Catalog excerpts
FPX-05 SWAP TECHNICAL FEATURES FUNCTION EXPLANATION FULL CUSTOMIZABLE P.I.D. CONTROL PROPORTION, INTEGRATION, AND DIFFERENTIATION VALUES CUSTOMIZABLE FOR FLEXIBLE SOLUTIONS DOUBLE DISPLAY IT ALLOWS TO SEE THE SET-POINT AND ALSO THE MEASURED TEMPERATURE SOFT START PRE-HEATING WITH LOW PERCENTAGE OF POWER AUTOTUNING IT ALLOWS THE SYSTEM TO GET THERMAL INERTIA OF THE LOAD TO BE CONTROLLED AND AVOID OVERTEMPERATURE RATE OF POWER IN USE YOU CAN CHECK RATE OF POWER USED AND SET IT FOR OPEN LOOP MODE OVERSHOOT CONTROL NO OVERSHOOT OCCUR CLOOSE LOOP CONTROL (AUTOMATIC MODE) YOU HAVE TO JUST SET WORKING TEMPERATURE IN THE SYSTEM OPEN LOOP CONTROL (MANUAL MODE) YOU HAVE TO SET THE PERCENTAGE OF POWER TO SUPPLY THE HEATER THERMOCOUPLE BREAK ALARM WHEN THERMOCOUPLE SIGNAL IS NOT AVAILABLE (BECAUSE THERMOCOUPLE LEADS HAS BEEN CUT OR SIMPLY THERMOCOUPLE WIRE IS NOT PROPERLY WIRED IN A CONNECTOR) IT IS IMPOSSIBLE TO WORK IN CLOSE LOOP. IT IS NECESSARY TO WORK IN OPEN LOOP WHICH MEANS MANUAL MODE : THE SYSTEM NEEDS TO SET THE DESIRED RATE OF POWER (PERCENTAGE) INVERTED THERMOCOUPLE ALARM WHEN THERMOCOUPLE WIRING IS NOT CORRECT (POSITIVE WIRE IS CONNECTED TO NEGATIVE POSITION) THE SYSTEM SUPPLY A SPECIFIC ALARM WHICH INFORMS OF THE MISTAKE. IT IS NECESSARY TO SIMPLY CHANGE THERMOCOUPLE WIRING HEATER BREAK ALARM WHEN HEATER OR FF FUSE IS BROKEN AND IT DOESN’T HEAT, SUCH ALARM INFORMS OF THE FAILURE (MAYBE THAT THE HEATER HAS TO BE CHANGED BYT MAYBE THE HEATER IS NOT WIRED CORRECTLY IN THE CONNECTOR, THEREFORE IT IS NECESSARY TO SIMPLY CORRECT WIRING) TRIAC FAILURE ALARM TRIAC IS IN SHORT CIRCUIT SWAP FUNCTION VERY IMPORTANT : AS IN CASE OF THERMOCOUPLE BREAK, THE SYSTEM SWITCHES INDEPENDENTLY FROM CLOSE LOOP TO OPEN LOOP (MANUAL MODE) AND IT CONTINUES TO WORK USING THE CORRECT RATE OF POWER CALCULATED DURING THE LAST 180 SECONDS AT SET-POINT TEMPERATURE. THIS WAY PRODUCTION IS NOT STOPPED FEPASRL VIA MONSAGNASCO, 1 BIS - 10090 VILLARBASSE (TORINO) - TEL. +390119528472 FAX +39011952048 email info@fepa.it
Open the catalog to page 1All FEPA Srl catalogs and technical brochures
-
MINITUBULAR COILED HEATERS
8 Pages
-
TEMPERATURE CONTROLLER FPX05
4 Pages
-
CARTRIDGE HEATERS
8 Pages
-
THERMOCOUPLES
9 Pages
-
Tubular heaters
12 Pages
-
NOZZLE HEATERS SNH1
1 Pages
-
TUBULAR HEATERS
2 Pages
-
WATER - OIL HEATERS
3 Pages
-
HDC MGO HI WATT BAND HEATERS
1 Pages
-
MINITUBULAR COILED HEATERS
1 Pages
-
MICA BAND HEATERS
1 Pages
-
NOZZLE HEATERS NH2
1 Pages
-
CERAMIC BAND HEATERS
1 Pages
Archived catalogs
-
THERMOCOUPLES
2 Pages
-
CARTRIDGE HEATERS
5 Pages
-
TERMOCOPPIE
1 Pages