Underground single wall tanks - 1

UNDERGROUND SINGLE WALL TANKS Destination - Irrigation plants, fire protection plants, drinking water storage, storage of fertilizers and chemical products for the agricultural sector Quality and safety The latest technologies for the production of tanks based on years of experience and qualifications of the staff engaged in the production process from the engineering department, through logistics, quality control and production, ensure the finest quality of tanks and the safely of storing harmful and hazardous substances for humans and environment. Design and manufacture under the control of notified bodies The technical documentation of tanks, production processes and the final acceptance of tanks are agreed, accepted and approved by the Office of Technical Inspection (UDT) as well as other notified bodies. Our tanks hold certificates of approval issued by offices like the Chief Office for Measurements (GUM) to ensure that they comply with the applicable requirements of metrology standards.

Open the catalog to page 1
Underground single wall tanks - 2

The range of tank diameters From 1 m to 4 m The range of tank capacity From 1 m3 to 220 m3 The number and capacity of chambers depending on technical possibilities From 1 to 8 chambers Made in accordance with EN 12285-1, DIN 6608 or WUDT/UC/2003. Material is certified carbon steel S235JR. Preparation of the external surface of tank sheets, grit blasting with the cleanliness degree of Sa 2.5 according to PN-1SO 8501-1. Polyurethane topcoat ENDOPRENE ensuring resistance to electric breakdown up to 14kV. Tanks can be provided with the additional internal surface security by using special...

Open the catalog to page 2
Underground single wall tanks - 3

Nominal capacity

Open the catalog to page 3
Underground single wall tanks - 4

Standard equipment of tank: - DN600 manhole with a gasket per chamber - DN50 or DN40 suction hose up to 8 pcs per chamber -1 pc of DN 50 ventilation valve per chamber -1 pc of DN40 drainage pipe per chamber - DN100 or DN80 deluge pipe ended with a collar, with a flow hydraulic trap and a certified overfill protection valve per chamber - DN50 manual measuring pipes with a lengthening pipe and Camlok per chamber - Electronic measuring pipe with a lengthening pipe and Camlok per chamber LAG2000 Leak detection control device Cover with a concrete frame (400 - Control and measuring systems -...

Open the catalog to page 4

All Ferrero S.p.A. catalogs and technical brochures