Catalog excerpts
P1825/P2000E Image for illustration purposes only. Output Ratings Ratings and Performance Data Voltage, Frequency Engine Make & Model: Alternator manufactured for FG Wilson by: Leroy Somer Alternator Model: Ratings at 0.8 power factor. Control Panel: Please refer to the output ratings technical data section for specific generator set outputs per voltage. Base Frame: Heavy Duty Fabricated Steel Circuit Breaker Type: Frequency: Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Fuel Tank Capacity: Fuel Consumption: l/hr (US gal/hr) - Prime 378.2 (99.9) Available Options FG Wilson offer a range of optional features to tailor our generator sets to meet your power needs. Options include: Upgrade to CE Certification A wide range of Sound Attenuated Enclosures A variety of generator set control and synchronising panels Additional alarms and shutdowns A selection of exhaust silencer noise levels For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit: www.FGWilson.com Dimensions and Weights Length (L) Wet = With Lube Oil and Coolant Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Generator set pictured may include optional accessories.
Open the catalog to page 1Engine Technical Data Combustion Air Flow: m³/min (cfm) Turbocharged Air To Air Charge Cooled Replaceable Element Cooling Method: Governing Type: Governing Class: Max. Combustion Air Intake Restriction: kPa (in H2O) Compression Ratio: Cooling System Moment of Inertia: kg m² (lb/in²) Cooling System Capacity: l (US gal) Water Pump Type: Engine Electrical System: - Voltage / Ground - Battery Charger Amps Weight: kg (lb) Heat Rejected to Water & Lube Oil: - Prime 586.0 (33325) Heat Radiation to Room: Heat radiated from engine and alternator - Prime 171.2 (9736) - Standby 185.0 (10521) Radiator...
Open the catalog to page 2Alternator Physical Data Alternator Operating Data Insulation Class: Winding Pitch Code: Ingress Protection Rating: Excitation System: Leroy Somer Voltage Regulation: (Steady state) Wave Form NEMA = TIF: Total Harmonic content LL/LN: Radio Interference: Radiant Heat: kW (Btu/min) Suppression is in line with European Performance Data: Motor Starting Short Circuit Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.4 power factor. **With optional permanent magnet generator.
Open the catalog to page 3General Information A full set of operation and maintenance manuals and circuit wiring diagrams. The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22. FG Wilson is a fully accredited ISO 9001 company. All prime equipment carries a one year manufacturer's warranty with unlimited hours or two year manufacturer's warranty limited to 6,000 running hours. Standby equipment, limited to 500 running hours per year, has a three year manufacturer's warranty. Dealer contact details: FG Wilson manufactures product in the following locations: Northern Ireland...
Open the catalog to page 4All FG WILSON catalogs and technical brochures
-
FG Wilson Control Systems
24 Pages
-
P2000P1/P2000E1
4 Pages
-
Product Rating Summary
15 Pages
-
P688-1 Diesel Generator Set
4 Pages
-
P605-1 Diesel Generating Set
4 Pages
-
P625-1 Diesel Generator Set
4 Pages
-
P500-1 Diesel Generator Set
4 Pages
-
P22-6 Diesel Generator Set
4 Pages
-
P18-6 Diesel Generator Set
4 Pages
-
9.5-4 Diesel Generator Set
4 Pages
-
P14-6S Diesel Generator Set
4 Pages
-
P11-6S Diesel Generator Set
4 Pages
-
P7.5-4S
4 Pages
-
30-220 kVA CAL CALG
3 Pages
-
24 - 220 kVA Range Brochure
20 Pages
-
6.8 - 22 kVA CAL Enclosure
4 Pages
-
350 - 750 kVA Range Brochure
16 Pages
-
6.8 - 22 kVA Range Brochure
16 Pages
-
32 - 200 kVA Range Brochure
12 Pages
-
P400-1 Open Generator Set
4 Pages
-
P438-1 Generating Set
4 Pages
-
450-550 kVA Enclosures
2 Pages
-
24 - 220 kVA CAE Enclosure
4 Pages
-
30 - 220 kVA CAE Enclosure
3 Pages
-
350-750 kVA Enclosures
4 Pages
-
Control Panel Range
24 Pages
-
Secure Mini Container
2 Pages
-
Rental Power Module
2 Pages
-
Rental Back Synch Brochure
3 Pages
-
PG620B1 Gas Generator Set
4 Pages
-
PG750B Gas generator set
4 Pages
-
PG525B1
4 Pages
-
PG450B1
4 Pages
-
PG1250B2
4 Pages
-
PG375B3
4 Pages
-
PG345B3
4 Pages
-
26 - 220 kVA Range Brochure
16 Pages
-
350-750 kVA Range Brochure
16 Pages
-
5.5 - 22 kVA Range Brochure
20 Pages
-
2500 kVA Open Generator Set
4 Pages
-
Rental Range
7 Pages
-
455 - 750 kVA Range
16 Pages
-
The 26 - 200 kVA Range
16 Pages
-
Back Sync Control System
3 Pages
-
Rental Power Module
2 Pages
-
Secure Mini Container
2 Pages
-
easYgen Control Panels
4 Pages