PRODUCT INFORMATION TGS 2600 - for the detection of Air Contaminants Features: * Low power consumption * High sensitivity to gaseous air contaminants * Long life and low cost * Uses simple electrical circuit * Small size * Air cleaners * Ventilation control * Air quality monitors The sensing element is comprised of a metal oxide semiconductor layer formed on an alumina substrate of a sensing chip together with an integrated heater. In the presence of a detectable gas, the sensor's conductivity increases depending on the gas concentration in the air. A simple electrical circuit can convert the change in conductivity to an output signal which corresponds to the gas concentration. The TGS 2600 has high sensitivity to low concentrations of gaseous air contaminants such as hydrogen and carbon monoxide which exist in cigarette smoke. The sensor can detect hydrogen at a level of several ppm. Due to miniaturization of the sensing chip, TGS 2600 requires a heater current of only 42mA and the device is housed in a standard TO-5 package. The figure below represents typical sensitivity characteristics, all data having been gathered at standard test conditions (see reverse side of this sheet). The Y-axis is indicated as sensor resistance ratio (Rs/Ro) which is defined as follows: Rs = Sensor resistance in displayed gases at various concentrations Ro = Sensor resistance in fresh air The figure below represents typical temperature and humidity dependency characteristics. Again, the Y-axis is indicated as sensor resistance ratio (Rs/Ro), defined as follows: Rs = Sensor resistance in fresh air at various temperatures/humidities Ro = Sensor resistance in fresh air at 20°C and 65% R.H. Sensitivity Characteristics: Temperature/Humidity Dependency: Iso-butane Ethanol Hydrogen IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY WITH EACH CUSTOMER’S SPECIFIC APPLICATIONS. FIGARO STRONGLY RECOMMENDS CONSULTING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND, IN PARTICULAR, WHEN CUSTOMER’S TARGET GASES ARE NOT LISTED HEREIN. FIGARO CANNOT ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR WHICH SENSOR HAS NOT BEEN SPECIFICALLY TESTED BY FIGA
Open the catalog to page 1Basic Measuring Circuit: The sensor requires two voltage inputs: heater voltage (Vh) and circuit voltage (Vc). The heater voltage (Vh) is applied to the integrated heater in order to maintain the sensing element at a specific temperature which is optimal for sensing. Circuit voltage (Vc) is applied to allow measurement of voltage (Vout) across a load resistor (Rl) which is connected in series with the sensor. DC voltage is required for the circuit voltage since the sensor has a polarity. A common power supply circuit can be used for both Vc and Vh to fulfill the sensor’s electrical...
Open the catalog to page 2All Figaro Engineering Inc. catalogs and technical brochures
-
TGS2603
2 Pages
-
TGS2602
2 Pages
-
TGS 2630
2 Pages
-
TGS2620
2 Pages
-
TGS2611-E00
2 Pages
-
TGS2611-C00
2 Pages
-
TGS2610-C00
2 Pages
-
TGS2610-D00
2 Pages
-
TGS2612
2 Pages
-
KE-12
2 Pages
-
KE-25
2 Pages
-
KE-25F3
2 Pages
-
KE-50
2 Pages
-
KE-25LF
2 Pages
-
KE-25F3LF
2 Pages
-
TGS5042
2 Pages
-
FECS50-100
2 Pages
-
FECS45-10
2 Pages
-
FECS44-5000
2 Pages
-
FECS44-1000
2 Pages
-
FECS44-200
2 Pages
-
FECS44-100
2 Pages
-
FECS41-250
2 Pages
-
FECS40-1000
2 Pages
-
CMM5042
2 Pages
-
FCM2630-C01
2 Pages
-
TGS5141-P00
2 Pages
-
TGS3830
2 Pages
-
TGS8100
2 Pages
-
NGM2611-E13
3 Pages
-
FECS42-20
2 Pages
-
FECS43-20
2 Pages
-
LPM2610-D09
3 Pages
-
CGM6812-B00
2 Pages
-
TGS6810-D00
2 Pages
-
FCM2630-E00
2 Pages
-
TGS6812-D00
2 Pages
-
TGS3870
2 Pages
-
SK-25F
2 Pages