www.FGWilson.com P2000/P2200E Image for illustration purposes only. Output Ratings Ratings and Performance Data Generating Set Model Standby* - / - - / - Ratings at 0.8 power factor. Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Perkins 4016TAG2A Alternator manufactured for FG Wilson by: Leroy Somer Alternator Model: LL9124H Control Panel: PowerWizard 1.1+ Heavy Duty Fabricated Steel Circuit Breaker Type: 2000.0 kVA / 1600.0 kW 2200.0 kVA / 1760.0 kW Engine Make & Model: Base Frame: 380-415V,50Hz Prime* 3 Pole ACB Frequency: 50 Hz 60 Hz Engine Speed: RPM 1500 - Fuel Tank Capacity: - litres (US gal) Fuel Consumption: l/hr (US gal/hr) - Prime 423.5 (111.9) - - Standby 474.1 (125.2) - (100% Load) Available Options FG Wilson offer a range of optional features to tailor our generating sets to meet your power needs. Options include: Upgrade to CE Certification A wide range of Sound Attenuated Enclosures A variety of generating set control and synchronising panels Additional alarms and shutdowns A selection of exhaust silencer noise levels For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit: www.FGWilson.com Dimensions and Weights Length (L) Width (W) Height (H) Dry Wet mm (in) mm (in) mm (in) kg (lb) kg (lb) 5749 (226.3) 2300 (90.6) 3020 (118.9) 15495 (3416115695 (34602 Dry = With Lube Oil Wet = With Lube Oil and Coolant Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1/22. Generating set pictured may include optional accessories. FG Wilson has manufacturing facilities in the following locations: Northern Ireland • Brazil • China • India • USA With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network. To contact your local Sales Office please visit the FG Wilson website at www.FGWilson.com
Open the catalog to page ١Engine Technical Data 50 Hz Air Systems No. of Cylinders / Alignment: 16 / Vee 4 Stroke Cycle: Air Filter Type: 60 Hz Combustion Air Flow: m³/min (cfm) Bore / Stroke: mm (in) Turbocharged Air To Air Charge Cooled - Prime 137.0 (4838) - - Standby 145.0 (5121) - 160.0 (6.3)/190.0 (7.5) Induction: Replaceable Element Cooling Method: Water Governing Type: 3.7 (14.9) - 50 Hz 60 Hz 355.0 (93.8) - Electronic Governing Class: Max. Combustion Air Intate Restriction: kPa (in H2O) ISO 8528 G2 Compression Ratio: 13.6:1 Cooling System Displacement: l (cu. in) 61.1 (3730.0) Moment of Inertia: kg m²...
Open the catalog to page ٢Alternator Physical Data Alternator Operating Data Insulation Class: Winding Pitch Code: Ingress Protection Rating: Excitation System: Leroy Somer Voltage Reguation: (Steady state) Wave Form NEMA = TIF: Total Harmonic content LL/LN: Radio Interference: Radiant Heat: kW(Btu/min) Suppression is in line with European Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.6 power factor. **With optional permanent magnet generator or AREP excitation.
Open the catalog to page ٣General Information Documentation A full set of operation and maintenance manuals and circuit wiring diagrams. Generating Set Standards The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22. FG Wilson is a fully accredited ISO 9001 company. Warranty All prime equipment carries a one year manufacturer's warranty. Standby equipment, limited to 500 running hours per year, has a two year manufacturer's warranty. For details on warranty cover please contact your local Dealer, or visit our website: FGWilson.com. Dealer contact details: FG Wilson has...
Open the catalog to page ٤All FG WILSON catalogs and technical brochures
-
FG Wilson Control Systems
24 Pages
-
P2000P1/P2000E1
4 Pages
-
Product Rating Summary
15 Pages
-
P688-1 Diesel Generator Set
4 Pages
-
P605-1 Diesel Generating Set
4 Pages
-
P625-1 Diesel Generator Set
4 Pages
-
P500-1 Diesel Generator Set
4 Pages
-
P22-6 Diesel Generator Set
4 Pages
-
P18-6 Diesel Generator Set
4 Pages
-
9.5-4 Diesel Generator Set
4 Pages
-
P14-6S Diesel Generator Set
4 Pages
-
P11-6S Diesel Generator Set
4 Pages
-
P7.5-4S
4 Pages
-
30-220 kVA CAL CALG
3 Pages
-
24 - 220 kVA Range Brochure
20 Pages
-
6.8 - 22 kVA CAL Enclosure
4 Pages
-
350 - 750 kVA Range Brochure
16 Pages
-
6.8 - 22 kVA Range Brochure
16 Pages
-
32 - 200 kVA Range Brochure
12 Pages
-
P400-1 Open Generator Set
4 Pages
-
P438-1 Generating Set
4 Pages
-
450-550 kVA Enclosures
2 Pages
-
24 - 220 kVA CAE Enclosure
4 Pages
-
30 - 220 kVA CAE Enclosure
3 Pages
-
350-750 kVA Enclosures
4 Pages
-
Control Panel Range
24 Pages
-
Secure Mini Container
2 Pages
-
Rental Power Module
2 Pages
-
Rental Back Synch Brochure
3 Pages
-
PG620B1 Gas Generator Set
4 Pages
-
PG750B Gas generator set
4 Pages
-
PG525B1
4 Pages
-
PG450B1
4 Pages
-
PG1250B2
4 Pages
-
PG375B3
4 Pages
-
PG345B3
4 Pages
-
26 - 220 kVA Range Brochure
16 Pages
-
350-750 kVA Range Brochure
16 Pages
-
5.5 - 22 kVA Range Brochure
20 Pages
-
2500 kVA Open Generator Set
4 Pages
-
Rental Range
7 Pages
-
455 - 750 kVA Range
16 Pages
-
The 26 - 200 kVA Range
16 Pages
-
Back Sync Control System
3 Pages
-
Rental Power Module
2 Pages
-
Secure Mini Container
2 Pages
-
easYgen Control Panels
4 Pages