HG-101 HIGH ACCURACY HUMIDITY CALIBRATOR
4Pages

{{requestButtons}}

Catalog excerpts

HG-101 HIGH ACCURACY HUMIDITY CALIBRATOR - 1

HIGH ACCURACY HUMIDITY CALIBRATOR RELATIVE HUMIDITY FROM 5 TO 95 %RH . Simple and fast operation up to 50 °C . Stability 0.2 %rh and temperature homogeneity in the test chamber 0.1 °C PATENTED RDSA TECHNOLOGY . RDSa is a unique and patented rotary flow mixing system for controlling %rh . Fast stabilization and response. Quiet operation REFERENCE HYGROMETER . Ready for MBW 473 chilled mirror integration . ISO17025 calibrated control rh sensor . Power and control through USB, PC & Android softwares included . Ability to program automated sequences (values, dwell times, ramps) MODULAR AND FLEXIBLE . Interchangeable probe ports and test cells to fit most types of instrument . Calibration of up to 7 sensors simultaneously PORTABLE . Compact and easily transportable for use on-site . Battery operation with standard USB power modules . Very low operating cost, low maintenance. . Regenerative desiccant INNOVATION IN RELATIVE HUMIDITY CALIBRATION

Open the catalog to page 1
HG-101 HIGH ACCURACY HUMIDITY CALIBRATOR - 2

HG-101 HIGH ACURACY HUMIDITY CALIBRATOR FOR ALL TYPES OF HYGROMETERS The HG-101 allows simple and rapid realization of relative humidity calibration of sensors, probes, loggers and recorders from any manufacturer. Interchangeable probe ports are available to fit most types of instrument and the measuring chamber is replaceable allowing Metrologists validate most types of measurement equipment. The standard probe test cell has 7 ports for probes up to 30mm in diameter. Test cells with up to 7 probe ports and customized solutions to suit different instrument types such as loggers with...

Open the catalog to page 2
HG-101 HIGH ACCURACY HUMIDITY CALIBRATOR - 3

USB – SOFTWARE Thanks to the USB port and the software for Android and Windows, it is possible to automate calibration, reducing operator time. With the software’s programmer function, the user has the possibility to create sequences containing up to 10 points, with variable dwell times. measurment chamber / test cell dessicant cartridge saturator cartridge Manual control REFERENCE CHILLED MIRROR HYGROMETER PATENTED RDSA TECHNOLOGY The RDSa rotary dilution system is specifically developed and patented to allow the relative humidity generator HG-101 to control the relative humidity with high...

Open the catalog to page 3
HG-101 HIGH ACCURACY HUMIDITY CALIBRATOR - 4

HG-101 HIGH ACURACY HUMIDITY CALIBRATOR HG-101 generator operates in a closed loop, so it is particularly economical in terms of desiccant and distilled water consumption. Users can recycle the desiccant by regeneration in an oven at 130 °C. Internal cleaning when needed can be easily performed. These factors mean the HG-101 has extremely low operating costs. The HG-101 calibrator RDSa humidity control system includes desiccant and humidifying cartridges that are easily removed and simple for the user to maintain, even whilst generating humidity. When performance diminishes, the user can...

Open the catalog to page 4