Specifications:
The G-LED Global Series Signaling Platform is available in 24VDC and 120-240VAC 50/60Hz configurations. It features a long-life LED with selectable flash patterns and two lens options (low or high-profile). The device is rated for 'Ex op is' protection and is made from corrosion-resistant GRP, suitable for offshore and industrial applications. It includes M20 entries, with an M25 option available, and is IP66 and IP69K compliant.

Features:
- Eight flash patterns with a default of 60 FPM.
- Auto-sync for AC flashing patterns.
- Optional indicator rings in six colors.
- Field customizable legend plates.
- UL and cUL listed for various hazardous location ratings.

Certifications:
- ATEX/IECEx: Ex db e op is IIC Gb, Ex tb IIIC Db IP66.
- UL/cUL: Class I, Division 2, Groups A, B, C, D T4; Class II, Division 2, Groups F, G T6; Class III T6.

Mounting Options:
- Ex d Surface Mount
- Ex d U-Bracket Mount
- Ex de Surface Mount

Ordering Information:
Available in various colors (Amber, Blue, Clear, Green, Magenta, Red, Yellow) and configurations (Ex d, Ex de). Replacement parts and accessories are available, including internal sub-assembly kits and mounting adapters.

Dimensions and Weight:
- Low-Profile: 6.17 lbs (Ex d Surface Mount)
- High-Profile: 6.67 lbs (Ex d Surface Mount)

Applications:
The G-LED is ideal for alarm control panel applications and can be combined with other Global Series products for custom configurations.
See more

Catalog excerpts

Model G-LED-1

► Model G-LED c Y Global Series® Signaling Platform - LED Federal Signal's patented Global Series® LED Beacons feature a long-life LED with the ability to select one of eight (8) flash patterns (user-configurable) and offers two lens options (low or high-profile). The device is rated to the latest protection concept, "Ex op is" (inherently safe optical radiation). The housing is made from GRP (Glass Reinforced Polyester) designed to serve the demanding needs of offshore marine and land-based industrial applications. The Global Series LED Beacons flameproof "Ex d" versions come standard with two (2) M20 entries. The increased safety "Ex de" versions include a separate terminal chamber for quick field termination or pass-through wiring, and includes three (3) M20 entries in a standard configuration. These units can be combined with other Global Series products to create factory direct custom configurations, or optional coupling kits are available for limited field fixturing. The Global Series LED Beacon is ideal for use in alarm control panel applications. Available in 24VDC and 120-240VAC 50/60Hz Optional 316 stainless steel ratchet adjustable mounting U-bracket (field installation required) GRP (Glass Reinforced Polyester) Non-metallic corrosion resistant design Two lens options: low- or high-profile Dome guard included 24VDC models contain a supervisory diode and four wire terminal block M20 entries standard (M25 option available) LED has 8 on-board flash patterns, factory default is flashing at 60 FPM "Auto-sync" available for AC flashing pattern products2 Optional indicator rings are available in six colors: Black, Blue, Green, Magenta, Red and Yellow Field customizable legend plates available1 Type 4X, IP66 enclosure IP69K compliant Zone 1, 21 Rated, lECEx, ATEX, Ex d IIC, Ex de IIC and Ex tb IIIC UL and cUL Listed for Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Class III UL and cUL Listed for Class I, Zone 1 AEx db IIC and Zone 21, AEx op is tb IIIC T200°C, excludes increase safety versions (Ex de) UL/cUL HAZARDOUS LOCATION RATING UL/cUL HAZARDOUS LOCATION CLASS/ZONE TEMPERTURE CODE AT 70°C Class I, Division 2, Groups A, B, C, D T4 Class II, Division 2, Groups F, G T6 T4 ATEX/IECEx HAZARDOUS LOCATION RATING TEMPERTURE CODE AT 70°C/58°C T5/T6 1 Recommended labels: BRADY #B-855 Toughwash labels or ULINE #S-16643 weather resistant 2 Consult our Technical Support team for details

 Open the catalog to page 1
Model G-LED-2

VISUAL SIGNALS REPLACEMENT PARTS Lamp Life: 50,000 Hours Nominal Operating Temperature Range: -67°F to 158°F -55°C to 70°C ATEX/IECEx Certification Marking: II 2GD Ex db e op is IIC Gb,Ex tb IIIC Db IP66. T6 @ 58°C; T5 @ 70°C II 2GD Ex de IIC Gb, Ex tb IIIC Db IP66. T6 @ 58°C; T5 @ 70°C ATEX: Baseefa15ATEX0153X IECEx: IECEx BAS 15.0102X Guard and External Fasteners: 316 stainless steel Ex de: 3-pole, 4 position quad pole terminal blocks Cable Entries: Ex d: 2 entries - M20 x 1.5 UL and cUL Certification Marking: Class I, Division 2, Groups A, B, C, D Class II, Division 2, Groups F, G Class III...

 Open the catalog to page 2

All FEDERAL SIGNAL catalogs and technical brochures

  1. Model G-MSC-2

    4  Pages

  2. Model G-STR

    2  Pages

  3. Model 225XL-N

    2  Pages

  4. UniStat

    2  Pages

  5. StreamLine®

    7  Pages

  6. Model DSA1

    2  Pages

  7. Informer-IP

    2  Pages

  8. TS100-N

    2  Pages

  9. Rumbler

    2  Pages

  10. MS4000 Series

    2  Pages

  11. PA300

    2  Pages

  12. SW400

    2  Pages

  13. COMFL

    2  Pages

  14. SLM400/SLM450

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.