Technical Specifications and Features of FPX-05 SWAP
Functionality: The FPX-05 SWAP is a fully customizable system with P.I.D. control, allowing for adjustable proportion, integration, and differentiation values to provide flexible solutions.
Display: It features a double display to simultaneously show the set-point and measured temperature.
Soft Start: The system includes a soft start feature for pre-heating with a low percentage of power to prevent thermal shock.
Autotuning: This feature helps the system adapt to the thermal inertia of the load, preventing overheating.
Power Management: Users can monitor and set the rate of power usage, with options for both open loop (manual mode) and closed loop (automatic mode) control.
Alarms and Safety Features:
  • Thermocouple Break Alarm: Alerts when the thermocouple signal is unavailable, necessitating a switch to open loop mode.
  • Inverted Thermocouple Alarm: Notifies incorrect wiring of the thermocouple, requiring correction.
  • Heater Break Alarm: Indicates a broken heater or fuse, suggesting a wiring check or replacement.
  • Triac Failure Alarm: Warns of a short circuit in the triac.
Swap Function: In the event of a thermocouple break, the system automatically switches from closed loop to open loop mode, maintaining production by using the power rate calculated during the last 180 seconds at the set-point temperature.
Contact Information: FEPASRL, Via Monsagnasco, 1 Bis - 10090 Villarbasse (Torino), Tel: +390119528472, Fax: +39011952048, Email: [email protected]
See more

Catalog excerpts

FPX05 TEMPERATURE CONTROLLER  DATA  SHEET-1

FPX-05 SWAP TECHNICAL FEATURES FUNCTION EXPLANATION FULL CUSTOMIZABLE P.I.D. CONTROL PROPORTION, INTEGRATION, AND DIFFERENTIATION VALUES CUSTOMIZABLE FOR FLEXIBLE SOLUTIONS DOUBLE DISPLAY IT ALLOWS TO SEE THE SET-POINT AND ALSO THE MEASURED TEMPERATURE SOFT START PRE-HEATING WITH LOW PERCENTAGE OF POWER AUTOTUNING IT ALLOWS THE SYSTEM TO GET THERMAL INERTIA OF THE LOAD TO BE CONTROLLED AND AVOID OVERTEMPERATURE RATE OF POWER IN USE YOU CAN CHECK RATE OF POWER USED AND SET IT FOR OPEN LOOP MODE OVERSHOOT CONTROL NO OVERSHOOT OCCUR CLOOSE LOOP CONTROL (AUTOMATIC MODE) YOU HAVE TO JUST SET WORKING TEMPERATURE IN THE SYSTEM OPEN LOOP CONTROL (MANUAL MODE) YOU HAVE TO SET THE PERCENTAGE OF POWER TO SUPPLY THE HEATER THERMOCOUPLE BREAK ALARM WHEN THERMOCOUPLE SIGNAL IS NOT AVAILABLE (BECAUSE THERMOCOUPLE LEADS HAS BEEN CUT OR SIMPLY THERMOCOUPLE WIRE IS NOT PROPERLY WIRED IN A CONNECTOR) IT IS IMPOSSIBLE TO WORK IN CLOSE LOOP. IT IS NECESSARY TO WORK IN OPEN LOOP WHICH MEANS MANUAL MODE : THE SYSTEM NEEDS TO SET THE DESIRED RATE OF POWER (PERCENTAGE) INVERTED THERMOCOUPLE ALARM WHEN THERMOCOUPLE WIRING IS NOT CORRECT (POSITIVE WIRE IS CONNECTED TO NEGATIVE POSITION) THE SYSTEM SUPPLY A SPECIFIC ALARM WHICH INFORMS OF THE MISTAKE. IT IS NECESSARY TO SIMPLY CHANGE THERMOCOUPLE WIRING HEATER BREAK ALARM WHEN HEATER OR FF FUSE IS BROKEN AND IT DOESN’T HEAT, SUCH ALARM INFORMS OF THE FAILURE (MAYBE THAT THE HEATER HAS TO BE CHANGED BYT MAYBE THE HEATER IS NOT WIRED CORRECTLY IN THE CONNECTOR, THEREFORE IT IS NECESSARY TO SIMPLY CORRECT WIRING) TRIAC FAILURE ALARM TRIAC IS IN SHORT CIRCUIT SWAP FUNCTION VERY IMPORTANT : AS IN CASE OF THERMOCOUPLE BREAK, THE SYSTEM SWITCHES INDEPENDENTLY FROM CLOSE LOOP TO OPEN LOOP (MANUAL MODE) AND IT CONTINUES TO WORK USING THE CORRECT RATE OF POWER CALCULATED DURING THE LAST 180 SECONDS AT SET-POINT TEMPERATURE. THIS WAY PRODUCTION IS NOT STOPPED FEPASRL VIA MONSAGNASCO, 1 BIS - 10090 VILLARBASSE (TORINO) - TEL. +390119528472 FAX +39011952048 email [email protected]

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.