Prime and Standby Ratings: The document outlines two types of ratings for electrical power supply. The Prime Rating is for continuous power supply at variable loads, allowing for 10% overload for 1 hour in every 12 hours, with no annual operation limit. The Standby Rating is for power supply during utility failures, with no overload permitted, and the alternator is peak continuous rated as per ISO 8528-3.
Standard Reference Conditions: The standard conditions are set at 25°C air inlet temperature, 100m above sea level, and 30% relative humidity. Fuel consumption data is based on diesel fuel with specific gravity of 0.85, conforming to BS2869: 1998, Class A2.
Output Ratings and Performance Data: The generator set is powered by a Perkins 2206A-E13TAG5 engine and an alternator manufactured by Leroy Somer. It operates at 480V, 60 Hz, with a power output of 400.0 kVA (Prime) and 437.5 kVA (Standby). The control panel used is PowerWizard 1.1+.
Dimensions and Weights: The generator set dimensions are 3800 mm in length, 1131 mm in width, and 2156 mm in height. The dry weight is 3183 kg, and the wet weight is 3241 kg.
Fuel and Exhaust Systems: The fuel tank capacity is 888 liters. The exhaust system allows a maximum back pressure of 10.0 kPa, with exhaust gas flow and temperature data provided for both 50 Hz and 60 Hz operations.
Lubrication and Cooling Systems: The lubrication system uses API CH4 SAE15W-40 oil, with a total oil capacity of 45.2 liters. The cooling system has a capacity of 38.0 liters and uses a centrifugal water pump.
Engine Technical Data: The engine is a 6-cylinder, in-line, 4-stroke engine with a bore/stroke of 130.0/157.0 mm. It is turbocharged with air-to-air charge cooling and operates at 1800 rpm.
Alternator Data: The alternator is a Leroy Somer model LL6114B with IP23 ingress protection and SHUNT excitation system. It has a voltage regulation of +/- 0.5% and is compliant with EN61000-6 for radio interference suppression.
Standards and Warranty: The generating set complies with standards such as BS5000, ISO 8528, ISO 3046, IEC 60034, and NEMA MG-1.22. FG Wilson offers a one-year warranty for prime equipment and a two-year warranty for standby equipment, limited to 500 running hours per year.
Additional Options: FG Wilson provides various optional features, including CE certification upgrades, sound attenuated enclosures, control panels, additional alarms, and exhaust silencers.
See more

Catalog excerpts

P438-1 Generating Set-1

P438-1 Image for illustration purposes only. Output Ratings Ratings and Performance Data Prime Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage. Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Engine Make & Model: Alternator manufactured for FG Wilson by: Leroy Somer Alternator Model: Control Panel: Base Frame: Heavy Duty Fabricated Steel Circuit Breaker Type: Voltage, Frequency Engine Speed: RPM Fuel Tank Capacity: Fuel Consumption: l/hr (US gal/hr) - Prime Available Options FG Wilson offer a range of optional features to tailor our generating sets to meet your power needs. Options include: Upgrade to CE Certification A wide range of Sound Attenuated Enclosures A variety of generating set control and synchronising panels Additional alarms and shutdowns A selection of exhaust silencer noise levels For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit: www.FGWilson.com Dimensions and Weights Length (L) Wet = With Lube Oil and Coolant Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Generating set pictured may include optional accessories.

 Open the catalog to page 1
P438-1 Generating Set-2

Engine Technical Data Combustion Air Flow: m³/min (cfm) Bore / Stroke: mm (in) Induction: Turbocharged Air To Air Charge Cooled Cooling Method: Governing Type: Governing Class: Max. Combustion Air Intake Restriction: kPa (in H2O) Compression Ratio: Cooling System Moment of Inertia: kg m² (lb/in²) Cooling System Capacity: l (US gal) Water Pump Type: Engine Electrical System: - Voltage / Ground - Battery Charger Amps Weight: kg (lb) Heat Rejected to Water & Lube Oil: - Prime Heat Radiation to Room: Heat radiated from engine and alternator - Prime Radiator Cooling Airflow: m³/min (cfm) External...

 Open the catalog to page 2
P438-1 Generating Set-3

Alternator Physical Data Alternator Operating Data Leroy Somer Voltage Reguation: (Steady state) Wave Form NEMA = TIF: No. of Bearings: Insulation Class: Winding Pitch Code: Total Harmonic content LL/LN: Ingress Protection Rating: Radio Interference: Suppression is in line with European Standard EN61000-6 Radiant Heat: kW (Btu/min) Excitation System: Alternator Performance Data: Data Item Motor Starting Capability* kVA Short Circuit Capacity** % Reactances: Per Unit Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.6 power factor and SHUNT excitation. **With optional...

 Open the catalog to page 3
P438-1 Generating Set-4

General Information A full set of operation and maintenance manuals and circuit wiring diagrams. The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22. FG Wilson is a fully accredited ISO 9001 company. All prime equipment carries a one year manufacturer's warranty. Standby equipment, limited to 500 running hours per year, has a two year manufacturer's warranty. For details on warranty cover please contact your local Dealer, or visit our website: FGWilson.com. Dealer contact details: FG Wilson manufactures product in the following locations: Northern...

 Open the catalog to page 4

All FG WILSON catalogs and technical brochures

  1. P2250-3M

    6  Pages

  2. P7.5-4S

    6  Pages

Archived catalogs

  1. Rental Range

    7  Pages

  2. PG345B3

    4  Pages

  3. PG375B3

    4  Pages

  4. PG1250B2

    4  Pages

  5. PG450B1

    4  Pages

  6. PG525B1

    4  Pages

  7. P7.5-4S

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.