Product catalog summary
Prime and Standby Ratings: The document outlines two types of ratings for generator sets: Prime and Standby. Prime ratings are for continuous power supply at variable loads without annual operation limits, allowing a 10% overload for 1 hour in 12 hours. Standby ratings are for power supply during utility failures, with no overload permitted, and the alternator is peak continuous rated as per ISO 8528-3.
Standard Reference Conditions: The standard conditions include an air inlet temperature of 25°C (77°F), altitude of 100m (328 ft) A.S.L., and 30% relative humidity. Fuel consumption data is based on diesel fuel with a specific gravity of 0.85, conforming to BS2869: 1998, Class A2.
Output Ratings and Performance Data: The generator set is manufactured by FG Wilson with an alternator by Leroy Somer. It includes specifications for voltage, frequency, engine make and model, control panel, circuit breaker type, engine speed, and base frame. The document provides detailed dimensions and weights for both dry and wet conditions.
Fuel Consumption: Fuel consumption is detailed for various load percentages at both 50 Hz and 60 Hz frequencies, based on diesel fuel specifications.
Available Options: FG Wilson offers optional features such as CE Certification upgrades, sound attenuated enclosures, control and synchronizing panels, additional alarms, and exhaust silencer noise levels.
Technical Data: Detailed technical data is provided for the engine, lubrication system, cooling system, and alternator. This includes information on oil capacity, cooling methods, heat rejection, and airflow requirements.
Generator Set Standards: The equipment complies with standards such as BS5000, ISO 8528, ISO 3046, IEC 60034, and NEMA MG-1.22. FG Wilson is ISO 9001 accredited.
Warranty: Prime equipment has a one-year warranty, while standby equipment has a two-year warranty limited to 500 running hours per year.
General Information: FG Wilson operates globally with manufacturing locations in Northern Ireland, Brazil, China, India, and the USA. The document emphasizes the company's policy of continuous product development and the availability of operation and maintenance manuals.
See more

Catalog excerpts

P2250-1/P2250-1E -- 2250 kVA Open Generator Set-1

P2250-1/P2250-1E Image for illustration purposes only. Output Ratings Ratings and Performance Data Voltage, Frequency Engine Make & Model: Alternator manufactured for FG Wilson by: Leroy Somer Alternator Model: Ratings at 0.8 power factor. Control Panel: Please refer to the output ratings technical data section for specific generator set outputs per voltage. Base Frame: Heavy Duty Fabricated Steel Circuit Breaker Type: Frequency: Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Fuel Tank Capacity: Fuel Consumption: l/hr (US gal/hr) - Prime 418.1 (110.5) Available Options FG Wilson offer a range of optional features to tailor our generator sets to meet your power needs. Options include: Upgrade to CE Certification A wide range of Sound Attenuated Enclosures A variety of generator set control and synchronising panels Additional alarms and shutdowns A selection of exhaust silencer noise levels For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit: www.FGWilson.com Dimensions and Weights Length (L) Wet = With Lube Oil and Coolant Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Generator set pictured may include optional accessories.

 Open the catalog to page 1
P2250-1/P2250-1E -- 2250 kVA Open Generator Set-2

Engine Technical Data Replaceable Element Combustion Air Flow: m³/min (cfm) 160.0 (6.3)/190.0 (7.5) Turbocharged Air To Water Charge Cooled Cooling Method: Governing Type: Governing Class: Max. Combustion Air Intake Restriction: kPa (in H2O) Compression Ratio: Cooling System Moment of Inertia: kg m² (lb/in²) Cooling System Capacity: l (US gal) Water Pump Type: Engine Electrical System: - Voltage / Ground Heat Rejected to Water & Lube Oil: - Battery Charger Amps Heat Radiation to Room: Heat radiated from engine and alternator - Prime 202.9 (11539) - Standby 225.6 (12830) Radiator Fan Load: kW...

 Open the catalog to page 2
P2250-1/P2250-1E -- 2250 kVA Open Generator Set-3

Alternator Physical Data Alternator Operating Data Leroy Somer Voltage Regulation: (Steady state) Wave Form NEMA = TIF: No. of Bearings: Insulation Class: Winding Pitch Code: Total Harmonic content LL/LN: Radio Interference: Suppression is in line with European Standard EN61000-6 Radiant Heat: kW (Btu/min) Ingress Protection Rating: Excitation System: Alternator Performance Data: Data Item Motor Starting Capability* kVA Short Circuit Capacity** % Reactances: Per Unit Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.4 power factor . **With optional permanent magnet...

 Open the catalog to page 3
P2250-1/P2250-1E -- 2250 kVA Open Generator Set-4

General Information Documentation A full set of operation and maintenance manuals and circuit wiring diagrams. Generator Set Standards The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22. FG Wilson is a fully accredited ISO 9001 company. Warranty All prime equipment carries a one year manufacturer's warranty. Standby equipment, limited to 500 running hours per year, has a two year manufacturer's warranty. For details on warranty cover please contact your local Dealer, or visit our website: FGWilson.com. Dealer contact details: FG Wilson manufactures...

 Open the catalog to page 4

All FG WILSON catalogs and technical brochures

  1. P2250-3M

    6  Pages

  2. P7.5-4S

    6  Pages

Archived catalogs

  1. Rental Range

    7  Pages

  2. PG345B3

    4  Pages

  3. PG375B3

    4  Pages

  4. PG1250B2

    4  Pages

  5. PG450B1

    4  Pages

  6. PG525B1

    4  Pages

  7. P7.5-4S

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.