Product Rating Summary Rating Definitions Prime: These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and these models can supply 10% overload power for 1 hour in 12 hours. Standby: These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternators on these models are peak continuous rated (as defined in ISO 8528-3). Emergency Rating: These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure, up to a maximum of 200 hours per year. No overload is permitted on these ratings. Exceeding 200 hours operation per year may result in a reduced product life. Engine Nomenclature Please note where engine model names incorporate an A, C or D: ‘A’ Indicates – Optimised for low fuel consumption (low BSFC). ‘C’ Indicates – Low Emissions – EU Stage II emissions compliant. ‘D’ Indicates – L ow Emissions – EU Stage IIIa emissions compliant. L = Length W = Width H = Height Weights and Dimensions refer to open generator sets only.
Open the catalog to page 1F Series Ratings 50 Hz Generator Set Model Engine Model Standard Alternator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Fillable Fuel Tank Capacity l (US gal) Dry weight = with lube oil, Wet weight = with lube oil and coolant, no fuel.
Open the catalog to page 2400 Series Ratings 50 Hz Generator Single Phase 230V @ 50 Hz, 240V @ 60 Hz – Ratings at 1.0 Power Factor P7.5-4S Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Single Phase Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 31103 Series Ratings 50 Hz Generator Single Phase 230V @ 50 Hz, 240V @ 60 Hz – Ratings at 1.0 Power Factor P26-3S Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Generator Set Model Fillable Fuel Capacity: Single Phase Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 41104 Series Ratings 50 Hz Generator Single Phase 230V @ 50 Hz, 240V @ 60 Hz – Ratings at 1.0 Power Factor P55-6S Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Single Phase Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 51106 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 61306 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 71606 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 82206 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 92506 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 102806 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 114006 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 124008 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 134012 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant.
Open the catalog to page 144016 Series Ratings 50 Hz Generator Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Weights and Dimensions Length (L): Fillable Fuel Capacity: Dry = With Lube Oil, Wet = With Lube Oil and Coolant. FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India • USA With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network. To contact your local Sales Office please visit the FG Wilson website at www.FGWilson.com. FG Wilson is a trading name of Caterpillar (NI) Limited In line with our policy...
Open the catalog to page 1524 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
20 Pages
4 Pages
16 Pages
16 Pages
12 Pages
4 Pages
4 Pages
2 Pages
4 Pages
3 Pages
4 Pages
24 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
16 Pages
16 Pages
20 Pages
4 Pages
7 Pages
16 Pages
16 Pages
4 Pages
3 Pages
2 Pages
2 Pages