video corpo

Mobilis INNO

Mobilis INNO
1 / 48 PagesView full catalog

Mobilis INNO

Product catalog summary
Overview
The Mobilis Inno electrical supply rail is engineered for mobile equipment such as travelling cranes, prioritizing safety, compactness, quick assembly, reliability, and ease of maintenance. It features a closed profile with IP23 protection, suitable for use in rainy conditions, and supports rapid installation with clip-on accessories, reduced voltage drop, and high operational reliability.
Technical Specifications
The system is available in 40A and 60A intensities, with a maximum operating voltage of 690V. It functions in temperatures ranging from -30°C to +55°C and supports a maximum trolley speed of 60m/min. It is suitable for both indoor and outdoor applications, maintaining a protection level of IP23.
Standards and Safety
The Mobilis Inno complies with standards EN61439-1, EN61439-6, and EN60204-32. It incorporates self-extinguishing materials and a safety pin system to prevent incorrect trolley insertion. Additional safety measures are recommended for public areas.
Installation and Maintenance
The system facilitates easy installation with modular components, eliminating the need for conductor preparation. Maintenance involves regular inspections of conductors and trolleys, with a recommended service schedule after 2,000 km or one year of use.
Environmental Considerations
Designed for mild outdoor conditions, the system can be adapted for harsher environments with the Mobilis Elite range. It includes features to minimize environmental impact, such as reduced packaging and easy maintenance.
Additional Features
The system includes innovative junction connections, modular product lengths, and optimized carrier intensity for crane applications. It also offers line calculation software for determining required intensity and voltage drop management through strategic feed box placement.
Components and Installation
  • Standard Straight Element: Modular with integrated copper conductors, available in various lengths, rated for 690V, and made from self-extinguishing PVC and copper.
  • Ventilation Element: Limits condensation, suitable for high humidity environments, and requires specific installation spacing.
  • Clipped Junction Connection: Ensures continuity between elements, quick assembly, and low voltage drop.
  • Feeding Connection: Connects power cables, available for in-line or end-line configurations.
  • Covering Flange: Provides insulation and protection for junctions, clip-on assembly.
  • End-Cap: Insulates live elements at line ends, ensuring safety.
  • Sliding and Fixed Hangers: Support line and allow expansion, with specific installation requirements.
  • Feed Boxes: Provide electrical connections, reduce voltage drop, and accommodate line expansion.
Voltage Drop and Mounting Rules
Emphasizes the importance of considering voltage drop in installations, especially with multiple feeding points, and specifies the use of flexible cable loops and contact lubricant for aluminum cables.
Trolleys and Carriers
  • Rigid Trolleys: Designed for straight installations, available in versions handling up to 70A, featuring self-lubricating carbon brushes.
  • Carrier and Mounting: Ensures mechanical linkage between trolley and device, with large clearance and proper alignment for longevity.
  • Carrier with Box: Provides mechanical and electrical connection, requiring proper installation space.
Additional Components
  • Switching Finger: Detects end positions in cranes, adjustable and fits onto the line.
  • Bracket: Maintains line distance, available in various lengths, suitable for interior use.
  • Cleaning Trolley: Cleans conductors, restoring contact quality and preventing brush wear.
  • Replacement Parts: Include collector and cleaning brushes for maintenance.
Guarantee
The equipment is guaranteed for one year against material or manufacturing defects, covering only replacement or repair of defective parts, with no liability for installation, operation, or production stoppages.
See more

Catalog excerpts

Mobilis INNO-1

Electrical supply rail

 Open the catalog to page 1
Mobilis INNO-2

Contents Presentation

 Open the catalog to page 2
Mobilis INNO-3

Presentation The electrical supply rail Mobilis Inno meets the requirements of the most demanding manufacturers, installers, and end-users of mobile equipment: safety, compact, fast assembling, operation reliability, and easy maintenance of this electrical supply rail for travelling cranes and other mobile equipment requiring mobile power socket. EXCELLENT SAFETY AND OPERATOR PROTECTION: The closed profile of the mounted line with the full set of accessories has a protection level of IP23, which means that the equipment is protected so that people cannot access the dangerous sections, even under...

 Open the catalog to page 3
Mobilis INNO-4

BENEFITS : New range inspired from MOBILIS ELITE: Safety High rank of design and performance Easier to install, to use and to maintain Design and brand color respected (clear grey profile, yellow accessories) Economicaly optimized Self-supporting PVC Profile with optimized cellular structures, closed, design and compact, for a minimal weight (Mobilis was the first to introduce the cellular PVC profiles on the market. The INNO profile is 35% more compact than the ELITE) Floating conductors fitted inside the profile to take into account the expansion differences of line’s synthetic material....

 Open the catalog to page 4
Mobilis INNO-5

Technical data 1. USE The electrical supply rails with mobile socket Mobilis INNO are generally used for the electrification of Systems with straight trajectory like travelling cranes, cranes and hoists, narrow-aisle stores, work station equipment (tasksaver systems), elements of electric hoisting equipment and other diverse applications, inside and outside. 2. GENERAL TECHNICAL DATA: Rated operational intensity: The MOBILIS INNO lines are available in rated intensities 40A and 60A. The real current capacity depends on the operating factors and the ambient temperature. Number of poles: 4 poles...

 Open the catalog to page 5
Mobilis INNO-6

6. INSULATION DISTANCES: Insulation distance between conductors or between conductors and accessible parts: - Distance in the air: 10 mm min, adapted to overvoltage category No. III ie 6kV according to EN61439-1. - Creepage distance: 30 mm min. (according to EN60204-32) 7. FLAME RESISTANCE: All materials used to build Mobilis INNO lines are self-extinguishing; they pass successfully glowing/hot line tests under 960°C for elements in contact with live parts and V-0 according to UL-94. 8. SAFETY PINS Line: identification of ground conductor: The ground conductor (PE) is marked on the whole line’s...

 Open the catalog to page 6
Mobilis INNO-7

Intensive running: See the maximum intensity for a 100% duty cycle in the next paragraph. 12. INTENSITY ACCORDING TO DUTY CYCLE: 13. PROTECTION AGAINST SHORT-CIRCUITS: For intensities 40A and 60A, Icw<10kA. 14. LIGNE CALCULATION This paragraph gives a diagram to calculate the intensity required for your application: select your line’s length and check that for each rating, the rated current required by your motor is supported by the line. VOLTAGE DROP ACCORDING TO THE POSITION OF FEED BOXES A judicious arrangement of the supply points makes it possible to reduce the voltage drop. Positioning...

 Open the catalog to page 7
Mobilis INNO-8

Example: an in-line feed box halves the length Lt of the section to be considered on the diagram. In this case, a 60A line of 160m with a feed box in the middle accepts a current of 60A with a voltage drop of less than 3%. One feed box at the end of the line Three feed boxes One feed box on line Four feed boxes Two feed boxes

 Open the catalog to page 8
Mobilis INNO-9

1) General points Any intervention must be carried out offline only. Maintenance primarily concerns the conductors and the trolleys. Any damage to the conductors will reduce the operating life of the brushes. This damage may take different forms: - Oxidation due to a chemical environment - Abrasive dust - Damage due to electrical arcs in the case of a faulty contact following oxidation, heavy soiling or use of worn brushes. Regular inspection is required to check the wear of the brushes, casters of wheels and the quality of the conductive tracks according to the rate of use, the distance covered,...

 Open the catalog to page 9
Mobilis INNO-10

1-Standard straight element Modular straight element of predefined length with 4 integrated copper conductors Advantages Ends ready to receive their connections. Compact and rigid. Description Modular element which ensures the transmission of the current and the guidance of the collector trolleys. Green-yellow protective conductor identification strip over the entire length. Product number and compatibilities The standard straight elements are available with varying lengths of 4m, 3m, 2m, 1m and special length. The intensities indicated are valid for 50Hz, 60Hz and D.C. Technical data Standard...

 Open the catalog to page 10
Mobilis INNO-11

Material Self-extinguishing and lead-free PVC color light grey, copper Mounting Installation rules After installing the suspension parts, clip the straight elements one behind the other in the sliding suspensions, keeping a distance of 0.35m between the first suspension and the end of the first element. Connect the ends of the conductors by using the independent connections (reference: MI1000). Mounting rules 1. Insert the lines in the sliding hangers, 2. Connect the lines Mounting and dismounting required tools

 Open the catalog to page 11
Mobilis INNO-12

2-Ventilation element Limits condensation in a line with a warm section (interior) and a cold section (exterior) of a building. Advantages Limits condensation Available in 2 lengths Description The purpose of the ventilation element is to limit condensation in a line with a warm section (inside the factory) and a cold section (outside the factory). In case of high humidity (working process using water, presence of animals, etc.) prefer Mobilis Elite with the possibility of rubber gasket. Product number and compatibilities Technical data Overall dimensions

 Open the catalog to page 12
Mobilis INNO-13

Mounting Installation rules The ventilation element is to be fitted like a standard element at the exit of the building (at the start of the cold area). The edge of the PVC cap must stand in the cold area at a distance of 200 to 500 mm from the warm area. Provide 2 sliding hangers, with a center axis distance of 500mm for a 1m element, and of 2m for a 4m element. Mounting rules Same as the right element 1. Insert the ventilation element into the suspensions, 2. Connect the ventilation. Mounting and dismounting required tools

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.