1. Catalogs
  2. FEPA Srl
  3. THERMOCOUPLES

THERMOCOUPLES

THERMOCOUPLES

THERMOCOUPLES

Product catalog summary
Application: Plastic Molding
This document outlines the specifications and applications of various thermocouples used in plastic molding processes. The thermocouples are categorized based on their design and insulation types, with specific details on dimensions, junction types, and cable specifications.
Thermocouple Types and Specifications:
  • BJ and BJF: Feature a 6x15 mm tip with a bayonet connection and a J/K type probe. They use a 2 x 0.5 mm² cable with fiberglass and metallic braid insulation.
  • FLT: Available in stem diameters of 1, 1.5, and 2 mm, with an isolated or grounded junction. It uses a J/K type probe with similar cable specifications as BJ and BJF.
  • PNT65M8 and PNT44: These have specific tip dimensions and configurations, such as a 90° bend or flange, with M8 thread connections. They also use J/K type probes with fiberglass and metallic braid insulation.
  • RNG: Features a ring with diameters ranging from 4 to 12 mm, with a grounded junction and similar probe and cable specifications.
  • SQ: Designed for hot chamber applications with a 4x12 mm tip and an isolated junction.
  • PNT414M5: Suitable for hot chamber applications, featuring a 4x14 mm tip with M5 thread connections.
MgO Insulated Thermocouples:
  • MgOBJ, MgOSt, MgOKt, MgOMn, MgOMc, MgOMi: These thermocouples have varying stem diameters and insulation materials, such as fiberglass, Kapton, and Teflon. They are designed for maximum operating temperatures of 600°C for type J and 1000°C for type K, with cable temperature limits ranging from 200°C to 400°C. Custom executions are available upon request.
Key Parameters:
  • Maximum operating temperatures: Type J - 600°C, Type K - 1000°C.
  • Cable temperature limits vary based on insulation material, ranging from 200°C to 400°C.
This document provides essential information for selecting the appropriate thermocouple based on application requirements, ensuring optimal performance in plastic molding processes.
See more

Catalog excerpts

THERMOCOUPLES-1

REV.0 del 30/11/06 doc. 7.2.10 APPLICAZIONE : STAMPAGGIO MATERIE PLASTICHE TERMOCOPPIE BJ PUNT. Dia. 6x15 MOLLA Dia. 6 mm GIUNTO ISOLATO / A MASSA RACCORDO BAIONETTA FIL ¼” GAS SONDA TIPO J/K - CAVO 2 x 0.5mmq CAVO ISOL. F.V.+TRECCIA METALLICA BJF PUNT. Dia.6x15 FLANGIA Dia. 8 mm MOLLA DIA. 8 mm GIUNTO ISOLATO / A MASSA RACCORDO BAIONETTA FIL ¼” GAS SONDA TIPO J/K - CAVO 2 x 0.5mmq CAVO ISOL. F.V.+TRECCIA METALLICA FLT STELO Dia. 1 – 1.5 – 2mm GIUNTO ISOLATO IN MgO O A MASSA SONDA TIPO J/K - CAVO 2 x 0.5mmq CAVO ISOL. F.V.+TRECCIA METALLICA PNT65M8 PUNTALE Dia. 6 x 5 mm PIEGA 90° GIUNTO ISOLATO / A MASSA RACCORDO FIL M8 SONDA TIPO J/K - CAVO 2 x 0.5mmq CAVO ISOL. F.V.+TRECCIA METALLICA PNT44 PUNTALE Dia. 4 x 4 mm CON FLANGIA Dia. 6 mm GIUNTO ISOLATO / A MASSA RACCORDO FIL M8 SONDA TIPO J/K - CAVO 2 x 0.5mmq CAVO ISOL. F.V.+TRECCIA METALLICA RNG ANELLO Dia. 4 . . . 12 mm GIUNTO A MASSA SONDA TIPO J/K - CAVO 2 x 0.5mmq CAVO ISOL. F.V.+TRECCIA METALLICA SQ PUNTALE Dia. 4 x 12 mm GIUNTO ISOLATO SONDA TIPO J/K - CAVO 2 x 0.5mmq CAVO ISOL. F.V.+TRECCIA METALLICA APPLICAZIONE SU CAMERE CALDE PNT414M5 PUNTALE Dia. 4 x 14 mm FIL M5 GIUNTO ISOLATO / A MASSA RACCORDO FIL M5 SONDA TIPO J/K - CAVO 2 x 0.5mmq CAVO ISOL. F.V.+TRECCIA METALLICA APPLICAZIONE SU CAMERE CALDE aa

 Open the catalog to page 1
THERMOCOUPLES-2

REV.0 del 30/11/06 doc. 7.2.10 APPLICAZIONE : STAMPAGGIO MATERIE PLASTICHE TERMOCOPPIE ISOLAMENTO MgO MgOBJ STELO Dia. 1,5 – 2mm GIUNTO ISOLATO / A MASSA SONDA TIPO J/K - CAVO 2 x 0. 5mmq RACCORDO A BAIONETTA CAVO ISOL. F.V. + TRECCIA METALLICA TEMP. MAX ESERCIZIO: J 600°C – K 1000°C TEMP. MAX SUL CAVO : 300°C MgOSt STELO Dia. 1 – 1,5 – 2mm GIUNTO ISOLATO / A MASSA SONDA TIPO J/K - CAVO 2 x 0.5mmq CAVO ISOL. F.V. + TRECCIA METALLICA TEMP. MAX ESERCIZIO: J 600°C – K 1000°C TEMP. MAX SUL CAVO : 300°C MgOKt STELO Dia. 1 – 1,5 – 2mm GIUNTO ISOLATO / A MASSA SONDA TIPO J/K - CAVO 2 x 0.25mmq CAVO...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.