TGS2610-C00
2Pages

{{requestButtons}}

Catalog excerpts

TGS2610-C00 - 1

PRODUCT INFORMATION * Quick response * Low power consumption * Long life and low cost * Uses simple electrical circuit * Portable LP gas detectors * LP gas and vapor detection TGS2610-C00 is a semiconductor type gas sensor which combines very high sensitivity to LP gas with low power consumption and long life. Due to miniaturization of its sensing chip, TGS2610-C00 requires a heater current of only 56mA and the device is housed in a standard TO-5 package. TGS2610-C00 possesses small size and quick gas response, making it suitable for gas leakage checkers. The TGS2610-C00 is able to satisfy the requirements of performance standards such as UL1484 and EN50194. The figure below represents typical sensitivity characteristics, all data having been gathered at standard test conditions (see reverse side of this sheet). The Y-axis is indicated as sensor resistance ratio (Rs/Ro) which is defined as follows: Rs = Sensor resistance at various concentrations Ro = Sensor resistance in 1800ppm of iso-butane The figure below represents the typical response pattern when the sensor is inserted into and later removed from 1800ppm of iso-butane. Sensitivity Characteristics: Ethanol Hydrogen Methane Iso-butane Propane Gas concentration (ppm) IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY WITH EACH CUSTOMER’S SPECIFIC APPLICATIONS. FIGARO STRONGLY RECOMMENDS CONSULTING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND, IN PARTICULAR, WHEN CUSTOMER’S TARGET GASES ARE NOT LISTED HEREIN. FIGARO CANNOT ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR WHICH SENSOR HAS NOT BEEN SPECIFICALLY TESTED BY FIGA

Open the catalog to page 1
TGS2610-C00 - 2

Basic Measuring Circuit: The sensor requires two voltage inputs: heater voltage (Vh) and circuit voltage (Vc). The heater voltage (Vh) is applied to the integrated heater in order to maintain the sensing element at a specific temperature which is optimal for sensing. Circuit voltage (Vc) is applied to allow measurement of voltage (Vout) across a load resistor (Rl) which is connected in series with the sensor. A common power supply circuit can be used for both Vc and Vh to fulfill the sensor's electrical requirements. The value of the load resistor (Rl) should be chosen to optimize the alarm...

Open the catalog to page 2

All Figaro Engineering Inc. catalogs and technical brochures

  1. TGS2600

    2 Pages

  2. TGS2603

    2 Pages

  3. TGS2602

    2 Pages

  4. TGS 2630

    2 Pages

  5. TGS2620

    2 Pages

  6. TGS2611-E00

    2 Pages

  7. TGS2611-C00

    2 Pages

  8. TGS2610-D00

    2 Pages

  9. TGS2612

    2 Pages

  10. KE-12

    2 Pages

  11. KE-25

    2 Pages

  12. KE-25F3

    2 Pages

  13. KE-50

    2 Pages

  14. KE-25LF

    2 Pages

  15. KE-25F3LF

    2 Pages

  16. TGS5042

    2 Pages

  17. FECS50-100

    2 Pages

  18. FECS45-10

    2 Pages

  19. FECS44-5000

    2 Pages

  20. FECS44-1000

    2 Pages

  21. FECS44-200

    2 Pages

  22. FECS44-100

    2 Pages

  23. FECS41-250

    2 Pages

  24. FECS40-1000

    2 Pages

  25. CMM5042

    2 Pages

  26. FCM2630-C01

    2 Pages

  27. TGS5141-P00

    2 Pages

  28. TGS3830

    2 Pages

  29. TGS8100

    2 Pages

  30. NGM2611-E13

    3 Pages

  31. FECS42-20

    2 Pages

  32. FECS43-20

    2 Pages

  33. LPM2610-D09

    3 Pages

  34. CGM6812-B00

    2 Pages

  35. TGS6810-D00

    2 Pages

  36. FCM2630-E00

    2 Pages

  37. TGS6812-D00

    2 Pages

  38. TGS3870

    2 Pages

  39. SK-25F

    2 Pages