video corpo cad

Modular electrical peripherals, for type 03/04
85Pages

{{requestButtons}}

Catalog excerpts

Modular electrical peripherals, for type 03/04 - 1

Modular electrical peripherals, for type 03/04

Open the catalog to page 1
Modular electrical peripherals, for type 03/04 - 2

U- Typediscontinued Available up until 2017 Modular electrical peripherals, for type 03/04 festd Key features Innovative First modular valve terminal on the market with modular electrical peխripherals Standardised from the individual midi valve up to multi-pin and fieldbus connections Օ First programmable valve terminal with integrated controller Digital I/O modules, either PNP switching Օ Analogue I/O in the field for short lines Special modules for control desks Օ Interfaces for subordinate, decen-tralised installation systems Modular Modular system offering a range of configuration...

Open the catalog to page 2
Modular electrical peripherals, for type 03/04 - 3

L- Typediscontinued Available up until 2017 Modular electrical peripherals, for type 03/04 Key features -estd Modular electrical peripherals for valve Modular electrical peripherals provide the required control technology for type 03 (MIDI/MAXI) and type 04 (ISO) valve terminals. Together these com-ponents form the most comprehensive system range in intelligent pneu-matics and also offer the advantage of asturdy metal design. terminal type 03/04 As well as incorporating protection class IP65, the system also provides benefits through the sturdy design of its modules and connections....

Open the catalog to page 3
Modular electrical peripherals, for type 03/04 - 4

U- Typediscontinued Available up until 2017 Modular electrical peripherals, for type 03/04 Keyfeatures - General festd Performance characteristics Control block, fieldbus connection, multi-pin connection Optimisingand extending applications: Modules for installation-saving connection usingsturdySub-D plugs in IP65 Օ Low-cost connections to input/ output stations and control units CP modules for connectingdecen-tralised CPVand CPAvalve terminals Օ Extensions and supplements can be added atanytime Easy mounting: On H-rail Օ On mountingsurface Withcovers in welding environments Simple...

Open the catalog to page 4
Modular electrical peripherals, for type 03/04 - 5

U- Typediscontinued Available up until 2017 Modular electrical peripherals, for type 03/04 Keyfeatures - General ■estd Type 03 - MIDI/MAXI valve terminais Type 04 - ISO valve terminais General fonctions of the bus nodes and A bus node or control block is at the heart of the modular electrical periph-eral system. They manage the communication connection to higher-order controllers and master interͭfaces and a PLC program with a full range of additional functions is ex-ecuted directly in the control block. The power supply for the I/O modules and the sensors connected to them is provided by...

Open the catalog to page 5
Modular electrical peripherals, for type 03/04 - 6

L- Typediscontinued Available up until 2017 Modular electrical peripherals, for type 03/04 Key features - Electrical components festd Supply voltage The entire power supply for the system and the sensors and actuators con-nected to it is provided via an M18 mains plug. The power supply for the electrical peripherals type 03 and 04 is split in two. Pin 1 of the mains plug provides the sensor supply for the input modules and supplies the internal electronics of the individual modules. The sensor supply is protected separ-ately from the electronics supply in thenodeby means of a 2 A fuse. We...

Open the catalog to page 6
Modular electrical peripherals, for type 03/04 - 7

U- Typediscontinued Available up until 2017 Modular electrical peripherals, for type 03/04 festd Key features - Diagnosis Diagnostic information Description Function Short circuit/overload at output Output has short-circuited or become overloaded Monitors the electrical outputs of the output modules Vvalves < 21.6 V DC Load voltage at pin 2 (valves and outputs) of the operating voltage connection < 21.6 V DC Monitors the tolerance of the load voltage forvalves and electrical outputs Voutputs < 10 V DC Load voltage at pin 2 (valves and outputs) of the operating voltage connection < 10 V DC...

Open the catalog to page 7
Modular electrical peripherals, for type 03/04 - 8

U- Typediscontinued Available up until 2017 Modular electrical peripherals, for type 03/04 festd Key features - I/O addressing General guidelines on I/O addressing A maximum of 12 electrical modules can be assembled. Note, however, that some modules occupy 2 or even 3 module positions, in which case the maximum numberof modules that can be assembled is reduced. All 12 module positions can generally be used as inputs or outputs, however there are various fieldbus-specific restrictions that are documented in the node description. The number and type of inputs/out-puts, and hence input/output...

Open the catalog to page 8
Modular electrical peripherals, for type 03/04 - 9

U- Typediscontinued Available up until 2017 Modular electrical peripherals, for type 03/04 Peripherals overview - Fieldbus Systems -estd Fieldbus Systems, programmable terminal groups SIEMENS DviCfi뻻t-ASA Fieldbus variations: Of the more than 20 different fieldbus systems (protocols) available in the market, some have emerged as the most important variants. Festo supports these by means of various fieldͭbus nodes (FBxx) on its valve terminals. Fieldbus systems require a powerful, central PLC and a master inͭterface adapted to that particular fieldbus. Fieldbus systems are generally used...

Open the catalog to page 9
Modular electrical peripherals, for type 03/04 - 10

U- Typediscontinued Available up until 2017 Modular electrical peripherals, for type 03/04 Peripherals overview - Control blocks festd Control blocks Integrated controllers in the Festo valve terminals permit the construction of stand-alone control units to IP65 -without control cabinets. Using the slave operation mode, these With the master operation mode, ter-valve terminals can be used for intelli- minal groups can be designed with gent pre-processingand are therefore many options and functions, which ideal modules for designing decentra- can autonomously control a medium lised...

Open the catalog to page 10
Modular electrical peripherals, for type 03/04 - 11

U- Typediscontinued Available up until 2017 Modular electrical peripherals for type 03/04 can be equipped with bus node. In addition to controlling the valves and electrical outputs, corre-spondingsensorfeedback can bere-corded at the electrical peripherals and transmitted via the fieldbus to the control cabinet. The followingapplies to bus nodes: Max. 26 valve solenoid coils Օ Numberof inputs dependenton fieldbus type Numberof electrical outputs de-pendenton fieldbus type and number ofpneumatic valves Օ Status bits for program controlled diagnosis occupy4 inputbits - Undervoltage...

Open the catalog to page 11

All Festo catalogs and technical brochures

  1. DSBC

    58 Pages

  2. Silencers

    15 Pages

  3. Silencers U

    4 Pages

  4. Lubricators MS

    11 Pages

  5. Checkbox CHB

    23 Pages

  6. Air guns

    7 Pages