Open the catalog to page 1Type Tested Panel 1 Electrical - Mechanical Characteristics 4 Please ask for a panel catalogue for further information.
Open the catalog to page 2Federal Electric has taken type tests for the panels that it has produced. The experiments have been made in IHP Laboratories and Bogazigi University high current laboratories by the English Certification Institute ASTA observers. While the inputs and the outputs in the Federal Type Tested Panel can be made over or under the panel according to the needs of the system, it provides the opportunity of making the cable or the bus bar connections from front or rear of the panel. As the panels have been completely designed in modular structure by means of their screw combinations changes can be...
Open the catalog to page 3Sample type tasted panel boardPANEL-1 PANEL-2 2350 2350
Open the catalog to page 5Federal Electric modular panels are designed and manufactured in accordance with energy distributing, controlling and monitoring purposes. As they are designed completely modular, you may make amendments and / or expand them by adding modules thanks to their screwed joints. They allow easy equipment assembly thanks to wide variety of accessories. They are dispatched as assembled to Federal Electric products depending on your projects. They are resistant to dynamic forces formed during opening-closing maneuvers of breakers with high breaking capacity thanks to their solid composition. Thanks...
Open the catalog to page 6FMP-1 panels have two kinds of assembly elements as if required. Door directions may be reversed without any aluminum casting corner (A1) and sheet corner (A2). It is problem in piece covers when you instruct so, however, door completely bolted and in modular form. Panel depth can be direction should be instructed at ordering stage for single used as width and width can be used as depth in the piece door (OK3). framework. Opening door can be used as well as cover on the side edge. Our doors open towards left. They might open towards right,
Open the catalog to page 7FMP-2 panels have two kinds of assembly elements as aluminum casting corner (A1) and sheet corner (A2). It is completely bolted and in modular form. Panel depth can be used as width and width can be used as depth in the framework. Opening door can be used as well as cover on the side edge. Our doors open towards left. They might open towards right, if required. Door directions may be reversed without any problem in piece covers when you instruct so, however, door direction should be instructed at ordering stage for single piece door (OK3).
Open the catalog to page 8Front view Side view Side view
Open the catalog to page 9OKI: Front cover (with glass) X Note: In piece covers in OK2, parts no (212 and 204) can be variable provided that the dimension 1650 mm remains fixed.
Open the catalog to page 10All Federal Elektrik catalogs and technical brochures
-
ANALYZER
11 Pages
-
20 relays
6 Pages
-
BMC (Bulk Moulding Compaund)
3 Pages
-
NATURAL GAS METERS
22 Pages
-
ELECTRONIC BALLASTS
34 Pages
-
FUSE SWITCH DISCONNECTORS
14 Pages
-
NH FUSES and BASES
8 Pages
-
THERMAL OVERLOAD RELAYS
6 Pages
-
SURGE PROTECTIVE DEVICE
8 Pages
-
INSTALLATION CONTACTORS
4 Pages
-
MOLDED CASE CIRCUIT BREAKERS
54 Pages
-
Molded Circuit Breakers
54 Pages
-
Air Type Circuit Breakers
14 Pages
-
NH (H.R.C) Fuses
8 Pages
Archived catalogs
-
NH (H.R.C) Fuses
9 Pages
-
Contactors
22 Pages
-
Natural gas meters
17 Pages
-
Control unit heating system
3 Pages
-
Modular panel system
7 Pages
-
Easypan Distribution Boards
11 Pages
-
Electronic Energy Meters
6 Pages
-
Measurement Devices
12 Pages
-
Reactive Relays
10 Pages
-
Power capacitors
7 Pages
-
Relays
7 Pages
-
Motor protection switches
5 Pages
-
Smart relays
5 Pages
-
Thermal relays
5 Pages
-
Cam switches
5 Pages
-
Current transformers
8 Pages
-
Miniature circuit breakers
8 Pages
-
Vertical type switch fuses
5 Pages
-
Load Break Switch
9 Pages
-
Air Type Circuit Breakers
15 Pages
-
L_V_Circuit_Breakers
53 Pages