Catalog excerpts
fibroMAT Heavy-load positioning tables data sheet collection
Open the catalog to page 1FIBROMAT® AT.0800 Dimensions of FIBROMAT® AT.0800 (Drive arrangement 180° with one drive; for other drive arrangements, diagrams or CAD data are available) Technical data for FIBROMAT AT.0800 ® 1 drive without motor 1 drive with motor 1 drive with motor 1 drive with motor 2 drives without motor 2 drives with motor 2 drives with motor 2 drives with motor Drive arrangement Drive motor See pictures above Special design Without indexing unit With indexing unit for division XX, symmetrical arrangement Special division Centre hole Ø 320 mm Extended by 200 mm (not combinable with standard indexing...
Open the catalog to page 2FIBROMAT® AT.0800 Technical data for FIBROMAT® AT.0800 Maximum axial runout of the table top 0.05 mm Maximum runout of the centre hole Weight 0.05 mm FIBROMAT AT.0800 Gear motor Indexing unit Indexing times for FIBROMAT® AT.0800 AT.0800 with one drive 45° ts in s J in kgm2 90° ts in s J in kgm2 180° ts in s J in kgm2 The specified switching times do not include: Regulation time of 0.1 sec, indexing time of 0.3 sec. Further angels and indexing times can be calculated for you. Load data for FIBROMAT® AT.0800 Perm. transport load on table top horizontal Perm. superstructure diameter Perm....
Open the catalog to page 3FIBROMAT® AT.1000 Dimensions of FIBROMAT® AT.1000 (Drive arrangement 180° with one drive; for other drive arrangements, diagrams or CAD data are available) Technical data for FIBROMAT AT.1000 ® 1 drive without motor 1 drive with motor 1 drive with motor 1 drive with motor 2 drives without motor 2 drives with motor 2 drives with motor 2 drives with motor Drive arrangement Drive motor See pictures above Special design Without indexing unit With indexing unit for division XX, symmetrical arrangement Special division Centre hole Ø 520 mm Extended by 200 mm (not combinable with standard indexing...
Open the catalog to page 4FIBROMAT® AT.1000 Technical data for FIBROMAT® AT.1000 Maximum axial runout of the table top 0.05 mm Maximum runout of the centre hole Weight 0.05 mm FIBROMAT AT.1000 Gear motor Indexing unit Indexing times for FIBROMAT® AT.1000 AT.1000 with one drive 45° ts in s J in kgm2 90° ts in s J in kgm2 180° ts in s J in kgm2 The specified switching times do not include: Regulation time of 0.1 sec, indexing time of 0.3 sec. Further angels and indexing times can be calculated for you. Load data for FIBROMAT® AT.1000 Perm. transport load on table top horizontal Perm. superstructure diameter Perm....
Open the catalog to page 5FIBROMAT® AT.1250 Dimensions of FIBROMAT® AT.1250 (Drive arrangement 180° with one drive; for other drive arrangements, diagrams or CAD data are available) Technical data for FIBROMAT AT.1250 ® 1 drive without motor 1 drive with motor 1 drive with motor 1 drive with motor 2 drives without motor 2 drives with motor 2 drives with motor 2 drives with motor Drive arrangement Drive motor See pictures above Special design Without indexing unit With indexing unit for division XX, symmetrical arrangement Special division Centre hole Ø 770 mm Extended by 200 mm (not combinable with standard indexing...
Open the catalog to page 6FIBROMAT® AT.1250 Technical data for FIBROMAT® AT.1250 Maximum axial runout of the table top 0.07 mm Maximum runout of the centre hole Weight 0.07 mm FIBROMAT AT.1250 Gear motor Indexing unit Indexing times for FIBROMAT® AT.1250 AT.1250 with one drive 45° ts in s J in kgm2 90° ts in s J in kgm2 180° ts in s J in kgm2 The specified switching times do not include: Regulation time of 0.1 sec, indexing time of 0.3 sec. Further angels and indexing times can be calculated for you. Load data for FIBROMAT® AT.1250 Perm. transport load on table top horizontal Perm. superstructure diameter Perm....
Open the catalog to page 7FIBROMAT® AT.1600 Dimensions of FIBROMAT® AT.1600 (Drive arrangement 180° with one drive; for other drive arrangements, diagrams or CAD data are available) Technical data for FIBROMAT AT.1600 ® 1 drive without motor 1 drive with motor 1 drive with motor 1 drive with motor 2 drives without motor 2 drives with motor 2 drives with motor 2 drives with motor Drive arrangement Drive motor See pictures above Special design Without indexing unit With indexing unit for division XX, symmetrical arrangement Special division Centre hole Ø 1,000 mm Extended by 200 mm (not combinable with standard...
Open the catalog to page 8FIBROMAT® AT.1600 Technical data for FIBROMAT® AT.1600 Maximum axial runout of the table top 0.1 mm Maximum runout of the centre hole Weight 0.1 mm FIBROMAT AT.1600 Gear motor Indexing unit Indexing times for FIBROMAT® AT.1600 AT.1600 with one drive 45° ts in s J in kgm2 90° ts in s J in kgm2 180° ts in s J in kgm2 The specified switching times do not include: Regulation time of 0.1 sec, indexing time of 0.3 sec. Further angels and indexing times can be calculated for you. Load data for FIBROMAT® AT.1600 Perm. transport load on table top horizontal Perm. superstructure diameter Perm. force...
Open the catalog to page 9All FIBRO GmbH catalogs and technical brochures
-
Flex Cam Unit
88 Pages
-
RECIRCULATING BALL BUSHES
12 Pages
-
THE CLEVER OPTION PILLAR CAM
2 Pages
-
AERIAL CAM UNIT 2016.27.
38 Pages
-
Standard parts
1355 Pages
-
Guide Elements
330 Pages
-
GROUND PRECISION COMPONENTS
247 Pages
-
NUOVI PRODOTTI NELL´AREA CURSORI
197 Pages
-
COMPOSITE PLATE SYSTEM
32 Pages
-
Composite Plate System
32 Pages
-
Catalog PDF (Peripherie)
63 Pages
-
Catalog PDF (Elastomer)
33 Pages
-
Catalog PDF (Fibrochemie)
21 Pages
-
Standard Parts SYNOPSIS
32 Pages
Archived catalogs
-
Electro-mechanical transporters
12 Pages
-
Pneumatic transporters
4 Pages
-
BOLT LOCK SYSTEM
16 Pages
-
Spacer for die release
4 Pages
-
Projection Planning Manual
64 Pages
-
Standard Parts SYNOPSIS
16 Pages
-
ROTARY TABLES
7 Pages
-
Spring Plungers
4 Pages
-
2490.14. Compact gas springs
6 Pages
-
In-Die Tapping Units (FTU)
12 Pages