1. Catalogs
  2. FG WILSON
  3. PG750B Gas generator set
video corpo

PG750B Gas generator set

PG750B Gas generator set

PG750B Gas generator set

Product catalog summary
Engine and Alternator Specifications
The generating set model PG750B is powered by a Perkins 4012TESI engine and a Leroy Somer alternator model LL7024P. It operates at a frequency of 50 Hz with an engine speed of 1500 RPM. The control panel used is PowerWizard 2.0, and the base frame is made of heavy-duty fabricated steel. The circuit breaker is a 3 Pole MCCB.
Dimensions and Weight
The dimensions of the unit are 5585 mm in length, 2198 mm in width, and 2601 mm in height. The wet weight is 8700 kg.
Performance and Ratings
The generating set provides a baseload of 750 kVA / 600 kW at 380-415V, 50 Hz. It adheres to standards such as ISO 8528, ISO 3046, IEC 60034, BS5000, and NEMA MG-1/22. The engine has a compression ratio of 9.5:1 and a displacement of 45.84 liters. It is turbocharged and water-cooled.
Fuel and Cooling Systems
The engine uses natural gas with a lower calorific value of 34.7 MJ/m³. The cooling system has a capacity of 135 liters and is designed to operate in ambient conditions up to 40°C. The lubrication system has a total oil capacity of 178 liters.
Exhaust and Emissions
The exhaust system includes a Level 1 silencer model SD150, with a noise reduction level of 18 dBA. The exhaust gas flow is 127 m³/min with a temperature of 424°C.
Alternator Data
The alternator has a single bearing, insulation class H, and a winding pitch code of 2/3. It features a shunt excitation system with an AVR model R450. The voltage regulation is +/- 0.5%.
Options and Accessories
FG Wilson offers various optional features such as CE certification upgrades, sound attenuated containers, additional alarms, and different exhaust silencer noise levels.
General Information
The equipment comes with full operation and maintenance manuals and meets several international standards. FG Wilson provides a full manufacturer's warranty with extended terms available.
See more

Catalog excerpts

PG750B Gas generator set-1

Output Ratings Baseload (Continuous) Rating These ratings are applicable for supplying continuous electrical power for full load operations. There is no overload available. The ratings represent the engine performance in accordance with ISO 3046 at reference conditions equivalent to those specified in ISO 3046/1 based on the use of natural gas having a lower calorific value of 34.71 MJ/nr Ratings and Performance Data Engine Make and Model Alternator Model: Control Panel: Base Frame: Circuit Breaker Type/Rating: Leroy Somer Heavy Duty Fabricated Steel Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328ft) A.S.L. 30% relative humidity. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load using gas fuel with a lower calorific value of 34.71 MJ/nr Available Options FG Wilson offer a range of optional features to tailor our generating sets to meet your power needs. Options include: • A wide range of Sound Attenuated Containers • A variety of generating set control and synchronising panels • Additional alarms and shutdowns • A selection of exhaust silencer noise levels For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit: Dry = With Lube Oil Wet = With Lube Oil and Coolant Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1/22. Generating set pictured may include optional accessories.

 Open the catalog to page 1
PG750B Gas generator set-2

Engine Technical Data Governing Type: Governing Class: Compression Ratio Engine Electrical System: -Battery Charger Amps 32 Gross Engine Power: kW (hp) Fuel Systems Permitted Fuel: Natural gas with lower Fuel consumption varies widely within each gas type stated. This is because these gases ar available (naturally or produced) with variances in their physical properties. Radiator Cooling Airflow: m3/min (dm) External Restriction to Cooling Airflow Replaceable Element Cooling System Cooling System Capacity: I (US gal) Water Pump Type: Heat Rejected to Water & Heat Radiation to Room: kW(Btu/min...

 Open the catalog to page 2
PG750B Gas generator set-3

Alternator Physical Data Alternator Operating Data Insulation Class Winding Pitch Code: Ingress Protection Rating Excitation System: Voltage Regulation (steady state): Wave Form NEMA = TIF: Total Harmonic Content LL/LN: Radio Interference: Radiant Heat: kW(Btu/min) Suppression is in line with Performance Data: Data Item Motor Starting Short Circuit Reactances shown are applicable to baseload ratings * Based on 30% voltage dip at 0.6 power factor. ** With optional Permanent Magnet generator or AREP excitation. Voltage Technical Data

 Open the catalog to page 3
PG750B Gas generator set-4

General Information Documentation A full set of operation and maintenance manuals and circuit wiring diagrams, and commissioning/fault finding instruction leaflets. Generating Set Standards The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22. FG Wilson is a fully accredited ISO 9001 company. Warranty All equipment carries full manufacturer’s warranty. Extended warranty terms available. For details on warranty cover please contact your local dealer, or visit our website: www.FGWilson.com Dealer Contact Details: FG Wilson manufactures product in the...

 Open the catalog to page 4

All FG WILSON catalogs and technical brochures

  1. P7.5-4S

    4  Pages

  2. PG525B1

    4  Pages

  3. PG450B1

    4  Pages

  4. PG1250B2

    4  Pages

  5. PG375B3

    4  Pages

  6. PG345B3

    4  Pages

  7. Rental Range

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.