Catalog excerpts
LOAD BREAK SWITCHES WITH and WITHOUT FUSE
Open the catalog to page 1Load Break Switches with Fuse Composition of Load Break Switched Load Break Switch with Fuse Technical Specification Order Codes Load Break Switch without Fuse Technical Specification Order Codes Change-over Isolation Switch Technical Specification Order Codes Order Codes Technical Drawings Load Break Switches without Fuse Change-over Isolation Switch Mounting Position Relative Humidity Ambient Temperature Pollution Degree Protection Degree Utilization Category All these given Information are general. We have always right to change them.
Open the catalog to page 2LOAD BREAK SWITCHES WITH and WITHOUT FUSE Rotating contact system (for 250A, 400A, 630A) protective load break Fig - 2 switch with fuse Federal Electric load break switches are quite useful compact devices with capability of breaking at two separate points on the same phase with sudden opening-closing. They provide space economy in tables and panels they are Load break switched are manufactured in accordance with CE, according to in compliance with AC 23 class. They are safely used for switching purposes in motor circuits and AC-DC systems. -High breaking capacity -High electrical and...
Open the catalog to page 3LOAD BREAK SWITCHES WITH and WITHOUT FUSE Load Break Switch With Fuse: Technical Specifications: □field is for writing number of poles (3 or 4). Load break switch with fuse are dispatched without NH fuse.
Open the catalog to page 4LOAD BREAK SWITCHES WITH and WITHOUT FUSE Load Break Switch Without Fuse: Technical Specifications: □ field is for writing number of poles (3 or 4).
Open the catalog to page 5LOAD BREAK SWITCHES WITH and WITHOUT FUSE Change-over Isolation Switch (Vertical Installed): Technical Specifications: □ field is for writing number of poles (3 or 4).
Open the catalog to page 6LOAD BREAK SWITCHES WITH and WITHOUT FUSE Change-over Isolation Switch (Horizantal Installed): Technical Specifications: □ field is for writing number of poles (3 or 4).
Open the catalog to page 7LOAD BREAK SWITCHES WITH and WITHOUT FUSE - Auxiliary contact block: 1NO + 1NC, 2NO + 2 NC - Terminal protective cover (Pic-2) - Special lock and padlock system - Cage type connector Note: Terminal protective cover provides safe insulation in accordance with EN norms, by avoiding had contact of cable connection terminals and fuse connection sections of load Pic - 2 Terminal protective cover Terminal protective cover order codes: For types without fuse Control lever: Control shaft: Panel connection hole dimensions:
Open the catalog to page 8LOAD BREAK SWITCHES WITH and WITHOUT FUSE Load Break Switch With Fuse: Back Connection Type of Control Lever ----Shown parts with discrete lines are manufactured as per customer request.
Open the catalog to page 9LOAD BREAK SWITCHES WITH and WITHOUT FUSE Load Breakers With Terminal Cover: Back Connection Terminal Type of Control Lever - Shown parts with discrete lines are manufactured as per customer request.
Open the catalog to page 10LOAD BREAK SWITCHES WITH and WITHOUT FUSE Change-over Isolation Switch (Vertical Installed):
Open the catalog to page 11LOAD BREAK SWITCHES WITH and WITHOUT FUSE Change-over Isolation Switch (Horizantal Installed):
Open the catalog to page 12LOAD BREAK SWITCHES WITH and WITHOUT FUSE Terminal Cover: Protective Cover:
Open the catalog to page 13All Federal Elektrik catalogs and technical brochures
-
ANALYZER
11 Pages
-
20 relays
6 Pages
-
BMC (Bulk Moulding Compaund)
3 Pages
-
NATURAL GAS METERS
22 Pages
-
ELECTRONIC BALLASTS
34 Pages
-
FUSE SWITCH DISCONNECTORS
14 Pages
-
NH FUSES and BASES
8 Pages
-
THERMAL OVERLOAD RELAYS
6 Pages
-
SURGE PROTECTIVE DEVICE
8 Pages
-
INSTALLATION CONTACTORS
4 Pages
-
MOLDED CASE CIRCUIT BREAKERS
54 Pages
-
Molded Circuit Breakers
54 Pages
-
Air Type Circuit Breakers
14 Pages
-
NH (H.R.C) Fuses
8 Pages
Archived catalogs
-
NH (H.R.C) Fuses
9 Pages
-
Contactors
22 Pages
-
Natural gas meters
17 Pages
-
Control unit heating system
3 Pages
-
Modular panel system
7 Pages
-
Easypan Distribution Boards
11 Pages
-
Electronic Energy Meters
6 Pages
-
Measurement Devices
12 Pages
-
Reactive Relays
10 Pages
-
Power capacitors
7 Pages
-
Relays
7 Pages
-
Motor protection switches
5 Pages
-
Smart relays
5 Pages
-
Thermal relays
5 Pages
-
Cam switches
5 Pages
-
Current transformers
8 Pages
-
Miniature circuit breakers
8 Pages
-
Vertical type switch fuses
5 Pages
-
Load Break Switch
9 Pages
-
Air Type Circuit Breakers
15 Pages
-
L_V_Circuit_Breakers
53 Pages