Tubular heaters
12Pages

{{requestButtons}}

Catalog excerpts

Tubular heaters - 1

RfcSISTfcNZe: TUBOLARI PfcR ARIA - ACQUA - OLIO - PIASTRE: CAl_D6= RESISTANCES BUNDES ROUR AIR - EAU - HUIL-E - BUOOUES CHAUOES

Open the catalog to page 1
Tubular heaters - 2

APPUCA^IONI TIPICHfe MOST POPULAR APPLICATIONS APPLICATIONS LaS PLUS COURANTS 3.- ARIA, GAS INERT! - AIR, INERT GASES - AIR, GAZINERTE 4.- PIASTRE METALQCHE - METAL PLATENS - BLOQUES CHAUDES

Open the catalog to page 2
Tubular heaters - 3

r>Cc3Hrx3 tsnd control t^cnnolocjij RISCAUDATORI SU TAPPO F-ILErTTATO TUBULAR HE=ATE=R£a F-OR WATER / OIL R£=E>IE>TANCE:E> BUNDE=E> POUR E=AU / HUlUfc

Open the catalog to page 3
Tubular heaters - 5

E=E>E=CU^IONI E>RE=CIAU SR&CIAL £=X£=OUTIONED IP55 PROTECTION CAP WITH BUILT-IN SINGLE PHASE THERMOSTAT AVEC SEUL THERMOSTAT SP&CIF-ICH& COSTRUTTIVE: & TOLL&RANZ& TECHNICAL D&TAILS AND TOLERANCtb RESISTENZA - RESISTANCE - RESISTANCE [Q] +/-10% RIGIDITA' DIELETTRICA- RIGIDITE' DIELECTRIQUE - DIELECTRIC STRENGTH 1500 V RESISTENZA D'ISOLAMENTO - RESISTANCE D'ISOLEMENT - INSULATION RESISTANCE >200 MQ/1000V CORRENTEDI FUGA - COURANT DE FUITE- LEAKAGE CURRENT <0.1 Ma TAPPO FILETTATO IN OTTONE - A RICHIESTA IN ACCIAIO INOX THREADED BRASS CAP- UPON REQUEST MADE OF STAINLESS STEEL BOUCHON FILETE' EN...

Open the catalog to page 5
Tubular heaters - 6

iT^tsMoq dnd control t^cnnoloQij Re=SE>TE=NZE= TUBOLARI ALfcTTATG: PE=R ARIA GrLGrMGrNTS) BLINDGrS A All_GrTTGrE> E>PIRAl_E=E=E> POUR AIR F-INN&D TUBULAR HfcATGiREa FOR AIR BOCCOLA AGGRAFFATA BUISSON SERTISSEUSE CRIMPED BUSH

Open the catalog to page 6
Tubular heaters - 7

BOCCOLA AGGRAFFATA BUISSON SERTISSEUSE CRIMPED BUSH BOCCOLA BRASATA BUISSON BRAISE' WELDED BUSH TECHNICAL DfcTAILS AND TOLtRANCtS RIGIDITA' DIELETTRICA - RIGIDITE' DIELECTRIQUE - DIELECTRIC STRENGTH 1500 V RESISTENZA D ISOLAMENTO - RESISTANCE D'ISOLEMENT - INSULATION RESISTANCE >200 M£}/1000V CORRENTE Dl FUGA - COURANT DE FUITE - LEAKAGE CURRENT <0.1 Ma

Open the catalog to page 7
Tubular heaters - 8

Le resistenze tubolari FEPASrl sono in grado di assicurare flessibilita di applicazione, alte performances, massimi standard di sicurezza. L'ampia gamma di modelli in termini di lunghezze standard, potenze, sezioni, permette di ottimizzare la soluzione delle richieste all'interno del nostra range di prodotti. FEPA Sri tubular heaters are able to assure high performances, application flexibility, perfect safety standard. The large range of items in terms of standard lengths, wattages, cross sections, allows to find the best solution for all applications within FEPA products. FEPA Sri...

Open the catalog to page 8
Tubular heaters - 9

SP6CIFICHE TECNICHE - CONSTRUCTIVE SPECIFICATIONS - SPECIFICATIONS TECHNIQUES POTENZA - WATTAGE - PUISSANCE [W] - TOLERANCE +5% -10% LUNGHEZZA - LENGTH - LONGEUR [mm] - TOLERANCE +2% -2% RIGIDITA DIELETTRICA - DIELECTRIC STRENGTH - RIGIDITE' DIELECTRIQUE [V] 1500 ISOLAMENTO - INSULATION RESISTANCE - RESISTANCE D'ISOLEMENT [ohm] > 10M CORRENTE Dl FUGA - LEAKAGE CURRENT - COURANT DE FUITE [mA] < 0,1 TEMP. MAX SULLA GUAINA - MAX TEMP. ON SHEATH - TEMP. MAX SUR LA GAINE [°C] 750 MATERIALE - MATERIAL - MATERIEL AISI 321 RAGGIO MINIMO CURVATURA - MIN. BENDING RADIUS - RAYON MINIMUM DE COURBURE...

Open the catalog to page 9
Tubular heaters - 10

iT^tsMoq dnd control t^cnnoloQij RE=£DI£DTE=N^E= TUBOL.ARI MORBID£= TUBULAR H&AT&RS &ASY TO BEzND RESISTANCE: BUND£=E=E> F-ORMABL.£■ A F-ROID CARATTfcRfeTICHfc TfcCNCHfc T&CHNKZAL. F^ATUR&S Corpo in acciaio inox flessibile - Flexible stainless steel sheath - Corp en acier inoxydable Lunghezza massima 2700 mm - Maximum Length 2700 mm - Longeur maximale 2700 mm Diametro standard 8.5mm - Standard diameter Potenza specifica di 15W/cm2 - Watt Density Temp, max di utilizzo 700°C - Max working temp. 700°C - Temp, max d'emploi 700°C Raggio min. di curvatura 10mm - Mln. bending radius 10mm - Rayon...

Open the catalog to page 10
Tubular heaters - 11

iT^tsMoq dnd control t^cnnoloQLj RG=SISTE=NZE: TUBOLARI £>PZ. bxM mm Le resistenze TeraFir sono i riscaldatori tubolari applicati ai sistemi a canale caldo. TeraFir tubular heaters are installed on hot runner systems. Les resistances tubulaires TeraFir sont appliques sur les systemes a canaux chauds. Caratteristiche Tecniche - Technical Features - Specifications Techniques Sezione - Cross Section - Section Tensione di alimentazione - Supply Voltage - Tension d'emploi Rigidita dielettrica - Dielectric Strength - Rigidite Dielectrique Resistenza Isolamento - Insulation Resistance - Resistance...

Open the catalog to page 11
Tubular heaters - 12

ITALY - SW£D£N - HNLAND - SPAIN POLAND - BUL.OARIA - SLOVAKIA ROMANIA - CZEzCH REzPUBUC CHINA - ISRAEL. - LEBANON MOROCCO - TUNISIA - &OYPT Heating And Control Technology Via Monsagndbco I b - lOOgo Villerbessp (Torino) ITALY EMAIL info@fepa.it WEB www.fepa.it

Open the catalog to page 12