1. Catalogs
  2. FG WILSON
  3. P750-1 (681-750 kVA) Open Generator Set
video corpo

P750-1 (681-750 kVA) Open Generator Set

P750-1 (681-750 kVA) Open Generator Set

P750-1 (681-750 kVA) Open Generator Set

Product catalog summary
Prime Rating: This rating is for continuous electrical power supply at variable load, replacing commercially purchased power. It allows for 10% overload for 1 hour in every 12 hours without annual operation limits.
Standby Rating: Used for continuous power supply during utility power failures, with no overload permitted. The alternator is peak continuous rated as per ISO 8528-3.
Standard Reference Conditions: Conditions include 25°C air inlet temperature, 100m above sea level, and 30% relative humidity. Fuel consumption is based on diesel fuel with specific gravity of 0.85, conforming to BS2869: 1998, Class A2, EN590.
Output Ratings and Performance Data: The generator set is manufactured by FG Wilson with a Leroy Somer alternator. It operates at 480V, 60 Hz, with a prime power of 681.3 kVA and standby power of 750.0 kVA. The engine model is 2806A-E18TAG3.
Dimensions and Weights: The generator set measures 1132 mm in length, 139.6 mm in width, and 155.1 mm in height. The dry weight is 4264 kg, and the wet weight is 4332 kg.
Fuel Consumption: Fuel consumption varies with load, with specific data provided for 50% to 110% load at both 50 Hz and 60 Hz frequencies.
Available Options: FG Wilson offers various optional features, including sound attenuated enclosures, control panels, additional alarms, and exhaust silencers.
Exhaust System: Details include maximum allowable back pressure, exhaust gas flow, and temperature for both prime and standby modes.
Lubrication and Cooling Systems: The lubrication system includes an eco, full-flow oil filter with a total oil capacity of 68.5 liters. The cooling system is designed for ambient conditions up to 50°C.
Engine Specifications: The engine is a 6-cylinder, in-line, 4-stroke engine with a bore/stroke of 145.0/183.0 mm, turbocharged with air-to-air charge cooling.
Alternator Specifications: The alternator is manufactured by Leroy Somer, with an insulation class H, IP23 ingress protection, and AREP excitation system.
General Information: FG Wilson manufactures in multiple locations globally and operates through a global dealer network. Specifications are subject to change without notice.
See more

Catalog excerpts

P750-1 (681-750 kVA) Open Generator Set-1

P750-1 Image for illustration purposes only. Output Ratings Ratings and Performance Data Prime Voltage, Frequency Engine Make & Model: Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage. Alternator manufactured for FG Wilson by: Leroy Somer Alternator Model: Control Panel: Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2, EN590. Heavy Duty Fabricated Steel Circuit Breaker Type: Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Base Frame: Engine Speed: RPM Fuel Tank Capacity: Fuel Consumption: - Prime Available Options FG Wilson offer a range of optional features to tailor our generating sets to meet your power needs. Options include: A wide range of Sound Attenuated Enclosures A variety of generating set control and synchronising panels Additional alarms and shutdowns A selection of exhaust silencer noise levels For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit: www.FGWilson.com Dimensions and Weights Length (L) Wet = With Lube Oil and Coolant Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Generating set pictured may include optional accessories.

 Open the catalog to page 1
P750-1 (681-750 kVA) Open Generator Set-2

Engine Technical Data Combustion Air Flow: m³/min (cfm) Bore / Stroke: mm (in) Induction: Turbocharged Air To Air Charge Cooled Cooling Method: Governing Type: Governing Class: Max. Combustion Air Intate Restriction: kPa (in H2O) Compression Ratio: Cooling System Moment of Inertia: kg m² (lb/in²) Cooling System Capacity: l (US gal) Water Pump Type: Engine Electrical System: - Voltage / Ground - Battery Charger Amps Weight: kg (lb) Heat Rejected to Water & Lube Oil: - Prime Heat Radiation to Room: Heat radiated from engine and alternator - Prime Radiator Cooling Airflow: m³/min (cfm) External...

 Open the catalog to page 2
P750-1 (681-750 kVA) Open Generator Set-3

Alternator Physical Data Alternator Operating Data Leroy Somer Voltage Reguation: (Steady state) Wave Form NEMA = TIF: No. of Bearings: Insulation Class: Winding Pitch Code: Total Harmonic content LL/LN: Radio Interference: Suppression is in line with European Standard EN61000-6 Radiant Heat: kW (Btu/min) Ingress Protection Rating: Excitation System: Alternator Performance Data: Data Item Motor Starting Capability* kVA Short Circuit Capacity** % Reactances: Per Unit Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.6 power factor and AREP excitation system. **With...

 Open the catalog to page 3
P750-1 (681-750 kVA) Open Generator Set-4

General Information A full set of operation and maintenance manuals and circuit wiring diagrams. The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22. FG Wilson is a fully accredited ISO 9001 company. All prime equipment carries a one year manufacturer's warranty. Standby equipment, limited to 500 running hours per year, has a two year manufacturer's warranty. For details on warranty cover please contact your local Dealer, or visit our website: FGWilson.com. Dealer contact details: FG Wilson manufactures product in the following locations: Northern...

 Open the catalog to page 4

All FG WILSON catalogs and technical brochures

  1. P2250-3M

    6  Pages

  2. P7.5-4S

    6  Pages

Archived catalogs

  1. Rental Range

    7  Pages

  2. PG345B3

    4  Pages

  3. PG375B3

    4  Pages

  4. PG1250B2

    4  Pages

  5. PG450B1

    4  Pages

  6. PG525B1

    4  Pages

  7. P7.5-4S

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.