Overview: The document provides technical specifications and data for the FMSC System family, which includes the FMSC Master and FMSC Slave. These are programmable controllers designed for both safe and non-safe applications, adhering to safety standards such as SIL 3 (IEC61508) and pl e EN ISO 13849-1.
Electrical Specifications: The FMSC Master and Slave operate on a 24V DC power supply with a tolerance range of 18 to 30V DC and a typical current consumption of 20 mA. They feature a micro USB interface for programming and diagnostics.
Inputs and Outputs: The system includes 12 inputs and a combination of 4 safe and 5 standard outputs. Inputs are not galvanically isolated and have specific signal levels for logic "0" and "1". Outputs are electronically short-circuit protected and status is indicated via LEDs.
Mechanical Specifications: The devices are designed to be mounted on a top hat rail, with a protection class of IP 20 for both housing and terminals. The dimensions are 114.5 x 22.5 x 99 mm, and the weight is 130 grams (170 grams with connectors).
Environmental Conditions: The operating temperature range is 0 to +55°C, with storage temperatures from -25°C to +70°C. The system can handle relative humidity from 10% to 95% RH, but condensation is not allowed.
Technical Data: The system supports various sensors, including linear and rotary encoders, with specific resolutions and minimum speed requirements. It also includes a range of function elements for safety and operational monitoring.
Type Overview: The document outlines different configurations and expandability options for the FMSC system, including connections to multiple slaves and various master types (Basic, Advanced, Profi).
See more

Catalog excerpts

FMSC Systemfamily-1

Techical specification scope of application Safety design of hardware Electrical specification Power supply Tolerance range Current consumption Fuse for power supply Terminal connection power supply input level output level Interface Inputs Number of inputs Galvanic isolation Signal level at log "0" Signal level at log "1" Input current min impulse duration Status displayed via Outputs - safe Number of outputs - safe Galvanic isolation Output current at log "1" Short circuit protection Status displayed via Outputs - Standard Number of outputs - standard Galvanic isolation Output current at log "1" Short circuit protection Status displayed via FMSC Master FMSC Slave Programmable controller for safe and non safe applications SIL 3 (IEC61508), pl e EN ISO 13849-1 FMSC Master FMSC Slave 24V DC 18 ... 30,0 V DC max. 10% ripple typ. 20 mA T 20 A extern screw- or spring type max. 2,5 mm2 max. 1,5 mm2 max. 2,5 mm2 Mirco USB for programming, hardware diagnosis and Debug-Mode FMSC Master FMSC Slave 6 (24V) and 6 (24V oder 5V) no 0 ... 8V DC at 24V 0 ... 1,5V DC at 5V 15 ... 28V DC at 24V 3,5 ... 6V DC at 5V 4 mA (at 24V) 0,5 ms LED FMSC Master FMSC Slave 4 no max. 4 A electronically LED FMSC Master FMSC Slave 5 no max. 0,5 A electronically LED

 Open the catalog to page 1
FMSC Systemfamily-2

Mechanical specification Design size (hxbxt) without connectors Installation on top hat rail Protection class housing Protection class terminals Weight Environmental conditions Operating temperature range Storage temperature range Relative humidity Creep distance Oscillation EMC Condensation Technical data Number of counter inputs Typ of sensors Signal voltage Resolution linear encoder Resolution rotary encoder The smallest possible speed with linear encoder The smallest possible speed with rotary encoder Number of pulse counter FIESSLER ELEKTRONIK

 Open the catalog to page 2
FMSC Systemfamily-3

Overview about FMSC function elements ! Emergency stop Safety gate monitoring Operating mode selector switch Operating console evaluation Valve monitoring dynamically or static Safety light curtain evaluation Monoflop rising or falling edge Two hand control monitoring Timer Counter upward Fiessler AKAS evaluation Decimal / binaryr or Binary / Decimal converter FMSC Systemfamily Technical data Fiessler BLVT programming Fiessler AKAS muting system Overrun distance measurement via counter Direction and stop monitoring Brake ramp monitoring PSDI mode (1 up to 4 breaks) Safety foot pedals

 Open the catalog to page 3
FMSC Systemfamily-4

FMSC Basic Master! FMSC Advanced Master! FMSC Profi Master ! FMSC Advanced Master! FMSC Profi Master FMSC Slave FMSC ADVANCED FMSC Slave FMSC BASIC Connection to Master! type of slaves Connection overview implemented! !! implemented! ! with communication Slave PSDI - mode! ! Muting - application! ! ! BLVT - application FMSC Master FMSC ADVANCED 12 inputs! 4 safe outputs! 5 standard outputs! ! ... up to 8 slaves! ! configurable! ! ! configurable! ! ! 1 Axis / Master FMSC Master FMSC ADVANCED FMSC Master FMSC BASIC FMSC Master FMSC ECO Software overview FMSC Master FMSC BASIC 12 inputs! 4 safe outputs!...