FUSE SWITCH DISCONNECTOR
Open the catalog to page 1Vertical Type Fuse Switch Technical Drawings Technical Table Vertical Type Fuse Bases Fuse Switch Disconnector VERTICAL TYPE FUSE FUSE SWITCH FUSE SWITCH Mounting Position Relative Humidity Ambient Temperature Pollution Degree Protection Degree Over Voltage Class
Open the catalog to page 2VERTICAL TYPE FUSE SWITCH DISCONNECTOR Federal Electric vertical type switch fuses accordance with EC 60947-3 standard according to CE. Federal FVS vertical type switch fuses are used in electricity distribution for protection against short - Each pole may open-close independently from other poles and all simultaneously with a single lever if - It is designed to assemble in vertical position to horizontal busbars. - Wear-out of contacts as a result of opening-closing under load is avoided - They have high short circuit breaking - They are easy to assemble. - They have high electrical and...
Open the catalog to page 3VERTICAL TYPE FUSE SWITCH DISCONNECTOR 3 3- Fuse holder 4- Terminal Cover (optional) 5- Bolt M8x20 6- Bridge clamps (optional) 7- Circle sliced clamps (optional) 8- Hook clamps (optional) 9- Micro switch (optional) Accessories Order Code Terminal cover It is used to prevent touching thru connection terminals. Bridge clamps Used to connect wires with cross section between 4 to 70 mm2 by two M5 bolts Circle sliced clamps Used to fixedwire of sector shoped condustor with bore and cross-section 1,5 - 70 mm2 by two M5 bolts. Hook clamps Micro switch Used to assemble the body directly to the bar....
Open the catalog to page 4VERTICAL TYPE FUSE SWITCH DISCONNECTOR 160A Vertical Type Switch Fuses Three phase can open individual. Type FVS160 Product Structure NH Fuse Type / Size Order Code Three phase can open individual. NH00 / NH000 9BE-E1213-0160 205 137 160A Vertical Type Switch Fuses Three phase can open together Type FVS160 Product Structure NH Fuse Type / Size Three phase can open together NH00 / NH000 212 147 137
Open the catalog to page 5(*) 210mm distance for connection is also available 250A - 400A - 630A Vertical Type Switch Fuses Three phase can open together Product Structure NH Fuse Type / Size NH1 / NH2 Three phase can open together NH1 / NH2 / NH3 NH1 / NH2 / NH3 (*) 210mm distance for connection is also available
Open the catalog to page 6VERTICAL TYPE FUSE SWITCH DISCONNECTOR 250A - 400A - 630A Vertical Type Switch Fuses With left side output three phases can be opened separately Type FVS250-LS FVS400-LS FVS630-LS Product Structure With left side output three phases can be opened separately (*) 210mm distance for connection is also available 250A - 400A - 630A Vertical Type Switch Fuses With left side output three phases can be opened together Type FVS250-LS FVS400-LS FVS630-LS Product Structure Wth left side output three phases can be opened together (*) 210mm distance for connection is also available
Open the catalog to page 7VERTICAL TYPE FUSE SWITCH DISCONNECTOR 250A - 400A - 630A Vertical Type Switch Fuses With right side output single phase can be opened separately Type FVS250-RS FVS400-RS FVS630-RS Product Structure With right side output single phase can be opened separately (*) 210mm distance for connection is also available 250A - 400A - 630A Vertical Type Switch Fuses With right side output single phase can be opened together Type Rated Current (A) Product Structure FVS250-RS 250 With right side output single FVS400-RS 400 phase can be opened FVS630-RS 630 together (*) 210mm distance for connection is...
Open the catalog to page 8VERTICAL TYPE FUSE SWITCH DISCONNECTOR Symmetrical Design In case of cable input is from above,Vertical Type Switch Fuse was design symmetrical as the body is suitable to turn 180°. Mounting Diagram for Vertical Type Switch Fuses With Outputs at Side Main busbar Distribution busbar Output at side busbar Output at side busbar Main busbar Main circuit breaker
Open the catalog to page 9VERTICAL TYPE FUSE SWITCH DISCONNECTOR Micro Switch Sealing Posibility Sealing is possible in the aim of guarantee of fuse holder can not opened 1 or 2 micro switch is available assembled to each phase is possible to control open and closed position of fuses holder. Additional Output Apparatus Through the window capable to open and close placed on front of fuse holder,there is a posibility to get additional output as size 00 with optional additonal output apparatus for necessary situation. Measurement under the voltage is posibble. Through the holes on the fuse holders, there is the...
Open the catalog to page 10VERTICAL TYPE FUSE SWITCH DISCONNECTOR Conventional thermal current (Ith) Number of poles Insulation voltage (Ui) Impulse withstand voltage (Uimp) Operational voltage (Ue) (phase-phase) Conditional short-circuit current (NH Fuse) kA Mechanical durability Electrical durability Fuse type Connection conductor cross-section Power loss per pole Max- Min tightening torques Distance between main busbar terminals mm Hole diameter The designation of utilization categories is completed by the suffix A or B according to whether the intended applications require· frequent or infrequent operations....
Open the catalog to page 11VERTICAL TYPE FUSE SWITCH DISCONNECTOR VERTICAL TYPE FUSE BASES; Federal Electric Vertical Type Fuse Bases have been designed in a manner that they can be easily and fast assembled vertically to the horizontal bus bars in 185 mm / 210 mm distances. The body material has been produced from glass fiber polyester resin (BMC) that belongs to thermoset material and its dielectric and mechanic features are very high. It is resistant to flame and heat. The contacts that are used in the fuse bases have been produced from electrolytic copper, and they have been covered with silver. The covers that...
Open the catalog to page 12FUSE SWITCH DISCONNECTOR FUSE SWITCH DISCONNECTOR: They are very safety and practical devices to protect system by sudden-off and equipment in box type. It is being provided by NH00 size. Fuse Switch Disconnectors are being produced IEC 609473 Standard and providing you to more practical working spaces over tables, panels and places, easy to use and protection for life and materials. In order ensure a long durability lifespan, the Fuse Switch Disconnectors are manufactured with reinforced thermoplastic materials and flame retardant. Additionaly, they feature contacts with silver coating,...
Open the catalog to page 13All Federal Elektrik catalogs and technical brochures
-
ANALYZER
11 Pages
-
20 relays
6 Pages
-
BMC (Bulk Moulding Compaund)
3 Pages
-
NATURAL GAS METERS
22 Pages
-
ELECTRONIC BALLASTS
34 Pages
-
NH FUSES and BASES
8 Pages
-
THERMAL OVERLOAD RELAYS
6 Pages
-
SURGE PROTECTIVE DEVICE
8 Pages
-
INSTALLATION CONTACTORS
4 Pages
-
MOLDED CASE CIRCUIT BREAKERS
54 Pages
-
Molded Circuit Breakers
54 Pages
-
Air Type Circuit Breakers
14 Pages
-
NH (H.R.C) Fuses
8 Pages
Archived catalogs
-
NH (H.R.C) Fuses
9 Pages
-
Contactors
22 Pages
-
Natural gas meters
17 Pages
-
Control unit heating system
3 Pages
-
Modular panel system
7 Pages
-
Easypan Distribution Boards
11 Pages
-
Electronic Energy Meters
6 Pages
-
Measurement Devices
12 Pages
-
Reactive Relays
10 Pages
-
Power capacitors
7 Pages
-
Relays
7 Pages
-
Motor protection switches
5 Pages
-
Smart relays
5 Pages
-
Thermal relays
5 Pages
-
Cam switches
5 Pages
-
Current transformers
8 Pages
-
Miniature circuit breakers
8 Pages
-
Vertical type switch fuses
5 Pages
-
Load Break Switch
9 Pages
-
Air Type Circuit Breakers
15 Pages
-
L_V_Circuit_Breakers
53 Pages