Pipetting System Overview

The Festo pipetting system with the DHOE pipette head is designed for high flexibility and precision. It can handle volumes as small as 1 µl with a precision of less than 5%, making it suitable for various applications. The system allows for adjustable pipetting speeds up to 10 ml/s and can adapt to different viscosities during the pipetting process.

Compatibility and Integration

The system is compatible with microwell plates of 96, 384, and 1536 wells, and integrates easily with other Festo automation solutions. It features an open and flexible design, allowing for easy configuration and extension. The pipette head is media-resistant and supports a range of tip sizes that are chemically resistant.

Process Reliability

The system includes integrated monitoring functions to ensure correct pipetting volumes and quickly detect issues such as obstructions or air interruptions. It supports precise actuation and easy integration with kinematics and handling systems, ensuring accurate positioning of the pipette head.

Technical Specifications

  • Pipetting volume range: 1 µl to 25 ml
  • Pipetting throughput: Up to 10 ml/s
  • Pipetting accuracy: <5% CV for volumes under 5 µl, <2% CV for volumes under 50 µl, <1% CV for volumes under 500 µl, <0.5% for volumes under 1000 µl
  • Pressure supply: −0.2 to 0.65 bar
  • Power supply: 24 V DC (2 W)
  • Dimensions: 8.1 x 76.2 x 30 mm
  • Grid: 9 mm, suitable for microwell plates
  • Pipette tip volumes: 20, 300, 1000 µl
  • Pipette tip features: Filter, sterile
  • Pipette tip force: <10 N per tip

Additional Features

The system includes components such as the pressure and vacuum generator PGVA, fork light barrier SOOF, flow sensor SFAH, and valve control module VAEM for enhanced functionality. The pipette tip ejector DHAO-EJ allows for mechanical removal and disposal of used tips.

See more

Catalog excerpts

Pipetting system with pipette head DHOE-1

Pipetting system with pipette head DHOE Highly flexible! Highlights • Open pipetting system • Freely configurable • Flexible extension options • Media-resistant pipette head • With pipette tips • Easy integration • Complete solution from a single source The open pipetting system for the easy transport of liquids fits your needs as it is very easy to configure and extremely flexible. The system is compatible with a range of tip sizes, which are highly resistant to chemicals and suitable for a wide range of different viscosities. Even minute volumes as small as 1 µl can be pipetted with the greatest precision. Pipette head: precise and adaptable The precision of <5% for volumes as small as 1 µl is sufficient for many pipetting applications. The pipetting speed can be individually varied to up to 10 ml/s and be adapted to different viscosities, even during the pipetting process. The 9 mm pitch is suitable for microwell plates with 96 wells as well as for those with 384 and 1536 wells in combination with other automation solutions from Festo. Reliable processes built in Controlling the complete pipetting process is central to the design of the systems. With this pipetting system you can implement all the important process elements, and in addition detect fill levels or track the handling of the pipette tips. We also offer an integrated monitoring function for the pipetting process to ensure the correct pipetting volume at all times. It allows you to detect obstructions due to particles or interrupted aspiration caused by air very quickly – and take appropriate action.

 Open the catalog to page 1
Pipetting system with pipette head DHOE-2

Pipetting system with pipette head DHOE Open and flexible system: the individual components and their functions Easy system integration Easy integration with kinematics/ handling systems like the planar surface gantry EXCM or electric linear drives EGSC ensures precise posi tioning of the pipette head. The combination of rotary gripper module EHMD and parallel gripper EHPS is ideally suited to opening sample containers. The pipette head DHOE can transport the most minute pipetting volumes as small as 1 µl with outstanding precision. On-board supply The valve control module VAEM delivers total...

 Open the catalog to page 2

All FESTO catalogs and technical brochures

  1. MCS®

    52  Pages

  2. VZDB

    12  Pages

  3. VLX

    6  Pages

  4. KVZA

    10  Pages

  5. VZPR

    38  Pages

  6. VZBM

    39  Pages

  7. KVZB

    10  Pages

  8. VZWP

    8  Pages

  9. VYKB

    14  Pages

  10. VYKA

    14  Pages

  11. VZWM-L

    9  Pages

  12. VZWF

    12  Pages

  13. VZWD

    19  Pages

  14. VZQA

    19  Pages

  15. VZXF

    34  Pages

  16. VZBF

    26  Pages

  17. VZBD

    57  Pages

  18. VZBC

    57  Pages

  19. VZBA

    57  Pages

  20. VAPB

    57  Pages

  21. VZBE

    42  Pages

  22. KDFP

    3  Pages

  23. DFPD-HD

    42  Pages

  24. DAPS

    72  Pages

  25. DFPD

    39  Pages

  26. DLP

    12  Pages

  27. VZXA

    44  Pages

  28. DFPI

    40  Pages

  29. DFPC

    16  Pages

  30. CMSH

    17  Pages

  31. CMSX

    16  Pages

  32. DAPZ

    6  Pages

  33. SRAP

    10  Pages

  34. SRBI

    10  Pages

  35. SRBG

    20  Pages

  36. SRBE

    18  Pages

  37. SRBC

    27  Pages

  38. VOFD

    37  Pages

  39. VOFC

    55  Pages

  40. VSNC-G1/8

    19  Pages

  41. VSNC

    92  Pages

  42. VTSA-MP

    2  Pages

  43. Silencers

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.